Installation Sheet

Date Issued: 09/15/17 IS-45871-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Attach mounting strap[1] to outlet box[2]. Mounting strap can
be adjusted to suit position of xture.
2) Grounding instructions: (See Illus. A or B)
A) On xtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) On xtures where a cupped washer is provided. Put
ground wire from outlet box under cupped washer and
green ground screw and thread screw into hole in mount-
ing strap.
If xture is provided with ground wire. Connect xture ground
wire to outlet box ground wire with wire connector, after follow-
ing the above steps. Never connect ground wire to black or
white power supply wires.
3) Make wire connections. Reference chart below for correct con-
nections and wire accordingly.
4) Push xture to wall. Be sure not to pinch wires between wall
and canopy of xture.
5) Screw in two (2) mounting screws[3]: one on top of canopy[4]
and the other into the bottom of canopy.
6) Carefully raise glass[5] to the xture. Slip the smaller opening
over the socket[6] and t the glass against the socket.
7) Thread socket ring[7] onto socket. Tighten socket ring to se-
cure glass in place. (DO NOT over tighten.)
8) Repeat for remaining sockets (if necessary).
9) Screw in recommended bulb (not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wir es (SPT I & SPT II)
are used. The neutral wir e is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
4
7
6
5
1
3
2
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fuse
box before starting and during the installation.