Datasheet

15 | Keysight | InniiVision Oscilloscope Probes and Accessories - Data Sheet
Model number N2795A N2796A N2797A
Probe bandwidth* (–3 dB) 1 GHz 2 GHz 1.5 GHz
Risetime 350 ps 175 ps 233 psec
System bandwidth 500/600 MHz with
Keysight’s 500/600 MHz
InniiVision/Inniium,
1 GHz with 1 GHz
InniiVision 3000 X, 4000 X
1 GHz with Keysight’s
1 GHz InniiVision/Inniium, 1.5 GHz
with Keysight’s 1.5 GHz InniiVision
4000 X,
6000 X
Attenuation ratio (at dc) 10:1 ± 0.5%
Input dynamic range 8 to +8 V (DC or peak AC)
Non-destructive input voltage –20 to +20 V
Offset range ±8 V ±12 V
DC offset error (output zero) ±1 mV
Low frequency accuracy 0.5% at 70 Hz, 1 Vpp
Input resistance* 1 MΩ
Input capacitance 1 pF
Output impedance 50 Ω
Max number of probes
supported by InniiVision 3000
X-/5000/6000/7000 Series**
2
Max number of probes
supported by InniiVision
4000X, 6000X
4
* Denotes warranted electrical specications after 20 minute warm-up, all others are typical
** The N2797A is compatible with 3000 X-, 4000 X- and 6000 X-Series only.
N4839A Dual lead socketed adapter, 6 cm, qty 2
N4840A Dual lead solder-in adapter, 5 cm, qty 2
N4841A Dual lead socketed adapter, 9 cm, qty 2
N4842A Dual pin PCB header, qty 2
N4843A Solderable tips, qty 10
N4844A Right angle ground lead, 5 cm, qty 2
N4845A Ground blade, qty 2
N4846A Offset ground, qty 2
Single-ended Active
Probes
N2795A/96A/97A low-cost
single-ended active voltage
High resistance (1MΩ) and low
capacitance (1 pF) input for low
loading
Wide input dynamic range (±8 V) and
offset range (±12 V for N2796A/97A,
±8 V for N2795A)
Built-in headlight
Direct connection to AutoProbe
interface (no power supply required)
N2797A for extreme temperature
environmental chamber testing at –40
to +85 °C
The N2795A/96A are a new generation of
low-cost, 1 to 2 GHz single-ended active
probes with the AutoProbe interface
(compatible with Keysight’s InniVision
and Inniium family of oscilloscopes).
These probes integrate many of the
characteristics needed for today’s
general-purpose, high-speed
probing–especially in digital system
design, component design/
characterization, and educational research
applications. Its 1 MΩ input resistance and
extremely low input capacitance (1 pF)
provide ultra low loading of the DUT. This,
accompanied with superior signal delity,
makes these probes useful for most of
today’s digital logic voltages. Testing
devices over extreme temperature ranges
is quite common these days. The N2797A
1.5 GHz single-ended active probe is the
industry’s rst low-cost high input
impedance active probe with rugged
probe tips for environmental chamber
testing of ICs and devices. It gives the
ability to probe signals at drastic
temperature swings ranging from –40 to
+85 °C. The probe provides a 2 m long
cable. Order N2798A for re-ordering
accessories.
The N2795A/96A/97A are equipped with
a white LED headlight to illuminate the
circuit under test. The probes are powered
directly by the InniiVision and Inniium
Autoprobe interface, eliminating the need
for an additional power supply. The probes
also come with a number of accessories
that allow for easy connections to the
circuit under test.
For more information about N2795A/96A/97A active probe, refer to the Keysight
N2795A/96A/97A active probe data sheet, literature number 5990-6480EN.
Replacement accessories