User Manual

• This device is accepted as a component of a landscape lighting
system where the suitability of the combination shall be determined by
CSA or local authorities having jurisdiction. To comply with CSA
requirement, this xture should be installed by a qualied electrician.
WARNING: Risk of electric shock, use only with low voltage landscape
xtures and accessories. Not suitable for use with submersible (fountain)
lighting xtures. DO not use with swimming pool or spa lighting xtures.
Do not connect two or more power supplies in parallel.
For use with fountains covered by Article 680 Part E of the National
Electrical Code, NFPA 70.
For outdoor use only.
National Electrical Code requires that wiring where concealed or
extended through a building wall must be enclosed in conduit.
This outdoor power unit shall be connected to a 115/120 volt covered
GFCI receptacle marked “Wet Location” while in use.
The 8, 10, 12 or 16GA cable is intended for shallow burial. Bury cable
a minimum of 6 inches (152 mm) below the surface. NOTE: If more
cable is needed, contact your local Kichler® Landscape distributor.
Finding Transformer Load: Low voltage systems require the use of a
transformer to reduce standard 120-VOLT power from your home
to12-VOLTS. To determine the transformer size you will need, add up
the wattages of all lamps you plan to use. Select a transformer that
matches as closely as possible to the total lamp wattage. For example,
if you have 11 xtures all rated at 24.4 watts, you will need a 300 watt
(VA) transformer (11 x 24.4 = 268.4 watts). Generally, the total lamp
load should not be less than one-third the transformers wattage rating,
nor exceed its maximum wattage capacity. If your total wattage is too
high, either divide the load between two transformers, or use a more
powerful transformer.
SAFETY INSTRUCTIONS
Este dispositivo es aceptado como un componente del sistema de
alumbrado panorámico donde la compatibilidad de la combinación se
determinará por CSA o las autoridades locales que tengan jurisdicción.
Para cumplir con los requisitos de CSA, este artefacto se debe instalar
por un electricista calicado.
ADVERTENCIA: Riesgo de choque eléctrico, use solamente con los
accesorios y artefactos de alumbrado panorámico de baja tensión. No
es adecuado para usar con los artefactos de alumbrado sumergibles
(fuente). NO utilice con los artefactos para piscinas (o albercas) o con
manantiales de agua mineral (spa).
No conecte dos o más alimentaciones eléctricas en paralelo.
Para uso con las fuentes que cubren el Artículo 680, Parte E del
Código Eléctrico Nacional, NFPA 70.
Solamente para uso al aire libre.
• El Código Eléctrico Nacional exige que el cableado, donde esté escondido
o extendido a través de la pared de un edicio, debe estar encerrado
en un conducto.
Esta unidad de potencia al aire libre se debe conectar a un receptáculo
de interruptor accionado por corriente de pérdida a tierra, cubierto, de
115/120 voltios, marcado “lugar húmedo”, mientras se use.
Los cables de calibre 8, 10, 12 ó 16 están destinados para enterrarlos
a poca profundidad. Soterre el cable un mínimo de 6 pulgadas
(152 mm.) debajo de la supercie. NOTA: Si se necesita más cable,
comuníquese con el distribuidor local de Kichler
®
Landscape.
• Encontrar la carga del transformador: Los sistemas de baja tensión
necesitan que se use un transformador para reducir a 12 VOLTIOS la
corriente de 120 VOLTIOS estándar de su casa. Para determinar el
tamaño del transformador usted necesita sumar el vataje de todas las
lámparas que piensa utilizar. Escoja un transformador que corresponda
tan cerca como sea posible al vataje total de las lámparas. Por ejemplo:
Si usted tiene 11 artefactos, todos de 24.4 vatios, usted necesita un
transformador de 300 vatios (VA) (11 x 24.4 = 268.4 vatios). Generalmente,
la carga total de lámpara no debe ser menor de un tercio del régimen
nominal de vataje de los transformadores, ni debe exceder laxima
capacidad de vataje. Si su vataje total es demasiado alto, o divida la
carga entre dos transformadores o use un transformador más potente.
INSTRUCCIONES DE SEGURIDAD
Date Issued: 1/27/12 IS-15402-US
SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
This xture is intended for installation in accordance with the National Electric Code (NEC) and Local code specications. Failure to adhere to
these codes and instructions may result in serious injury and/or property damage and will void the warranty.
1) WARNING: This xture is not to be installed within 10 feet (3M) of a pool, spa or fountain.
2) This xture is to be used only with a power unit (transformer) rated a maximum of 300 W (25 AMPS) 15 volts.
3) The #18 ga. xture wire is not intended for direct burial.
4) Direct burial rated wire is to be buried a minimum of 6” (152mm) beneath the surface of the ground.
NOTE: If additional Direct Burial wire is needed, contact your local Kichler
®
landscape distributor.
8 GA wire can be purchased in length of 250’ (76 M), 15503-BK.
• 10 GA wire can be purchased in length of 250’ (76 M), 15504-BK.
• 12 GA wire can be purchased in lengths of 100’ (30 M), 15501-BK; 250’ (76 M), 15502-BK; 500’ (152M), 15505-BK; and 1000’ (304 M), 15506-BK.
5) Fixture shall not use a tungsten halogen lamp unless the xture is marked for use with such lamps.
6) Wiring connections must be made with approved/listed wire connection device(s) suitable for the application. Do not exceed manufacturers’ wiring
combination specications for size and quantity of conductors.
INSTRUCCIONES DE SEGURIDAD
Primero lea esto
Guarde estas instrucciones
Este artefacto se debe instalar de acuerdo con el Código Eléctrico Nacional (NEC, por sus siglas en inglés) y con las especicaciones del código
local. No cumplir con estos códigos e instrucciones puede resultar en lesiones graves y/ o en daños a la propiedad y anulará la garantía.
1) ADVERTENCIAERTENCIA: Este artefacto no debe instalarse a menos de 10 pies (3 m) de una piscina (alberca), spa o fuente.
2) Este artefacto debe utilizarse solamente con una unidad de potencia (tranformador) con capacidad nominal máxima de 300 vatios (25 amp.) 15 voltios.
3) El alambre del artefacto calibre No. 18 no es para soterrado directo.
4) El alambre clasicado para soterrado directo se debe enterrar un mínimo de 6 pulgadas (152 mm) debajo de la supercie del terreno.
NOTA: Si necesita alambre de soterrado directo adicional, comuníquese con su distribuidor local Kichler® de productos de jardinería ornamental.
El alambre calibre 8 puede comprarse en longitud de 250’ (76 m.), 15503-BK
El alambre calibre 10 puede comprarse en longitud de 250’ (76 m.), 15504-BK
El alambre calibre 12 puede comprarse en longitudes de 75’ (22 m.), 15550-BK; 100’ (30 m.), 15501-BK; 250’ (76 m.), 15502-BK; 500’ (152 m.),
15505-BK; y 1000’ (304 m.), 15506-BK.
5) El artefacto no debe utilizarse con lámparas de halógeno, a menoss que el artefacto esté marcado para usar con tales lámparas.
6) Las conexiones de cableado se deben hacer con las conexiones del(los) dispositivos) de conexión de cableado aprobados/ de la lista, adecuados
para la aplicación. No exceda las especicaciones de combinación de cableado del fabricante para el tamaño y cantidad de conductores.