Installation Guide

SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
This xture is intended for installation in accordance with the National
Electric Code (NEC) and Local code specications. Failure to adhere to
these codes and instructions may result in serious injury and/or property
damage and will void the warranty.
WARNING – RISK OF ELECTRIC SHOCK
• Donotmountluminairewithin10feet(3m)ofaswimmingpool,spaor
fountain.
• ThisxtureistobeusedonlywithaKichler
®
lowvoltagelightingpower
unit(transformer)ratedamaximum15volts,300Wpersecondary(25AMPS)
NOTE: IfadditionalDirectBurialwireisneeded,contactyourlocalKichler
®
landscapedistributor.
•8GAwirecanbepurchasedinlengthof250’(76M),15503-BK.
•10GAwirecanbepurchasedinlengthof250’(76M),15504-BK.
•12GAwirecanbepurchasedinlengthsof100’(30M),15501-BK;250’
(76M),15502-BK;500’(152M),15505-BK;and1000’(304M),15506-BK.
DateIssued:1/13/12 IS-16030-US
For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page
Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page
SPHERE
RETAINING
SCREWS
TORNILLOSDE
RETENCIÓNDE
LAESFERA
GLASS
SEALINGRING
ANILLO
OBTURADOR
DEVIDRIO
GLASS
VIDRIO
GASKET
JUNTA
SPHERE
ESFERA
THREADEDSTAKE
ESTACAROSCADA
FIXTURE ASSEMBLY AND INSTALLATION
1. Turnoffpower.
2. Determineddesiredlocationofxtureanddighole.Holeshouldbe9"
(diameter)x6"(deep)ifworkinginsoftsoil,suchassand.Ifworkingin
hardorcompactedsoil,suchasclay,diga9"(diameter)x10"(deep)hole.
3. If installing in soft soil:Usethethreadedstaketodigintotheground
andtemporarilystabilizethexture.
If installing in hard soil:Fillthebottomoftheholewithapproximately3"
(76mm)ofpeagravel.Placethextureinholeandbackllaroundthe
xturewithsoil,uptothewireexithole.
4. MakewireconnectionsusingsuppliedQuicDisc™followingtheinstructions
below,orusingotherapprovedwiringconnectionmethod(notsupplied.)
Thexturewireisnotintendedfordirectburial.Accordingtotherequirements
oftheNationalElectricCode(NEC),directburialratedwireistobeburied
aminimumof6"[152mm]beneaththesurfaceoftheground.
5. To aim the beam:Removetheglasssealantringbyremovingthesix(6)
screwsontopofthexture.Loosenthescrewsonthesphereretaining
ringuntilthespherebecomesunxed.Aimthebeamasdesired.(upto
15°)Re-tightenthescrewsonthesphereretainingringuntilthesphereis
secureanddoesnotrotate.Cleansealingsurface,andreplaceglass,
gasket,andglasssealingring.Installandtorquescrewsintriangular
pattern,followingthenumbersscrewsholes1-6.
6. Backllaroundthexturewithsoil.
SOIL
SUELO
FOR INSTALLATION IN SOFT SOILPARA
INSTALACIÓN EN SUELOS BLANDOS
SOIL
SUELO
FOR INSTALLATION IN HARD SOIL
PARA INSTALACIÓN EN SUELOS DUROS
3"(76MM)
OFPEAGRAVEL
3”(76MM)DE
GRAVADERÍO
START
INICIO
TIGHTEN SCREWS IN TRIANGULAR PATTERN SHOWN ABOVE.
AJUSTE LOS TORNILLOS EN FORMA TRIANGULAR TAL COMO SE
MUESTRA ANTERIORMENTE.
QUIC DISC
WIRING INSTRUCTIONS
Turnoffpower.
Thefulllengthofthe18GAxturewiremaybeusedtoconnectwiththe10GAor12GAcableprovidedthefollowingconditionsaremet:
•Wiringistobeprotectedbyroutingclosetothextureoraccessoryorsecuredtoabuildingstructuresuchashouseordeck.
• 18GAxturewiringistobecutoffsothatitisattachedtotheconnectorwithin6inchesofthextureorbuildingstructure.
• Ifitisnecessarytomaketheconnectionsunderground,thennomorethan6inchesofthe18GAxturewireistobeburied.
TheQuicDisc
connectorisdesignedtoinstallonextureandaccommodatesone18GAxturewireandone10GAorone12GAsupplywire.
Placethe10gaugesupplywireacrosstheareamarked10GAonQuicDisc
orplacethe12gaugesupplywireacrosstheareamarked12GA
onQuicDisc
.
Placethe18gaugexturewireacrosstheareamarked18GAontheQuicDisc
.Afterthewiresareinplace,connectathetopoftheQuic
Disc
tothebasewithsuppliedscrew,makingsurethatthewiresremainatinthebottomportionoftheQuicDisc
,andthescrewistightened
allthewaydown.
Thecoppercontactswillautomaticallypiercethewires’insulation.Excess18GAxturewirethatsticksouttheendoftheQuicDisc
istobecutoff.
Makenootherwiringconnectionstothe18GAxturewire.