Installation Sheet

Date Issued: 09/26/17 IS-44076-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
1) Passxturewirethroughdesiredamountofstems[1]and
screwstemstogetherusingsuppliedshortthreadedtubes[2].
2) Passxturewirefromthecouplingontopofxturethrough
endofstem[2].Threadendofstemontoxturebody.NOTE:
Threadlockingcompoundmustbeappliedtoallstemthreads
asnotedwitharrowsymboltopreventaccidentalrotationof
xtureduringcleaning,relamping,etc.
3) Passxturewirethroughdesiredstemsandscrewstems
together
4) Threadonesmallthreadedpipe[12]intoendofloop[13].
5) Passxturewirethroughloop.Threadloopontoendoflast
stem.
6) Takeathreadedpipe[7]frompartsbagandscrewinscrew
collarloop[10]aminimumof6mm(1/4”).Lockintoplacewith
hexnut[8].
7) Runanotherhexnutdownthreadedpipealmosttouching
rsthexnut.Nowscrewthreadedpipeintomountingstrap[3].
Mountingstrapmustbepositionedwithextrudedthreadfaced
intooutletbox[6].Threadedpipemustprotrudeoutthebackof
mountingstrap.Screwthirdhexnutontoendofthreadedpipe
protrudingfrombackofmountingstrap.
8) Connectmountingstraptooutletboxusingstrapmounting
screws[5].
9) Unscrewthethreadedringfromscrewcollarloop[10].Take
canopy[4]andpassoverscrewcollarloop.Approximately
onehalfofthescrewcollarloopexteriorthreadsshouldbe
exposed.Adjustscrewcollarloopbyturningassemblyupor
downinmountingstrap.Removecanopy.
10)Afterdesiredpositionisfound,tightenbothtopandbottom
hexnutsupagainstthebottomandtopofthemountingstrap.
11)Slipcanopyoverscrewcollarloopandthreadonthreadedring.
Attachchain[11](withxtureconnected)tobottomofscrew
collarloop.Unscrewthreadedring[9],letcanopyandthreaded
ringslipdown.(Closechainlinkendstogetherusingchainpli-
ersorpaddedplierstopreventdamagetonish.)
12)Weaveelectricalwireandgroundwirethroughchainlinks[11]
nomorethan3inchesapart.Passwirethroughthreadedring,
canopy,screwcollarloop,threadedpipeandintooutletbox.
13)Groundinginstructions:(SeeIllus.AorB).
A) Onxtureswheremountingstrapisprovidedwitha
holeandtworaiseddimples.Wrapgroundwirefrom
outletboxaroundgreengroundscrew,andthreadinto
hole.
B) Onxtureswhereacuppedwasherisprovided.Attach
groundwirefromoutletboxundercuppedwasherand
greengroundscrew,andthreadintomountingstrap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wiretooutletboxgroundwirewithwireconnectorafterfollow-
ingtheabovesteps.Neverconnectgroundwiretoblackor
whitepowersupplywires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
1
2
4
3
8
9
10
11
12
7
6
5
13
14
15
14)Makewireconnections.Referencechartbelowforcorrectcon-
nectionsandwireaccordingly.
15)Raisecanopytoceiling.
16)Securecanopyinplacebytighteningthreadedringontoscrew
collarloop.
17)Insertrecommendedbulbs.
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire

Summary of content (2 pages)