Datasheet
Find us at www.keysight.com Page 3
Leading technology in a value-priced oscilloscope (DSOX models)
Keysight’s InfiniiVision 1000 X-Series oscilloscopes are engineered to give you quality, industry-proven
technology at unbelievably low prices. Now it’s easy to get professional measurements and accessible expertise
at your fingertips. Don’t settle for less – and test to impress.
– 70 to 200 MHz bandwidth (DSOX models)
– Frequency response analysis (Bode gain & phase plots), included in models with WaveGen
– See more signal detail with 200,000 waveforms/sec update rate
– Have confidence in your measurements with Keysight-custom technology that leverages more than
60 years of oscilloscope expertise
– Test quickly and easily with a simple, intuitive user-interface and built-in help and training signals
– Get professional-level functionality with industry-leading software analysis including standard serial
bus analysis for the most popular serial bus standards, and 6-in-1 instrument integration
DSOX1202A
2 channels
DSOX1202G
2 channels
with function generator
DSOX1204A
4 channels
DSOX1204G
4 channels with
function generator
Bandwidth
70 MHz (base bandwidth)…..
100 MHz (D1202BW1A)
200 MHz (D1202BW2A)
70 MHz (base bandwidth)….
100 MHz (D1200BW1A)
200 MHz (D1200BW2A)
Analog channels
2
4
External trigger
Front panel input
(Displayable as a 3rd digital channel)
Back panel input
(not displayed)
Sample rate per channel
(max)
2 GSa/s (one- or two-channel operation)……
1 GSa/s (if external trigger view is turned on)
2 GSa/s (one- or half-channel
1
operation)..
1 GSa/s (three- or four-channel operation)
Memory depth per channel
(max)
2 M points (one- or two-channel operation)……
1 M points (if external trigger view is turned on)
2 M points (one- or half-channel
1
operation).
1 M points (three- or four-channel operation)
WaveGen
Not available
20-MHz function generator
Not available
20-MHz function generator
Bode plot
Not available
Standard
Not available
Standard
Waveform update rate
200,000 waveforms per second
Serial protocol analysis
Standard : I²C, SPI, UART/RS-232, CAN, LIN
Segmented memory
Standard
Mask/limit testing
Standard
Built-in training signals
Standard
Integrated digital voltmeter
Standard
Frequency counter
Standard
Waveform math
Add, subtract, multiply, divide, FFT (magnitude and phase), low pass filter
Automatic measurements
14 amplitude, 14 timing, and 4 pulse count measurements
Display
7-inch TFT LCD WVGA
Connectivity
USB 2.0 (host and device), LAN
1. Half-channel operation on a 4-channel model refers to two-channel operation when using channel-1 or channel-2 AND
channel-3 or channel-4. Example: If viewing just channel-1 and channel-3, maximum sample rate is 2 GSa/s and maximum
memory is 2 M poi nts. But if viewing channel-1 and channel-2, maximum sample rate is 1 GSa/s and maximum memory is 1 M
points.