Datasheet

Find us at www.keysight.com Page 3
Leading technology in a value-priced oscilloscope (DSOX models)
Keysight’s InfiniiVision 1000 X-Series oscilloscopes are engineered to give you quality, industry-proven
technology at unbelievably low prices. Now it’s easy to get professional measurements and accessible expertise
at your fingertips. Don’t settle for less and test to impress.
70 to 200 MHz bandwidth (DSOX models)
Frequency response analysis (Bode gain & phase plots), included in models with WaveGen
See more signal detail with 200,000 waveforms/sec update rate
Have confidence in your measurements with Keysight-custom technology that leverages more than
60 years of oscilloscope expertise
Test quickly and easily with a simple, intuitive user-interface and built-in help and training signals
Get professional-level functionality with industry-leading software analysis including standard serial
bus analysis for the most popular serial bus standards, and 6-in-1 instrument integration
DSOX1202A
2 channels
DSOX1202G
2 channels
with function generator
DSOX1204A
4 channels
DSOX1204G
4 channels with
function generator
Bandwidth
100 MHz (D1202BW1A)
70 MHz (base bandwidth)….
100 MHz (D1200BW1A)
200 MHz (D1200BW2A)
Analog channels
4
External trigger
(Displayable as a 3rd digital channel)
Back panel input
(not displayed)
Sample rate per channel
(max)
2 GSa/s (one- or half-channel
1
operation)..
1 GSa/s (three- or four-channel operation)
Memory depth per channel
(max)
2 M points (one- or half-channel
1
operation).
1 M points (three- or four-channel operation)
WaveGen
Not available
20-MHz function generator
Not available
20-MHz function generator
Bode plot
Not available
Standard
Not available
Standard
Waveform update rate
200,000 waveforms per second
Serial protocol analysis
Standard : I²C, SPI, UART/RS-232, CAN, LIN
Segmented memory
Standard
Mask/limit testing
Standard
Built-in training signals
Standard
Integrated digital voltmeter
Standard
Frequency counter
Standard
Waveform math
Add, subtract, multiply, divide, FFT (magnitude and phase), low pass filter
Automatic measurements
14 amplitude, 14 timing, and 4 pulse count measurements
Display
7-inch TFT LCD WVGA
Connectivity
USB 2.0 (host and device), LAN
1. Half-channel operation on a 4-channel model refers to two-channel operation when using channel-1 or channel-2 AND
channel-3 or channel-4. Example: If viewing just channel-1 and channel-3, maximum sample rate is 2 GSa/s and maximum
memory is 2 M poi nts. But if viewing channel-1 and channel-2, maximum sample rate is 1 GSa/s and maximum memory is 1 M
points.