Installation Guide

Date Issued: 1/27/12 IS-15409-US
• Thisdeviceisacceptedasacomponentofalandscapelightingsystem
wherethesuitabilityofthecombinationshallbedeterminedbyCSAor
localauthoritieshavingjurisdiction.TocomplywithCSArequirement,
thisxtureshouldbeinstalledbyaqualiedelectrician.
• WARNING:Riskofelectricshock,useonlywithlowvoltagelandscape
xturesandaccessories.Notsuitableforusewithsubmersible(fountain)
lightingxtures.DOnotusewithswimmingpoolorspalightingxtures.
• Donotconnecttwoormorepowersuppliesinparallel.
• ForusewithfountainscoveredbyArticle680PartEoftheNational
ElectricalCode,NFPA70.
• Foroutdooruseonly.
• NationalElectricalCoderequiresthatwiringwhereconcealedor
extendedthroughabuildingwallmustbeenclosedinconduit.
•Thisoutdoorpowerunitshallbeconnectedtoa115/120voltcovered
GFCIreceptaclemarked“WetLocation”whileinuse.
• The8,10,12or16GAcableisintendedforshallowburial.Burycable
aminimumof6inches(152mm)belowthesurface.NOTE:Ifmore
cableisneeded,contactyourlocalKichler®Landscapedistributor.
• FindingTransformerLoad:Lowvoltagesystemsrequiretheuseofa
transformertoreducestandard120-VOLTpowerfromyourhome
to12-VOLTS.Todeterminethetransformersizeyouwillneed,addup
thewattagesofalllampsyouplantouse.Selectatransformerthat
matchesascloselyaspossibletothetotallampwattage.Forexample,
ifyouhave11xturesallratedat24.4watts,youwillneeda300watt
(VA)transformer(11x24.4=268.4watts).Generally,thetotallamp
loadshouldnotbelessthanone-thirdthetransformerswattagerating,
norexceeditsmaximumwattagecapacity.Ifyourtotalwattageistoo
high,eitherdividetheloadbetweentwotransformers,oruseamore
powerfultransformer.
SAFETY INSTRUCTIONS
• Estedispositivoesaceptadocomouncomponentedelsistemade
alumbradopanorámicodondelacompatibilidaddelacombinaciónse
determinaráporCSAolasautoridadeslocalesquetenganjurisdicción.
ParacumplirconlosrequisitosdeCSA,esteartefactosedebeinstalar
porunelectricistacalicado.
• ADVERTENCIA:Riesgodechoqueeléctrico,usesolamenteconlos
accesoriosyartefactosdealumbradopanorámicodebajatensión.No
esadecuadoparausarconlosartefactosdealumbradosumergibles
(fuente).NOutiliceconlosartefactosparapiscinas(oalbercas)ocon
manantialesdeaguamineral(spa).
• Noconectedosomásalimentacioneseléctricasenparalelo.
• ParausoconlasfuentesquecubrenelArtículo680,ParteEdel
CódigoEléctricoNacional,NFPA70.
• Solamenteparausoalairelibre.
• ElCódigoEléctricoNacionalexigequeelcableado,dondeestéescondido
oextendidoatravésdelapareddeunedicio,debeestarencerrado
enunconducto.
• Estaunidaddepotenciaalairelibresedebeconectaraunreceptáculo
deinterruptoraccionadoporcorrientedepérdidaatierra,cubierto,de
115/120voltios,marcado“lugarhúmedo”,mientrasseuse.
• Loscablesdecalibre8,10,12ó16estándestinadosparaenterrarlos
apocaprofundidad.Soterreelcableunmínimode6pulgadas
(152mm.)debajodelasupercie.NOTA:Sisenecesitamáscable,
comuníqueseconeldistribuidorlocaldeKichler
®
Landscape.
