DATA SHEE T InfiniiVision 6000 X-Series Oscilloscopes
Table of Contents New Standard for Price Performance: Bandwidth, Visualization, and Integration ������������������������������������03 Configure your InfiniiVision 6000 X-Series Oscilloscope ���������������������������������������������������������������������������30 Performance Characteristics �����������������������������������������������������������������������������������������������������������������������32 Evolving Since 1939 �������������������������������������������������������������������������
New Standard for Price Performance: Bandwidth, Visualization, and Integration In the past, if you wanted an oscilloscope with exceptional performance, you could expect to pay a premium. Not anymore. The InfiniiVision 6000 X-Series oscilloscopes combine price and performance to set a new standard in the portable oscilloscope world. Imagine a 6 GHz bandwidth oscilloscope that sees and triggers on everything, helps you visualize complex waveforms and grows with your projects.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Overview of the Keysight InfiniiVision X-Series oscilloscopes InfiniiVision 6000 X-Series Analog channels 2 or 4 Digital channels (MSO) 16 4000 X-Series 2 or 4 16 3000T X-Series 2 or 4 16 2000 X-Series 2 or 4 8 Bandwidth (upgradable) Max sampling rate Max memory depth Max waveform update rate Display 200, 350, 500 MHz, 1, 1.5 GHz 5 GSa/s 4 Mpts > 1,000,000 waveforms/sec 12.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Bandwidth Superior signal integrity with total-cost- ofownership leadership 6 GHz, 20 GSa/s When you choose your next oscilloscope, bandwidth is the most important specification to consider, as it defines the maximum frequency content your oscilloscope can acquire. Acquiring signals with faster edge rates or faster fundamental frequencies requires higher-bandwidth scopes to make the most accurate measurements.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Bandwidth (Continued) 6 GHz Noise floor: 210 µVrms at 1 mV/div Accurate signal integrity measurements with an oscilloscope start with a low noise floor. With an innovative all-new front-end ASIC, the 6000 X-Series achieves a 210-μVrms noise floor at 1 mV/div for 6-GHz bandwidth or 115-μVrms noise floor at 1 mV/ div for 1-GHz bandwidth, helping you to make the most precise measurements.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Visualization The power of visualization: If you can’t see it, you can’t fix it Troubleshooting always starts with an acknowledgment of the problem, and a visual confirmation adds confidence in engineering troubleshooting. The feature-rich 6000 X-Series oscilloscopes include numerous visualization features offered for the first time in embedded-OS-class oscilloscopes. Use the 6000 X-Series’ 12.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Visualization (Continued) Visualize by ultimate isolation: The zone touch trigger Visualize by protocol isolation: Serial protocol trigger + the zone trigger One of the biggest challenges of using an oscilloscope is setting up an advanced trigger to isolate a signal of interest. While advanced triggers are powerful features, setting them up can slow you down. The zone touch trigger provides a turnkey trigger solution.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Visualization (Continued) Visualize distribution and intensity: Add depth to your analysis with color grade and histograms Color and graphical representations add depth to your signal analysis. With the standard color grade and histogram features, the 6000 X-Series oscilloscopes can quickly reveal just how often a particular event of interest occurs by providing a threedimensional quantitative view of the waveforms.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Visualization (Continued) Visualize signal integrity: Optional jitter analysis and real-time eye diagram analysis Jitter measurement has become a popular debugging technique. However, traditional jitter analysis options are often costly and focused on characterizations that may not be suited for real-time debugging. The 6000 X-Series DSOX6JITTER option focuses on real-time debugging for your everyday jitter analysis.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Visualization (Continued) Visualize signal integrity: Optional jitter analysis and real-time eye diagram analysis (Continued) The real-time eye diagram with clock recovery is another powerful and visual way to understand the signal integrity of your waveforms (requires Option DSOX6JITTER). It quickly provides information like eye width, eye height, and jitter and shows you any signal anomalies.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Visualization (Continued) Visualize burst events: Segmented memory — the smart and efficient way Acquisition memory size is an essential oscilloscope specification because it determines the amount of data you can capture in a single acquisition. In general, longer memory is better.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration Take advantage of a new oscilloscope application bundle that will enable ALL software applications (including serial decode and WaveGen) for one low price (Option DSOX6APPBNDL). More than just an oscilloscope, it’s 7 instruments in 1 Keysight Technologies, Inc. pioneered multiple-instrument integration with the release of the mixed signal oscilloscope (MSO) in 1996.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Integrate protocol analysis: Optional hardwarebased serial bus protocol decode and trigger Keysight Technologies, Inc. InfiniiVision X-Series scopes are the only oscilloscopes that use hardware-based serial protocol decoding. Other vendors’ oscilloscopes use software post-processing techniques to decode serial packets ⁄ frames.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Frequency Response Analysis (FRA) Option Frequency Response Analysis (FRA) is an often-critical measurement used to characterize the frequency response (gain and phase versus frequency) of a variety of today’s electronic designs, including passive filters, amplifier circuits, and negative feedback networks of switch mode power supplies (loop response).
