LINE VOLT
(V)
POWER
FACTOR
LINE CURRENT
INPUT
POWER (W)
OPEN CIRCUIT
VOLTAGE (V)
MINIMUM
START TEMP
UL TEMP
CODE
WIRING
DIAGRAM
OPERATING OPEN START
120 High 1.20 2.32 1.30 125 280 -40ºC A H5
208 High 0.67 1.39 0.90 132 290 -40ºC A H5
240 High 0.58 1.16 0.60 125 280 -40ºC A H5
277 High 0.50 1.00 0.48 125 280 -40ºC A H5
• ANSI Designation: M90
• Line Voltage: 120/208/240/277
• Regulation: 5%
• Frequency: 60 Hz
• Recommended Fuse (A): 5/4/3/3
• Circuit Type: HX-HPF
• Insulation Class: 180ºC
• Capacitor Value: 12 MF
• Capacitor Voltage Rating: 280 V
• Capacitor Temperature Rating: 90ºC
• Winding Materials: Cu/Cu
• Lamp Starter: XG-04
• Agency Certification: RU, cRU
• Maximum Distance to Lamp: 10 FT
• 2 Year Warranty
LAMP TYPE: 100W MH INPUT VOLTAGE: Quad (120/208/240/277) CIRCUIT TYPE: HX-HPF
MH-100X-Q-KIT
100W Meta l h a l i d e
PRODUCT FEATURES
ELECTRICAL SPECIFICATIONS
WIRING DIAGRAMS
Specifications subject to change. Revised 11/29/11
Keystone Technologies, LLC P.O. Box 246, Ambler PA 19002 Phone (800) 464-2680 Fax (215) 628-4412 www.keystoneballast.com
DIAGRAM H5
COM
COM
LINE
X2
X3
C1
OPTIONAL
TO LINE
LAMP
X1
277V
CAP
240V
208V
120V
IGNITOR