1) Pass wire through stems[A] and screw stems into
couplings[B] on top of xture body. NOTE: Thread locking
compound must be applied to all stem threads as noted with
symbol () to prevent accidental rotaon of xture during
cleaning,relamping, etc.
2) Pass xture wire through remaining stems and screw stems
together.
3) On each side of xture, pass xture wire through one small
threaded pipe[C]. Screw each small threaded pipe onto top of
stem on each side.
4) On each side of xture, pass xture wires through each hole in
canopy[D]. Lower canopy down towards stems. Pass each hole
in canopy over end of each threaded pipe on top of stems.
5) On one side of xture, pass xture wire through
lockwasher[E]. Thread lockwasher onto end of threaded
pipe protruding from inside canopy. Pass xture wire through
hexnut[F]. Thread hexnut onto end of threaded pipe.
6) On other side of xture, pass xture wire through loop on
end of safety cable[G]. Slip loop on safety cable over end of
threaded pipe protruding from inside of canopy. Pass xture
wire through lockwasher. Thread lockwasher onto end of
threaded pipe protruding from inside canopy. Pass xture wire
through hexnut. Thread hexnut onto end of threaded pipe.
7) Find the appropriate threaded holes on mounng strap[H].
Assemble mounng screws[I] into threaded holes.
8) Aach mounng strap to outlet box[J] using the strap
mounng screws[N]. Mounng strap can be adjusted to suit
posion of xture.
9) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole
and two raised dimples, wrap ground wire from outlet
box around green ground screw, and thread into hole.
b) On xtures where a cupped washer is provided, aach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounng strap.
If xture is provided with ground wire, connect xture ground
wire to outlet box ground wire with wire connector (Not
provided) aer following the above steps. Never connect
ground wire to black or white power supply wires.
10) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply Wire
to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other than
green) with silver conductor
*Note: When parallel wire (SPT 1 &
SPT 2) are used. The neutral wire
is square shaped or ridged and the
other wire will be round in shape or
smooth (See illus.)
Neutral Wire
11) Push xture to ceiling, carefully passing mounng screws
through holes in canopy. NOTE: Be certain wires do not get
pinched between mounng strap and canopy.
12) Secure xture to ceiling with lock-up knobs[K].
Installaon Instrucons – Loop/Chain Link Mount
1) Follow steps 1 and 2 from Rigid Stem Mount Instrucons.
2) Thread one small threaded pipe[C] into end of each small
loop[L].
3) Pass xture wire through rst loop. Thread rst loop onto end
of each last stem.
4) On one side of xture, pass xture wire through second loop
and through hole in canopy[D]. Pass threaded pipe at end of
second loop through hole in canopy.
5) Pass xture wire through lockwasher[E]. Thread lockwasher
onto end of threaded pipe protruding from inside canopy.
6) Pass xture wire through hexnut[F]. Thread hexnut onto end
of threaded pipe.
7) On other side of xture, pass xture wire through second
loop and through hole in canopy. Pass threaded pipe at end of
second loop through hole in canopy.
8) Pass xture wire through loop on end of safety cable[G]. Slip loop
on safety cable over end of threaded pipe protruding from inside
of canopy.
9) Pass xture wire through lockwasher. Thread lockwasher onto
end of threaded pipe protruding from inside canopy.
10) Pass xture wire through hexnut. Thread hexnut onto end of
threaded pipe.
11) Aach locking link[M] to small loop at end of each stem and to
each loop on canopy.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Stems
[B] Couplings
[C] Small
Threaded Pipe
[D] Canopy
[E] Lockwasher
[F] Hexnut
[G] Safety Cable
[H] Mounting
Strap
[I] Mounting
Screws
[J] Outlet Box
[K] Lock-up Knobs
[L] Small Loop
[M] Locking Link
[N] Strap
Mounting
Screws
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.