Installation Sheet
Table Of Contents
IS-43596-US
Estamos aquí para ayudarle 866-558-5706
Horario: Lunes-Viernes 9am a 5pm EST (hora ocial del este)
protruding from inside of canopy. Pass xture wire
through lockwasher. Place lockwasher onto end of
threaded pipe protruding from inside of canopy. Pass
xture wire through hexnut[E].
6) (If second loop is already aached to canopy, proceed
to next step). Pass threaded pipe at end of second loop
through hole in canopy. Thread lockwasher[L] onto
threaded pipe protruding from inside canopy. Pass
xture wire through hole in hexnut and thread hexnut[E]
onto end of threaded pipe.
7) Aach chain link[F] to small loop at end of stem and to
loop on canopy.
8) Find the appropriate threaded holes on mounng
strap[G]. Assemble mounng screws[H] into threaded
holes.
9) Aach mounng strap to outlet box[I] using the strap
mounng screws[M]. The mounng strap can be
adjusted to suit posion of xture.
10) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (not provided.) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
11) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (see illus.)
Neutral Wire
12) Push xture to ceiling, carefully passing mounng screws
through holes in canopy[J]. NOTE: Be certain wires do
not get pinched between canopy and ceiling.
13) Use knobs[K] and lockwashers[L] to secure canopy.
Tighten to secure.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Coupling
[B] Stem
[C] Short
Threaded
Tubes
[D] First Loop
[E] Hexnut
[F] Chain Link
[G] Mounting
Strap
[H] Mounting
Screws
[I] Outlet Box
[J] Canopy
[K] Knobs
[L] Lockwashers
[M] Strap
Mounting
Screws
[N] Safety Cable
1) Pass xture wire from the coupling[A] on top of xture
through a stem[B] and screw stem into coupling. NOTE:
Thread locking compound must be applied to all stem
threads as noted with symbol (4) to prevent accidental
rotaon of xture during cleaning, relamping, etc.
2) Pass xture wire through desired amount of stems and
screw stems together using supplied short threaded
tubes[C].
3) Pass xture wire from last stem through rst loop[D].
Thread rst loop onto end of last stem.
4) Pass xture wire through second loop and through hole
in canopy[J].
5) Slip loop of safety cable[N] over end of threaded pipe
Installaon Instrucons (connued)
I
G
M
J
D
B
C
E
H
I
A
►
►
L
K
L
►
N
►