Datasheet

04 | Keysight | N3300 Series DC Electronic Loads - Data Sheet
Specifications
Table A-1 lists the specifications for the different load models. Specifications indicate warranted performance in the 25 °C ± 5 °C region
of the operating temperature range. Specifications apply to normal and transient modes unless otherwise noted.
N3302A N3303A N3304A N3304-J01
Special order option
N3305A N3306A N3307A
Input ratings
Current 0–30 A 0–10 A 0–60 A 0–60 A 0–60 A 0–120 A 0–30 A
Voltage 0–60 V 0–240 V 0–60 V 0–80 V 0–150 V 0–60 V 0–150 V
Maximum power @ 40 °C1 150 W 250 W 300 W 300 W 500 W 600 W 250 W
Input characteristic
Operating contour
Derated current detail
N3302A N3303A N3304A N3304-J01
Special order option
N3305A N3306A N3307A
Specified current @ low voltage operation
2.0 V 30 A 10 A 60 A 60 A 60 A 120 A 30 A
1.5 V 22.5 A 7.5 A 45 A 45 A 45 A 90 A 22.5 A
1.0 V 15 A 5 A 30 A 30 A 30 A 60 A 15 A
0.5 V 7.5 A 2.5 A 15 A 15 A 15 A 30 A 7.5 A
0 V
0 A 0 A 0 A 0 A 0 A 0 A 0 A
1. Maximum continuous power available is derated linearly from 100% of maximum at 40 °C, to 75% of maximum at 55 °C.
Table A-1 states that maximum current is available down to 2 volts. Typically, however
under normal operating conditions, the load can sink the maximum
current down to the following voltages:
N3302A N3303A N3304A
N3304-J01
Special order option
N3305A N3306A N3307A
Typical minimum operating voltage @ full scale current
1.2 V 1.2 V 1.2 V 1.2 V 1.4 V 1.4 V 1.4 V
Table A-1