Instruction Sheet
5) Make wire connections (connectors not provided.) Reference chart
below for correct connections and wire accordingly.
IMPORTANT: For xtures 42172, 42173 and 42174, the wires on these
xtures will be clear or silver. The “Black” xture wire should be marked with
an “L”. The “White” xture wire should be marked with an “N”. The “White”
supply wire does have a thin white wire that runs through the clear/silver
wire.
6) Push xture to ceiling, carefully passing mounting screws through holes.
7) Secure xture to ceiling with threaded balls.
8) Insert recommended bulb. CAUTION: DO NOT touch bulb with bare
hands. If this happens, clean bulb with denatured alcohol and a lint free
cloth.
9) Thread glass sleeve onto socket. (DO NOT over tighten.)
10) Lower each crystal rod down through top and bottom triangular opening
on xture. Peg on crystal will keep crystal in place on xture.
Adjusting position of xture after installation for leveling purposes of
one inch or less:
NOTE: Center cable will adjust height of xture. Side cables will adjust level
of xture.
TO RAISE FIXTURE: Push cable up into xture body. Release cable and
cable will lock into place.
TO LOWER FIXTURE: Push button in on cable adjuster and pull cable
down. Release button to lock cable in place.
NOTE: With button pushed in cable will raise and lower. Without button
pushed in cable will only raise up and lock in place. (SEE: CABLE ADJUST-
MENT DETAIL)
IMPORTANT SAFETY INSTRUCTIONS
LIGHTED BULB IS HOT!
WARNING: To reduce the risk of FIRE or INJURY TO PERSON:
• Turn off and allow to cool before replacing bulb.
• Bulb gets HOT QUICKLY! Contact switch only when turning off.
• DO NOT remain in light if skin feels warm. (Light is intense, may cause
“sunburn”)
• DO NOT look directly at lighted bulb.
• Keep materials away from bulb that may burn.
• Use ONLY with wattage specied or lower.
• DO NOT touch bulb at any time, use a soft cloth. Oil from skin may damage
bulb.
• DO NOT operate xture with missing or damaged glass.
1) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work without
shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your home. Place the
main power switch in the “OFF” position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker switch(s),
that control the power to the xture or room that you are working on.
c) Place the wall switch in the “OFF” position. If the xture to be re
placed has a switch or pull chain, place those in the “OFF” position.
2) Assemble mounting screws into threaded holes in mounting strap.
3) Attach mounting strap to outlet box. (Screws not provided)
4) Grounding instructions: (See Illus. A or B).
A) On xtures where mounting strap is provided with a hole and two
raise dimples. Wrap ground wire from outlet box around green
ground screw, and thread into hole.
B) On xtures where a cupped washer is provided. Put ground wire
from outlet box under cupped washer and green ground screw
and thread screw into hole in mounting strap.
If xture is provided with ground wire. Connect xture ground wire to
outlet box ground wire with wire connector, (not provided) after following
the above steps. Never connect ground wire to black or white power
supply wires.
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
Date Issued: 6/8/12 IS-42173-US
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
MOUNTING STRAP
ABRAZADERA DE MONTAJE
SIDE CABLE
CABLE LATERAL
SIDE CABLE
CABLE LATERAL
PRESSED
CABLE ADJUSMENT DETAIL
EL DETALLE DE AJUSTE DEL CABLE
NOT
PRESSED
UP & DOWN
UP ONLY
CRYSTAL ROD
VARILLA DE CRISTAL
CANOPY
ESCUDETE
THREADED BALL
BOLA ROSCADA
TRIANGULAR OPENING
APERTURA TRIANGULAR
1) If strain relief is not assembled to wires, pull wires up through strain
relief and close strain relief.
2) Holding strain relief with pliers, pinch sides of strain relief and push
strain relief up through hole in canopy. (REF: FIG. 2)
3) If strain relief is assembled to canopy, to remove strain relief to
release strain on wires, from inside canopy pinch sides of strain relief
with pliers. Push strain relief down through hole in canopy. (REF: FIG. 1)
4) Open strain relief and pull wires down. Close strain relief and replace
strain relief to canopy (see step #2).
CAUTION: Take care not to nick, cut or damage wire.
STRAIN RELIEF
PRENSACABLE
WIRE
CABLE
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
CANOPY
ESCUDETE
PLIERS
PINZA
STRAIN RELIEF
PRENSACABLE
STRAIN RELIEF
PRENSACABLE
PLIERS
PINZA
CANOPY
ESCUDETE
WIRE
CABLE
FIG. 1
FIG. 2
STRAIN RELIEF
PRENSACABLE