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Integrate frequency measurements: Standard 10-digit counter and totalizer With the 6000 X-Series’ standard 10-digit counter, your expectations of an oscilloscope counter will be redefined. Traditional oscilloscope counter measurements offer only five or six digits of resolution.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Spectrum analysis and Multi-domain analysis: Enhanced color FFT function with peak search The enhanced color FFT takes your experience of oscilloscopebased spectrum analysis to the next level. –– Color grade immediately shows you the frequency and amplitude distributions of your signal. –– The frequency peak search eliminates tedious cursor measurements.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Talk to me: Multi-language voice control powered by Nuance Today’s devices operate with voice controls. Your smartphone and car navigation system respond to your voice commands. Why not your oscilloscopes? The 6000 X-Series oscilloscopes’ new voice control capability not only listens to you, but it understands you in your native language.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Optional mask/limit testing Whether you are performing pass/fail tests to specified standards in manufacturing or testing for infrequent signal anomalies, mask/limit testing (Option DSOX6MASK) can be a valuable productivity tool. The 6000 X-Series features powerful hardwarebased mask testing and can perform up to 130,000 tests per second.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Optional power measurements and analysis When you are working with switching power supplies and power devices, the power measurements application (Option DSOX6PWR) provides a full suite of power measurements and analysis in the oscilloscope.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Optional HDTV video triggering and analysis Whether you are debugging consumer electronics with HDTV or characterizing a design, the HDTV measurement application (Option DSOX6VID) provides support for a variety of HDTV standards for triggering and analysis.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Advanced math functions — display four simultaneously The 6000 X-Series provides the most advanced math analysis in an embedded-OS-based oscilloscope. You can nest together multiple math functions and display up to four math functions simultaneously. You also can apply color grade capability and histograms to a math function to gain further insights.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) 56 automatic measurements — display up to 10 simultaneously Automatic measurements are an essential tool for an oscilloscope. In order to make quick and efficient measurements, the 6000 X-Series provides 56 powerful automatic measurements and can display up to 10 at a time along with measurement statistics. Measurements can be gated by auto select, main window, zoom window, or cursors.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Connectivity and LXI compatibility Standard USB 2.0 hi-speed host ports (two on front, one on back) and device ports (one on back) make PC connectivity easy. Operate the oscilloscope from your PC and save/recall stored waveforms and setup files via standard LAN (LXI IPv6 Extended Function).
New Standard for Price Performance: Bandwidth, Visualization, and Integration Integration (Continued) Visual front panel The 6000 X-Series’ innovative capacitive touch screen is compatible with the latest tablet technologies. In addition to the traditional VNC-based virtual front panel remote operation through your favorite PC Web browser, the 6000 X-Series supports remote oscilloscope control from your tablet devices.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Powerful probe solutions and compatibility Get the most out of your 6000 X-Series oscilloscope by using Keysight’s complete family of innovative probes and accessories for your application. The 6000 X-Series supports up to four active probes simultaneously with its full AutoProbe interface 1. All 6000 X-Series oscilloscopes come standard with probes for each channel.
