Rana Instruction Manual

6
60” Rana
Code switch
HI
MED
LOW
FAN OFF
ON ECE
1 2 3 4
ON ECE
1234
ON
6. INSTALLATION OF SAFETY SUPPORT
(Required for Canadian installation ONLY)
A safety support cable is provided to help prevent the
ceiling fan from falling, please install it as follows.
Step 1. Attach the provided wood screw and washers
to the ceiling joist next to the mounting bracket but do
not tighten. (Fig. 12)
Step 2. Adjust the length of the safety cable to reach
the screw and washers by pulling the extra cable
through the cable clamp until the overall length is
correct, put the end of the cable back through the
cable clamp, forming a loop at the end of the cable.
Tighten the cable clamp securely. Now, put the loop
in the end of the safety cable over the wood screw
securely.
NOTE: Although the safety support cable is required
for Canadian installations only. It’s a good idea to
make the attachment with any installation.
7. ELECTRICAL CONNECTIONS
WARNING: To avoid possible electrical shock, be
sure you have turned off the power at the main circuit
panel.
NOTE: The frequencies on your receiver and wall
transmitter have been preset at the factory. Before
installing the receiver, make sure the dip switches on
the receiver and wall transmitter are set to the same
frequency. (Fig. 13)
Step 1. Insert the receiver into the ceiling mounting
bracket with the at side of the receiver facing the
ceiling. (Fig. 14)
For best performance, make sure the Black antenna,
on the end of the receiver, remains extended and not
tangled with any of the electrical wires.
Step 2. Motor to Receiver Electrical connections:
Connect the black wire from the fan to the black wire
marked “TO MOTOR L” on the receiver. (Fig. 15)
Fig. 14
Fig. 13
Fig. 12
Receiver
Hanger
bracket
Hanger bracket
Safety cable
Attach safety cable
to ceiling joist with
screw and washer