2) Pass xture wire through end of swivel[C] without
threaded pipe. Thread that end of swivel onto end of last
stem. Note direcon of swivel in accordance with ceiling.
3) Pass xture wire through hole in canopy[D]. Pass
threaded pipe on end of swivel up through hole in
canopy.
4) Pass xture wire through lockwasher[E] . Thread
lockwasher onto end of threaded pipe protruding from
inside canopy.
5) Pass xture wire through hexnut[F]. Thread hexnut onto
end of threaded pipe.
6) Find the appropriate threaded holes on mounng
strap[G]. Assemble mounng screws[H] into threaded
holes.
7) Aach mounng strap to outlet box[I] using the strap
mounng screws[P]. Mounng strap can be adjusted to
suit posion of xture.
8) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
9) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
10) Push xture to ceiling, carefully passing mounng screws
through holes in canopy. NOTE: Be certain wires do not
get pinched between canopy and ceiling.
11) Use knobs[J] and lockwashers[K] to secure canopy.
Tighten to secure.
12) Carefully raise glass[L] to the xture. Slip the smaller
opening over the socket[M] and t the glass against the
socket.
13) Thread socket ring[N] onto socket. Tighten socket ring to
secure glass in place. (DO NOT over ghten.)
14) Insert recommended bulb (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Stems
[B] Short
Threaded
Tubes
[C] Swivel
[D] Canopy
[E] Lockwasher
[F] Hexnut
[G] Mounting
Strap
[H] Mounting
Screws
[I] Outlet Box
[J] Knobs
[K] Lockwashers
[L] Glass
[M] Socket
[N] Socket Ring
[O] Fixture body
[P] Strap
Mounting
Screws
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
1) Pass xture wire through desired amount of stems[A]
and screw stems together using supplied short threaded
tubes[B]. Thread the assembled stems into the top of
the xture body[O].
NOTE: Thread locking compound must be applied to
all stem threads as noted with (4) symbol to prevent
accidental rotaon of xture during cleaning, relamping,
etc.
Installaon Instrucons (connued)
I
G
D
H
K
J
P
A
B
C
E
F
L
N
O
M