New Standard for Price Performance: Bandwidth, Visualization, and Integration Infiniium Offline oscilloscope analysis software Keysight’s Infiniium Offline PC-based oscilloscope analysis software (N8900A) allows you to do additional signal viewing, analysis, and documentation tasks away from your oscilloscope. Capture waveforms, save to a file, and recall the waveforms into InfiniiView.
New Standard for Price Performance: Bandwidth, Visualization, and Integration The portable oscilloscope class-leading 6 GHz upgradable bandwidth expands your application coverage including PCI Express. Designed for Touch. 12.1-inch capacitive multi-touch screen with gesture support sets a new visualization standard. Not a touch screen fan? You can turn off the touch screen. Zone touch trigger. If you can see it, you can trigger on it by drawing a zone box.
450,000 waveforms per second update rate minimizes the dead-time for maximum probability of capturing infrequent events and anomalies. Multi-language voice control enables hands-free operation while you are holding probes. Using docking panels with the capacitive touch screen adds a new dimension of usability. Move automatic measurements, cursors information, event lister, histogram, navigation, DVM, and the counter pane anywhere on the screen. Transparent panes are supported.
Configure your InfiniiVision 6000 X-Series Oscilloscope Step 1. Choose your number of channels InfiniiVision 6000 X-Series oscilloscopes Input channels DSOX6002A DSOX6004A MSOX6002A MSOX6004A 2 4 2 + 16 4 + 16 1 GHz Default 2.5 GHz DSOX6B10T252BW Step 2.
Configure your InfiniiVision 6000 X-Series Oscilloscope (Continued) Step 4. Choose your probes. For a complete list of compatible probes, see Keysight document 5968-8153EN Probes N2894A passive probe 700 MHz, 10:1, 9.5 pF, 10 MΩ N2756A 16 digital channel MSO cable N2870A passive probe 35 MHz, 1:1, 1 MΩ 10076B high-voltage passive probe (4 kV) N2796A active single-ended probe 2 GHz, 1 pF, 1 MΩ with AutoProbe N2797A active single-ended probe 1.
Performance Characteristics DSOX/MSO 6000 X-Series digital storage/mixed signal oscilloscopes 6000 X-Series specification overview Half channel bandwidth 1 (–3 dB) Full channel bandwidth 1 (–3 dB) Full channel equivalent time bandwidth 1 (–3 dB) Calculated rise time (10 to 90%) Input channels DSOX6002A DSOX6004A MSOX6002A MSOX6004A Maximum sample rate Maximum memory depth Display size and type Waveform update rate Typical noise floor at 1 mV/div, 50 Ω Vertical system analog channels Hardware bandwidth limit
Performance Characteristics (Continued) DSOX/MSO 6000 X-Series digital storage/mixed signal oscilloscopes (Continued) Vertical system digital channels Digital input channels Thresholds Threshold selections User-defined threshold range Maximum input voltage Threshold accuracy 1 Maximum input dynamic range Minimum voltage swing Input impedance Input capacitance Vertical resolution 16 digital (D0 to D15. Pod 1: D7 ~ D0, Pod 2: D15 ~ D8) Threshold per pod TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (–1.
Performance Characteristics (Continued) Acquisition system Maximum analog channels sample rate Analog channels equivalent sample rate Maximum analog ≤ 2 GSa/s channels record length > 2 GSa/s Maximum digital channels sample rate Maximum digital channels record length Acquisition mode Normal Peak detect Averaging High resolution Segmented Data acquisition mode Real time Max update rate Equivalent Time mode Normal Roll XY Trigger system Trigger sources Trigger modes Trigger coupling Normal Auto Single
Performance Characteristics (Continued) Trigger system Trigger jitter Trigger bandwidth Trigger sensitivity (internal) 1 Edge Other modes 1 GHz bandwidth 2.5, 4, and 6 GHz bandwidth Trigger sensitivity (external) 1 Trigger level range 1. ± 1.6 V ±8V Any channel External < 1.0-ps rms with the jitter-free trigger < 3.0-ps rms without the jitter-free trigger 500 MHz, 1 GHz, 2.5 GHz models: bandwidth of oscilloscope. 4-GHz and 6-GHz models: 3.
