Installation Manual

INSTALLATION INSTRUCTIONS
Model 15810R (CP300373)
SAFETY INSTRUCTIONS
READ THESE INSTRUCTIONS FIRST.
SAVE FOR FUTURE REFERENCE.
This fixture is intended for installation in accordance with the
National Electric Code (NEC) and Local code specifications.
Failure to adhere to these codes and instructions may result in
serious injury and/or property damage and will void the war-
ranty.
1) WARNING: This fixture is not to be installed within 10 feet (3M)
of a pool, spa or fountain.
2) This fixture is to be used only with a power unit (transformer)
rated a maximum of 300 W (25 AMPS) 15 volts.
3) The #18 ga. fixture wire is not intended for direct burial.
4) Direct burial rated wire is to be buried a minimum of 6”
(152mm) beneath the surface of the ground.
NOTE: If additional Direct Burial wire is needed, contact your
local Kichler
®
landscape distributor.
8GAwirecanbepurchasedinlengthof250’(76M),15503-BK.
•10GAwirecanbepurchasedinlengthof250’(76M),
15504-BK.
•12GAwirecanbepurchasedinlengthsof100’(30M),
15501-BK;250’(76M),15502-BK;500’(152M),15505-BK;and
1000’(304M),15506-BK.
5) Fixture shall not use a tungsten halogen lamp unless the fixture
is marked for use with such lamps.
6) Wiring connections must be made with approved/listed wire
connection device(s) suitable for the application. Do not exceed
manufacturers’wiringcombinationspecicationsforsizeand
quantity of conductors.
CAUTION
WHEN INSTALLING KICHLER LANDSCAPE LIGHTING (LINE VOLTAGE OR LOW
VOLTAGE), CARE SHOULD BE TAKEN TO KEEP CLEAR OF POTENTIALLY COM-
BUSTIBLE MATERIALS.
WHEN MAINTAINING THE FIXTURES, BE SURE TO REMOVE LEAVES, PINE
NEEDLES, GRASS CLIPPINGS, MULCH, OR ANY DEBRIS THAT HAS ACCUMU-
LATED ON THE LIGHT BULB, LENS, OR BODY OF THE FIXTURE.
ASSEMBLY AND INSTALLATION
1) Determine desired location for mounting fixture.
2) At desired location, hammer stake (A) into ground. To avoid
damage to stake, place a board on top of stake while hammering.
If ground is hard and stake is difficult to install, make a cross
cut in ground using a flat shovel.
3) Clear away area in ground at wireway slot (B) in top of stake (A).
4) Lay 12V cable into wireway slot (B) and screw stem (D) into
stake (A). If assembly does not look straight, adjust by pushing
or pulling on stake only.
5) Screw shade (C) onto stem (D).
6) TURN OFF POWER.
7) Makewireconnectionsusingsuppliedwirenutsfollowing
instructions on bag.
DEFLECTOR INSTRUCTIONS
1) Fixtures with a center mount stem are provided with a deflector
(E), black (installed) and white.
2) Deflector is removable or changeable if desired.
3) To remove/install/change deflector – if fixture is already
installed:
1) Turn off and unplug transformer.
2) Disconnect wire connections.
3) Remove fixture from stake.
4) Unscrew and remove LED module from stem.
5) Remove, change, or install deflector.
6)Re-attachLEDmoduletostem.
7)Installxtureperinstructionsabove.
4) To remove/install/change deflector – if fixture is not installed:
1) Unscrew and remove LED module from stem.
2) Remove, change, or install deflector.
3)Re-attachLEDmoduletostem.
4) Install fixture per instructions above.
Date Issued: 12/26/14 IS-15810R-US
A
B
D
For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page
Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
C
E

Summary of content (2 pages)