Datasheet

03 | Keysight | InniiVision Oscilloscope Probes and Accessories - Data Sheet
Probe Compatibility Table
For ordering information when replacing your probe or probe accessory: Refer directly to the page number listed in the table of
contents for your probe model.
To assist you in selecting the proper probe for your application: Use our probe compatibility table below to nd the probes that are
recommended for use with your 2000 X-, 3000 X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series InniiVision oscilloscope.
Probe type Probe model MSO/DSO
2000 X
1
MSO/DSO
3000 X
MSO/DSO
4000 X/6000 X
2
Passive probes,
page 4
N2862B 10:1 150 MHz
(included in 70/100 MHz models)
N2863B 10:1 300 MHz
(included in 200 MHz models)
N2890A 10:1 500 MHz
(included in 350/500 MHz/1 GHz models)
Recommended Recommended Recommended
N2894A 10:1 700 MHz (included in 4000 X models) Compatible Compatible Compatible
N2889A 1:1/10:1 350 MHz Recommended Recommended Recommended
High-voltage passive
probes, page 7
10076C 4 kV Recommended Recommended Recommended
N2771B 30 kV Recommended Recommended Recommended
1130A - 1134A 1.5 GHz - 7 GHz Incompatible Recommended Recommended
Differential active probes,
page 8
N2750A - N2752A 1.5 GHz - 6 GHz Incompatible Recommended Recommended
1141A 200 MHz (use with 1142A) Incompatible Recommended Recommended
N2791A 25 MHz Recommended Recommended Recommended
N2891A 70 MHz Recommended Recommended Recommended
N2790A 100 MHz (with AutoProbe) Incompatible Recommended Recommended
N2792A 200 MHz Incompatible Recommended Recommended
N2818A 200 MHz (with AutoProbe) Incompatible Recommended Recommended
N2793A 800 MHz Incompatible Recommended Recommended
N2819A 800 MHz (with AutoProbe) Incompatible Recommended Recommended
N2804A 300 MHz Incompatible Recommended Recommended
3
N2805A 200 MHz Incompatible Recommended Recommended
3
Single-ended active probes,
page 15
N2795A 1 GHz (with AutoProbe) Incompatible Recommended Recommended
N2796A 2 GHz (with AutoProbe) Incompatible Recommended Recommended
N2797A 1.5 GHz (with AutoProbe) Incompatible Recommended Recommended
N7020A 2 GHz Incompatible Incompatible Recommended
3
MSO logic probes,
page 17
01650-61607 16-channel Incompatible Recommended Recommended
N6459-60001 8-channel MSO cable
(included in 2000 X-Series MSOs)
Recommended Incompatible Incompatible
N6450-60001 16-channel MSO cable
(included in 3000 and 4000 X-Series MSOs)
Incompatible Recommended Recommended
N2756A 16-Channel MSO cable
(included in 6000 X-Series MSOs)
Incompatible Recommended Recommended
Current probes,
page 19
1146B 100 kHz Recommended Recommended Recommended
N2780B 2 MHz (use with N2779A) Recommended Recommended Recommended
N2781B 10 MHz (use with N2779A) Recommended Recommended Recommended
N2782B 50 MHz (use with N2779A) Recommended Recommended Recommended
N2783B 100 MHz (use with N2779A) Recommended Recommended Recommended
1147B 50 MHz (with AutoProbe) Incompatible Recommended Recommended
N2893A 100 MHz (with AutoProbe) Incompatible Recommended Recommended
N2820A 3 MHz/50 uA High Sensitivity,
2 channel (with AutoProbe)
Incompatible Recommended Recommended
N2821A 3 MHz/50 uA High Sensitivity,
1 channel (with AutoProbe)
Incompatible Recommended Recommended
1. The 2000 X-Series does not support AutoProbe interface active probes.
2. The 4000 X- and 6000 X-Series comes with the Inniium AutoProbe interface for higher probe power support.
3. Recommended with 4000 X-Series only.