Installation Sheet
Table Of Contents
IS-44110-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
**NOTE: A minimum of one 12 inch stem per side MUST be used in mounng of
xture.**
1) Pass wire through stems[A] and small threaded tubes[B] and screw stems
into couplings[Q] on top of xture body[P]. NOTE: Thread locking compound
must be applied to all stem threads as noted with symbol (4) to prevent
accidental rotaon of xture during cleaning,relamping, etc.
2) Pass xture wire through remaining stems and screw stems together.
3) On each side of xture, pass xture wire through one small threaded pipe[L].
Screw each small threaded pipe onto top of stem on each side.
4) On each side of xture, pass xture wires through each hole in canopy[H].
Lower canopy down towards stems. Pass each hole in canopy over end of
each threaded pipe on top of stems.
5) On one side of xture, pass xture wire through lockwasher[E]. Thread
lockwasher onto end of threaded pipe protruding from inside canopy. Pass
xture wire through hexnut[F]. Thread hexnut onto end of threaded pipe.
6) Slip loop on safety cable[D] over end of threaded pipe protruding from inside
of canopy. Pass xture wire through lockwasher. Thread lockwasher onto end
of threaded pipe protruding from inside canopy. Pass xture wire through
hexnut. Thread hexnut onto end of threaded pipe.
7) Find the appropriate threaded holes on mounng strap[G]. Assemble
mounng screws[N] into threaded holes.
8) Aach mounng strap to outlet box[C] using the strap mounng screws[I].
Mounng strap can be adjusted to suit posion of xture.
9) Aach safety cable to outlet box.
10) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised
dimples, wrap ground wire from outlet box around green ground screw,
and thread into hole.
b) On xtures where a cupped washer is provided, aach ground wire from
outlet box under cupped washer and green ground screw, and thread
into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet
box ground wire with wire connector (Not provided) aer following the above
steps. Never connect ground wire to black or white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
11) Make wire connecon. Reference chart below for correct connecons and
wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
12) Push xture to ceiling, carefully passing mounng screws through holes in
canopy. NOTE: Be certain wires do not get pinched between mounng strap
and canopy.
13) Secure xture to ceiling with lockwashers[J] and lock-up knobs[K] as shown.
14) Install the ve (5) long and the ve (5) short candle sleeves[O] onto the
correct sockets.
15) Insert recommended bulbs. (Not supplied)
Installaon Instrucons – Loop/Chain Link Mount
**NOTE: A minimum of one 12 inch stem per side MUST be used in mounng of
xture.**
1) Follow steps 1 and 2 from Rigid Stem Mount Instrucons.
2) Thread one small threaded pipe[L] into end of each small loop[R].
3) Pass xture wire through rst loop. Thread rst loop onto end of each last
stem.
4) On one side of xture, pass xture wire through second loop and through
hole in canopy[H]. Pass threaded pipe at end of second loop through hole in
canopy.
5) Pass xture wire through lockwasher[E]. Thread lockwasher onto end of
threaded pipe protruding from inside canopy.
6) Pass xture wire through hexnut[F]. Thread hexnut onto end of threaded
pipe.
7) On other side of xture, pass xture wire through second loop and through
hole in canopy. Pass threaded pipe at end of second loop through hole in
canopy.
8) Pass xture wire through loop on end of safety cable[D]. Slip loop on safety
cable over end of threaded pipe protruding from inside of canopy.
9) Pass xture wire through lockwasher. Thread lockwasher onto end of
threaded pipe protruding from inside canopy.
10) Pass xture wire through hexnut. Thread hexnut onto end of threaded pipe.
11) Aach locking linkto small loop at end of each stem and to each loop on
canopy and close the open chain link [M] by placing a piece of cloth over the
open link and using a pair of pliers gently squeeze the link closed.
12) Follow steps 7 - 15 from Rigid Stem Mount Instrucons.
Fixture Diagram
Parts List
[A] Stems
[B] Small Threaded Tubes
[C] Outlet Box
[D] Safety Cable
[E] Lockwasher
[F] Hexnut
[G] Mounting Strap
[H] Canopy
[I] Strap Mounting
Screws
[J] Lockwashwers
[K] Lock-up Knobs
[L] Small Threaded Pipe
[M] Chain Link
[N] Mounting Screws
[O] Candle Sleeves
[P] Fixture Body
[Q] Couplings
[R] Small Loops
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before
starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical
Code (NEC) and all local code specicaons. If you are not familiar with code
requirements, installaon by a cered electrician is recommended.
Installaon Instrucons – Rigid Stem Mount
Installaon Instrucons – Rigid Stem Mount (connued)