Datasheet
03 | Keysight | N2780B Series AC/DC Current Probes A wide selection of current probes to meet your application’s needs - Data Sheet
Figure 3. Frequency response of N2783B
Figure 4. Continuous maximum input rating of N2783B
-10
-20
-30
-40
-50
100
10k
1M
100M
1
-60
Frequency (Hz)
Amplitude (dB)
35
30
25
20
15
10
5
10 100 1k 10k 100k 1M 10M 100M
Frequency (Hz)
Maximum input current (Arms)
Figure 5. Insertion impedance of N2783B
Figure 6. Amplitude accuracy characteristics of N2783B
100
1k 10k
100k
1M
10M
100M
Frequency (Hz)
1m
10m
100m
1
10
Input Impedance (ohm)
0.001 0.01 0.1 110 100
-6
-3
0
3
6
9
12
Input Current (A)
Deviation (%)
AC 50 Hz DC
N2779A 3-channel power supply specifications
Applicable current probes: N2780B, N2781B, N2782B, N2783B and N2774A
Number of power supply connectors: 3
Connector type: LEMO inc./FFA..0S.304.CNAC42Z
Output voltage: DC (12 V, 2.5 A)
Maximum rated power: 170 VA
Input power requirement: AC 100-240 VAC, 50/60 Hz, 125-170 VAC
Note: For the characteristic plots of other current probe models, refer to the N2780B Series current probe user’s manual.