1) Attach chain to fixture. Fixture loop has one chain
link factory installed. Chain has one locking link at
each end. Unscrew coupling on locking link and slip
over link attached to loop. Screw coupling closed.
2) Slip threaded ring (N) then canopy (M) onto chain (W)
3) Attach chain (with fixture connected) to bottom of
screw collar loop following the same procedure as
in step 1.
4) Weave electrical wire, ground wire and safety cable
through chain links no more than 3 inches apart.
5) Pass electrical wire ground wire and safety cable
through threaded ring (N), canopy (M), one of the
slots in screw collar loop (L) and into outlet box.
6) Pass safety cable through hole (See sec. 1)
7) In area above outlet box wrap cable around one
of the 2 x 4’s erected in section 1 and pull cable taut.
8) Secure cable with (2) clamps provided.
NOTE: Cable is not to be used as the only means
of fixture support. Please follow independent
mounting instructions completely.
8) Connect fixture ground wire and ground wire
attached to threaded rod (B or P) to outlet box
ground wire with wire connector (not provided).
Never connect ground wire to black or white power
supply wires.
10) Make wire connections (connectors not provided).
Reference chart below for correct connections and
wire accordingly.
11) Raise canopy (M) to ceiling.
12) Secure canopy (M) in place by screwing threaded
ring (N) onto screw collar loop (L)
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
1) Thread end of threaded pipe without hexnut into
coupling on top of fixture.
2) Slip tube down over threaded pipe on top of fixture.
3) Pass fixture wire through hole in check ring. Pass hole
in check ring down over end of threaded pipe protruding
from tube. Place check ring on top of tube.
4) Pass fixture wire through hole in bottom of top loop.
Thread top loop onto threaded pipe protruding from
check ring.
For ease in assembly, proceed to section 3.
Remaining steps in fixture assembly can be completed
easier with fixture hanging.
5) Starting with the long metal rod, slip hook at top of
long metal rod through hole along edge of ring. The
pattern for the rods is long metal rod, glass rod, short
metal rod, glass rod. Repeat this pattern until all rods
are attached.
17) Attach one glass sphere to the end of each long metal
rod and each short metal rod attached to fixture.
18) Thread finial onto threaded pipe on bottom of fixture
body.
LOOP
ANILLO
HEXNUT
TUERCA HEXAGONAL
COUPLING
ACOPLAMIENTO
THREADED PIPE
TUBO ROSCADO
STRUCTURAL BRIDGING
MEMBER
MIEMBRO DE CONEXIÓN
ESTRUCTURAL
CLAMP
GRAMPA
SAFETY CABLE
CABLE DE APOYO
P
L
X
M
N
W
IS-43758-US
TUBE
TUBO
CHECK RING
ANILLO DE SEGURIDAD
LONG METAL ROD
BARRA DE METAL
LARGO
SHORT METAL ROD
BARRA DE METAL
CORTO
GLASS ROD
BARRA DE VIDRIO
GLASS SPHERE
ESFERA DE VIDRIO
FINIAL