DATA SHEE T U8000 Series Single Output DC Power Supplies
Key Features • Excellent load and line regulation: (CV: <0.01% +2 mV; CC: <0.02% + 2mA) • Low output noise: 1 mVrms (20 Hz to 20 MHz) • Over Voltage and Over Current Protection • LCD display with backlight capability Figure 1.
Work Efficiently with Great Features and Solid Performance — Within Budget Differentiated features typically found only in programmable power supplies The U8000 Series offers fully integrated over voltage protection (OVP) and over current protection (OCP) to prevent damage to the device-under-test (DUT). Using the capability to save and recall three memory states, you can minimize errors and reduce set-up time.
Features of the U8000 Series integrated over voltage • Fully and over current protection to prevent damages to the DUT Three storage locations (M1, M2, and M3) for user-defined operating states • with save-and-recall capability Highly visible LCD displaying actual values of output voltage and current in meter mode and limit values of voltage and current in limit mode Backlight On/Off options enabling brighter data display and display of the voltage •Setting and current limit values knob for quick • Rot
Performance Specifications Electrical Specifications Parameter Output Ratings (at 0 °C to 40 °C) U8001A U8002A 0 to +30 V 0 to 3 A Line and Load Regulation Ripple and Noise (25 °C ±5 °C) Load Transient Response Time (within 15 mV from full load to half load and from half load to full load) Programming Accuracy1 (25 °C ±5 °C) Readback Accuracy1 (25 °C ±5 ° C) Meter Resolution Maximum Output Float Voltage 1 0 to +30 V 0 to 5 A CV: <0.01% +2 mV CC: <0.
Supplemental Characteristics Supplemental Characteristics Parameter Temperature Coefficient (for 12 months) Output Voltage Overshoot (during turn-on or turn-off of AC power state with the output control set to less than 1 V) Voltage Programming Speed, to within 1% of total excursion Up Full Load No Load Down Full Load No Load Last Memory Setting Enabled Over Voltage Protection Response Time Protection Features Parameter Over Voltage Protection Accuracy ± (% of output + offset) Over Voltage Protection Progr
General Characteristics Display • Liquid Crystal Display (LCD) Operating Environment • Operating temperature from 0 °C to 40 °C (for full rated output) and 40 °C to 55 °C (for derated output) Ordering Information • U8001A DC Power Supply, 30 V, 3 A • U8002A DC Power Supply, 30 V, 5 A Rack-mount Kits • Altitude up to 2000 meters • package Safety and EMC Compliance Certified with: • IEC 61326:2002/ EN61326:1997+ A1:1998+A3:2003 • CISPR 11:1990/ EN55011:1990 • Canada: ICES-001:2004 • Australia/New Zealand
Learn more at: www.keysight.com For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Find us at www.keysight.com This information is subject to change without notice.