Performance Characteristics (Continued) Trigger type selections (Continued) Rise/fall time Nth edge burst Runt Setup and hold Video Enhanced video (HDTV) (Option) ARINC429 (Option) CAN (Option) FlexRay (Option) I²C (Option) I²S (Option) LIN (Option) MIL-STD1553 (Option) SPI (Option) UART/RS232/422/485 (Option) USB (Option) SENT (Option) User-definable Manchester/NRZ (Option) CXPI (Option) USB PD (Option) 1.
Performance Characteristics (Continued) Search, navigate, and lister Type Copy Frequency peak Source Max number of peaks Control Result display Waveform measurements DC vertical accuracy/cursors 2 Number of measurements Cursors Automatic measurements Snapshot Voltage/current Time Count Mixed Jitter Real-time eye Dual-channel (requires N2820A probe) Automatic measurement logging Counter Source Resolution Max frequency Edge, pulse width, rise/fall, runt, frequency peak, serial bus 1, serial bus 2 Copy to t
Performance Characteristics (Continued) Waveform math Number of math functions Arithmetic Enhanced FFT Record size Window types Display Waveforms Peak search Waveform analysis Mask/limit test (Option) Histogram Source Types Measurements Modes Color grade Source Color themes Modes Jitter (Option) Jitter measurement floor Source Clock recovery Real-time eye (Option) Source Clock recovery Color mode Measurements Precision mode Find us at www.keysight.com Four, displays all four simultaneously.
Performance Characteristics (Continued) Precision counter/totalizer (Specifications are typical) (option) Counter Source Any analog channel or trigger qualified event Resolution 10 digits (8 digits for trigger qualified event) Max frequency Up to 3.2 GHz (4 GHz typical). With Hi-speed USB 2.0 decoding, 1 GHz (1.
Performance Characteristics (Continued) Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (Continued) Sine Frequency range 0.1 Hz to 20 MHz Amplitude flatness ± 0.5 dB (relative to 1 kHz) Harmonic distortion –40 dBc Spurious (nonharmonics) –40 dBc Total harmonic distortion 1% SNR (50 Ω load, 500 MHz BW) 40 dB (Vpp ≥ 0.1 V); 30 dB (Vpp < 0.1V) Square wave/pulse Frequency range 0.
Performance Characteristics (Continued) Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (Continued) Amplitude Range: Minimum 20 mVpp if |offset| ≤ 0.5 Vpp into Hi-Z 1 10 mVpp if |offset| ≤ 0.5 Vpp into 50 Ω 1 Range: Maximum 10 Vpp except, 9 Vpp if sinc or cardiac, 7.5 Vpp if Gaussian pulse into Hi-Z; 5 Vpp/4.5 Vpp into 50 Ω Resolution 100 μV or 3 digits, whichever is higher Accuracy 1.
Performance Characteristics (Continued) Connectivity USB 2.0 hi-speed host port USB 2.0 hi-speed device port LAN port Web remote control Video-out port GPIB port 10-MHz reference Trigger out USB 2.0 hi-speed host ports x3, two front and one real panel. Supports memory devices, printers, keyboards, mice, and USB microphones One USB 2.0 hi-speed device port on rear panel. USB Test and Measurement Class (USBTMC) compatible 10/100/1000 Base-T port on rear panel.
Performance Characteristics (Continued) Non-volatile storage Reference waveform display Data/file save Setup/image Waveform data Application data Analysis results (*.csv) Max USB flash drive size Set ups without USB flash drive Set ups with USB flash drive Included standard with oscilloscope Calibration Probe Interface language support/built-in help Voice control support Power cord Front-panel protection Documentation Four internal waveforms or USB thumb drive.
| Keysight | InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. The business that became Keysight was a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.