Installation Guide

SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
This xture is intended for installation in accordance with the National
Electric Code (NEC) and Local code specications. Failure to adhere to
these codes and instructions may result in serious injury and/or property
damage and will void the warranty.
1) WARNING: This xture is not to be installed within 10 feet (3M) of a pool,
spa or fountain.
2) This xture is to be used only with a power unit (transformer) rated a maximum
of 300 W (25 AMPS) 15 volts.
3) According to the requirements of the National Electric Code (NEC), direct
burial rated wire is to be buried a minimum of 6” [152mm] beneath the
surface of the ground.
NOTE: If additional Direct Burial wire is needed, contact your local
Kichler
®
landscape distributor.
8 GA wire can be purchased in length of 250’ (76 M), 15503-BK.
10 GA wire can be purchased in length of 250’ (76 M), 15504-BK.
12 GA wire can be purchased in lengths of 100’ (30 M), 15501-BK; 250’
(76 M), 15502-BK; 500’ (152M), 15505-BK; and 1000’ (304 M), 15506-BK.
4) Fixture shall not use a tungsten halogen lamp unless the xture is marked
for use with such lamps.
5) Wiring connections must be made with approved/listed wire connection
device(s) suitable for the application. Do not exceed manufacturers’ wiring
combination specications for size and quantity of conductors.
CAUTION
WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW VOLTAGE),
CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALLY COMBUSTIBLE MATERIALS.
WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE NEEDLES,
GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT HAS ACCUMULATED ON THE LIGHT
BULB, LENS, OR BODY OF THE FIXTURE.
1) Well xture can be installed two different ways.
A) If xture is to be used for direct uplighting, dig hole in soil 15” deep.
B) If xture is to be used for wall washing, dig hole in soil 9-1/2” deep. These
dimensions will make hole large enough to accommodate sleeve plus 6”
of pea gravel. To insure proper drainage, ll bottom of hole with 6” of
pea gravel.
2) For direct uplighting set sleeve in deep hole with angled end down. For
wall washing set sleeve in shallow hole with angled end up.
3) Assemble rubber clips to yoke with groove at top facing center.
NOTE: One clip should always be assembled at back of yoke (where hook
is) then equally space the remaining two.
4) Connect wires to contacts on back of bulb and snap bulb into rubber clips.
5) Guide wire through bottom of sleeve and up along the outside of sleeve.
Set yoke into sleeve adjusting as needed.
(NOTE: Hook on yoke has a short side and a long side, use short side with
yoke at across the top for uplighting. Use long side with yoke angled for
wall washing purposes.
6) Fill gaps surrounding sleeve with soil.
7) Make wire connection to main low voltage supply wire.
Date Issued: 12/2/11 IS-15088-US
For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page
Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page
QUIC DISC
WIRING INSTRUCTIONS
Turn off power.
The full length of the 18 GA xture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are met:
Wiring is to be protected by routing close to the xture or accessory or secured to a building structure such as house or deck.
18 GA xture wiring is to be cut off so that it is attached to the connector within 6 inches of the xture or building structure.
If it is necessary to make the connections underground, then no more than 6 inches of the 18 GA xture wire is to be buried.
The Quic Disc
connector is designed to install one xture and accommodates one 18 GA xture wire and one 10 GA or one 12 GA supply wire.
Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc
or place the 12 gauge supply wire across the area marked 12 GA
on Quic Disc
.
Place the 18 gauge xture wire across the area marked 18 GA on the Quic Disc
. After the wires are in place, connecta the top of the Quic
Disc
to the base with supplied screw, making sure that the wires remain at in the bottom portion of the Quic Disc
, and the screw is tightened
all the way down.
The copper contacts will automatically pierce the wires’ insulation. Excess 18 GA xture wire that sticks out the end of the Quic Disc
is to be cut off.
Make no other wiring connections to the 18 GA xture wire.
GROOVE
GARGANTA
BULB
BOMBILLA
RUBBER CLIP
ABRAZADERA
YOKE
HORQUILLA
UP-LIGHTING SLEEVE
CAMISA DE
ILUMINACION
HACIA ARRIBA
WALL-WASH SLEEVE
CAMISA DE ILUMINACION

Summary of content (2 pages)