Datasheet

07 | Keysight | N3300 Series DC Electronic Loads - Data Sheet
Supplemental Characteristics
Table A-2 (continued)
N3302A N3303A N3304A/
N3304A-J01
N3305A N3306A N3307A
Ripple and noise (20 Hz–10 MHz)
Current (rms/peak to peak) 2 mA/
20 mA
1 mA/
10 mA
4 mA/
40 mA
4 mA/
40 mA
6 mA/
60 mA
2 mA/
20 mA
Voltage (rms) 5 mV rms 12 mV rms 6 mV rms2 10 mV rms 8 mV rms 10 mV rms
External analog programming
Voltage programming accuracy
1
0.5% + 12 mV 48 mV 12 mV 30 mV 12 mV 30 mV
Current programming accuracy
1
0.25% + 4.5 mA 1.5 mA 9 mA 9 mA 18 mA 4.5 mA
External monitor ports
Voltage monitor accuracy 0.25% + 12 mV 48 mV 12 mV 30 mV 12 mV 30 mV
Current monitor accuracy 0.1% + 4.5 mA 1.5 mA 9 mA 9 mA 18 mA 4.5 mA
1. Applies to all ranges.
2. Ripple and noise for N3304-J01 = 8 mV rms.
Table A-3
N3300A N3301A
Operating temperature range
0 °C to 55 °C 0 °C to 55 °C
Input ratings
Operating range
100–250 VAC; 48–63 Hz 100–250 VAC; 48–63 Hz
Input current
4.2 A @ 100127 VAC;
2.2 A @ 200–250 VAC
2.3 A @ 100–250 VAC
Input VA
440 VA 230 VA
Inrush current 38 A 18 A @ 115 VAC; 36 A @ 230 VAC
Number of samples or points Measurement time Additional fixed offset (in addition to measurement accuracy
1000 samples (default) 20 ms none
200 samples 10 ms < 6%
100 samples 9 ms < 10%
20 points 7 ms < 30%
< 20 points 7 ms > 30%
Table A-3 lists the supplemental characteristics for the different mainframes
Table A-4 Measurement time