•Encontrarlacargadeltransformador:Lossistemasdebajatensión
necesitanqueseuseuntransformadorparareducira12VOLTIOSla
corrientede120VOLTIOSestándardesucasa.Paradeterminarel
tamañodeltransformadorustednecesitasumarelvatajedetodaslas
lámparasquepiensautilizar.Escojauntransformadorquecorresponda
tancercacomoseaposiblealvatajetotaldelaslámparas.Porejemplo:
Siustedtiene11artefactos,todosde24.4vatios,ustednecesitaun
transformadorde300vatios(VA)(11x24.4=268.4vatios).Generalmente,
lacargatotaldelámparanodebesermenordeunterciodelrégimen
nominaldevatajedelostransformadores,nidebeexcederlamáxima
capacidaddevataje.Sisuvatajetotalesdemasiadoalto,odividala
cargaentredostransformadoresouseuntransformadormáspotente.
INSTRUCCIONES DE SEGURIDAD
SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
This xture is intended for installation in accordance with the National Electric Code (NEC) and Local code specications. Failure to adhere to
these codes and instructions may result in serious injury and/or property damage and will void the warranty.
1) WARNING: Thisxtureisnottobeinstalledwithin10feet(3M)ofapool,spaorfountain.
2) Thisxtureistobeusedonlywithapowerunit(transformer)ratedamaximumof300W(25AMPS)15volts.
3) The#18ga.xturewireisnotintendedfordirectburial.
4) Directburialratedwireistobeburiedaminimumof6”(152mm)beneaththesurfaceoftheground.
NOTE:IfadditionalDirectBurialwireisneeded,contactyourlocalKichler
®
landscapedistributor.
•8GAwirecanbepurchasedinlengthof250’(76M),15503-BK.
•10GAwirecanbepurchasedinlengthof250’(76M),15504-BK.
•12GAwirecanbepurchasedinlengthsof100’(30M),15501-BK;250’(76M),15502-BK;500’(152M),15505-BK;and1000’(304M),15506-BK.
5) Fixtureshallnotuseatungstenhalogenlampunlessthextureismarkedforusewithsuchlamps.
6) Wiringconnectionsmustbemadewithapproved/listedwireconnectiondevice(s)suitablefortheapplication.Donotexceedmanufacturers’wiring
combinationspecicationsforsizeandquantityofconductors.
INSTRUCCIONES DE SEGURIDAD
Primero lea esto
Guarde estas instrucciones
Este artefacto se debe instalar de acuerdo con el Código Eléctrico Nacional (NEC, por sus siglas en inglés) y con las especicaciones del
código local. No cumplir con estos códigos e instrucciones puede resultar en lesiones graves y/ o en daños a la propiedad y anulará la
garantía.
1) ADVERTENCIAERTENCIA:Esteartefactonodebeinstalarseamenosde10pies(3m)deunapiscina(alberca),spaofuente.
2) Esteartefactodebeutilizarsesolamenteconunaunidaddepotencia(tranformador)concapacidadnominalmáximade300vatios(25amp.)15voltios.
3) ElalambredelartefactocalibreNo.18noesparasoterradodirecto.
4) Elalambreclasicadoparasoterradodirectosedebeenterrarunmínimode6pulgadas(152mm)debajodelasuperciedelterreno.
NOTA:Sinecesitaalambredesoterradodirectoadicional,comuníqueseconsudistribuidorlocalKichler®deproductosdejardineríaornamental.
•Elalambrecalibre8puedecomprarseenlongitudde250’(76m.),15503-BK
•Elalambrecalibre10puedecomprarseenlongitudde250’(76m.),15504-BK
•Elalambrecalibre12puedecomprarseenlongitudesde75’(22m.),15550-BK;100’(30m.),15501-BK;250’(76m.),15502-BK;500’(152m.),
15505-BK;y1000’(304m.),15506-BK.
5) Elartefactonodebeutilizarseconlámparasdehalógeno,amenossqueelartefactoestémarcadoparausarcontaleslámparas.
6) Lasconexionesdecableadosedebenhacerconlasconexionesdel(los)dispositivos)deconexióndecableadoaprobados/delalista,adecuados
paralaaplicación.Noexcedalasespecicacionesdecombinacióndecableadodelfabricanteparaeltamañoycantidaddeconductores.

Summary of content (2 pages)