FEATURES
Vehicle Fire System Control Panel
Expandable, modular
Programmable Time Delay
Multiple system discharge capability
Battery Backup Module
Alarm Silence Switch
LED annunciation of alarm, trouble, fire, operation
Low Maintenance
12V or 24V electrical systems
FM approved, including heavy-duty off-road vehicle
approvals
DESCRIPTION
The Kidde
®
KVS detection system uses a fast response,
infrared fire sensor, spot heat detection and/or Linear
Heat Sensing Cable, all of which continually monitor the
hazard area for a fire condition. Once a fire is detected, a
signal is immediately sent to the control panel located in
the operator’s area where a “FIRE” lamp is illuminated
and an audible alarm is sounded. The control unit sup-
plies engine shutdown and extinguisher discharge timing
and activation. The dry chemical and/or foam system dis-
charges suppressant routed through distribution hoses to
nozzles located in the engine compartment, hydraulic
network and other identified potential fire areas. The
vehicle engine can be automatically shutdown to maxi-
mize effectiveness of the suppressant and to prevent re-
ignition of the fire.
The Kidde KVS Automatic Fire Sensing and Suppression
Systen is designed to detect and automatically suppress
vehicle fires. The system responds to fires fueled by: die-
sel, gasoline, hydraulic fluid, and other fuels, including
hydrogen.
Areas where fires can occur include:
Engine Compartment:
Fuel Tanks and Lines
Hydraulic Reservoirs
Lines and Accumulators
•Heaters
Transmissions
Battery Compartment
Electrical Distribution and Raceways
TECHNICAL DATA
Power Requirement: 12 Vdc or 24 Vdc (9 to 32 Vdc)
Quiescent (Fire Only): 2.4 W
Extinguisher Valve Drive Requires 15 A for 30 ms
Temperature Rating: -40ºF (-40ºC) to 158ºF (70ºC)
Automatic Interface
Normally-Open 3 Amp Contact Shorts to Ground
when in Alarm
Engine Shutdown
Fuel Pump and/or Fuel Valve Shutdown
Fan Shutdown
Delay System/Engine-Shutdown Button (15 sec.
delay per activation)
Alarm Silence, Reset, Indicator Test Button
Manual Discharge Input

Summary of content (2 pages)