Instructions / Assembly

For warranty information please visit: kichler.com/warranty
REV 12-NOV-2021
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTIONS
CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before
starting and during the installation.
WARNING:
1. This fixture is intended for installation in accordance with the National
Electrical Code (NEC) and all local code specifications. If you are not familiar
with code requirements, installation by a certified electrician is recommended.
Failure to adhere to these codes and instructions may result in serious injury
and/or property damage and will void the warranty.
CLEANING:
• Always be certain that electric current is turned o before cleaning.
• Only a soft damp cloth should be used. Harsh cleaning products may damage
the finish.
INSTALLATION INSTRUCTIONSFIXTURE DIAGRAM
IS-52464-US
PARTS LIST
[A] Short Threaded
Tubes (Attached to
Stems [G])
[B] Stems (2-12”, 2-6”
with Short Threaded
Tubes [F] installed)
[C] Swivel (Attached to
Canopy)
[D] Canopy
[E] Lock Washer (Qty. 2)
[F] Knob (Qty. 2)
[G] Strap Mounting
Screw (Qty. 2)
[H] Mounting Screw
(Qty. 2)
[I] Outlet Box (Not
Supplied)
[J] Mounting Strap
[K] Coupling
[L] Main Body
[M] Glass Shade
[N] Glass Shade
Retaining Ring
[O] Large Flat Washer
[P] Socket
[Q] Threads
1. Pass fixture wire from coupling[K] on top of main body through desired number of short threaded
tubes[A] and stems[B].
2. Screw stems together using short threaded tubes.
3. Thread assembled stems into coupling[K] on top of main body.
NOTE: Thread locking compound must be applied to all stem threads as noted with (4) symbol to
prevent accidental rotation of fixture during cleaning, relamping, etc.
4. Pass fixture wire from last stem through end of swivel[C] and into canopy[D]. Thread the end of
swivel into end of last stem. Note direction of swivel in accordance with ceiling.
5. Find the appropriate threaded holes on mounting strap[J] that align with hole distance in
canopy[D]. Assemble mounting screws[H] into threaded holes starting from the outlet box side.
6. Attach mounting strap to outlet box[I] using the supplied strap mounting screws[G]. Mounting
strap can be adjusted to suit position of fixture.
7. Grounding instructions: (See Illus. a or b).
a. On fixtures where mounting strap is provided with a hole and two raised dimples, wrap
ground wire from outlet box around green ground screw, and thread into hole.
b. On fixtures where a cupped washer is provided, attach ground wire from outlet box under
cupped washer and green ground screw, and thread into mounting strap.
If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with
wire connector after following the above steps. Never connect ground wire to black or white power
supply wires.
8. Make wire connections. Reference chart below for correct connections and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.) Neutral Wire
9. Push fixture to ceiling, carefully passing mounting screws through holes in canopy.
NOTE: Be certain wires do not get pinched between mounting strap and canopy or canopy and
ceiling.
10. Use lock washers[E] and knobs[F] to secure canopy[D]. Tighten to secure.
11. Raise glass shade[M] into the center of main body[L]. Slip glass shade over socket[P] and
threads[Q], and fully seat glass shade into the main body.
12. While holding the glass shade in place, slip the large flat washer[O], then the glass shade retaining
ring[N] over the socket[P] and up to the threads[Q]. Tighten the shade retaining ring to the
threads to secure large flat washer and glass shade to main body. DO NOT OVER-TIGHTEN.
13. Insert recommended bulb. (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND