User Manual

12) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.
13) Push fixture to ceiling, carefully passing mounting screws
through holes in canopy.
14) Secure fixture to ceiling with threaded caps.
15) Set glass down over socket.
16) Thread socket ring onto socket. (DO NOT over tighten.)
17) Insert recommended bulb. CAUTION: DO NOT touch bulb
with bare hands. If this happens, clean bulb with denatured
alcohol and a lint free cloth.
18) Slip glass sleeve over bulb.
LOOP/CHAIN LINK MOUNT
1) Follow steps 1, 2 and 3 from Rigid Stem Mount Instructions.
2) Screw loops onto end of each threaded pipe at top of each
stem.
3) Add one chain link to each loop and add second loop to each
chain link.
4) Screw threaded pipe into end of each second loop.
5) Pass each threaded pipe on loops through holes in canopy.
6) Slip one lockwasher over end of each threaded pipe protruding
from inside of canopy.
7) On one threaded pipe screw hexnut onto end of threaded pipe.
8) On other threaded pipe slip end of safety cable then remaining
lockwasher over end of threaded pipe. Screw hexnut onto
threaded pipe.
9) Follow steps 8 - 18 from Rigid Stem Mount Instructions.
IMPORTANT SAFETY INSTRUCTIONS
LIGHTED BULB IS HOT!
WARNING: To reduce the risk of FIRE or INJURY TO PERSON:
• Turnoffandallowtocoolbeforereplacingbulb.
• BulbgetsHOTQUICKLY!Contactswitchonlywhenturningoff.
• DONOTremaininlightifskinfeelswarm.(Lightisintense,
may cause “sunburn”)
• DONOTlookdirectlyatlightedbulb.
• Keepmaterialsawayfrombulbthatmayburn.
• UseONLYwithwattagespeciedorlower.
• DONOTtouchbulbatanytime,useasoftcloth.Oilfromskin
may damage bulb.
• DONOToperatexturewithmissingordamagedglass.
RIGID STEM MOUNT
1) Pass wire through stems and screw stems into couplings on
top of fixture body. NOTE: Thread locking compound must be
applied to all stem threads as noted with symbol (3) to prevent
accidental rotation of fixture during cleaning, relamping, etc.
2) Pass fixture wire through remaining stems and screw stems
together.
3) Screw small threaded pipe onto top of stems.
4) Pass holes in canopy over threaded pipe on top of stems.
5) Slip one lockwasher over end of each threaded pipe protruding
from inside of canopy.
6) On one threaded pipe screw hexnut onto end of threaded pipe.
7) On other threaded pipe slip end of safety cable then remaining
lockwasher over end of threaded pipe. Screw hexnut onto
threaded pipe.
8) TURN OFF POWER.
IMPORTANT:Beforeyoustart,NEVERattemptanywork
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s), that control the power to the fixture or room that
you are working on.
c) Place the wall switch in the “OFF” position. If the fixture to
be replaced has a switch or pull chain, place those in the
“OFF” position.
9) Find the appropriate threaded holes on mounting strap.
Assemble mounting screws into threaded holes.
10) Attach mounting strap to outlet box. (Screws not provided).
Mounting strap can be adjusted to suit position of fixture.
11) Groundinginstructions:(SeeIllus.AorB).
A) On fixtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Put
ground wire from outlet box under cupped washer and
green ground screw and thread screw into hole
in mounting strap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wire to outlet box ground wire with wire connector, (not
provided) after following the above steps. Never connect
ground wire to black or white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
IS-42018-USDate Issued: 1/04/13
LOOP/CHAIN LINK
LAZO/ ESLABÓN DE CADENA
GLASS
VIDRIO
CANOPY
ESCUDETE
STEM
VARILLA
3
LOOP
ANILLO
CHAINLINK
ESLABÓNDE
CADENA
STEM
VARILLA
RIGID STEM MOUNT
MONTAJE DEL VÁSTAGO NERVADO
THREADEDCAP
TAPAROSCADA
THREADED
CAP
TAPAROSCADA
BULB
BOMBILLA
GLASSSLEEVE
CAMISADEVIDRIO
SOCKETRING
ANILLODELCASQUILLO
SAFETYCABLE
CABLEDESEGURIDAD
3
SAFETYCABLE
CABLEDE
SEGURIDAD