0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM SIGNALING UL LISTED Smoke Alarm User’s Guide Model: i9070 • 9 Volt Battery Operated ATTENTION: Please take a few minutes to thoroughly read this user’s guide which should be saved for future reference and passed on to any subsequent owner. Manual P/N 820-1494 Rev.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM What to do When the Alarm Sounds! Smoke Alarm Procedure NEVER IGNORE THE SOUND OF THE ALARM! Smoke alarms are designed to minimize false alarms. Cigarette smoke will not normally set off the alarm, unless the smoke is blown directly into the alarm. Combustion particles from cooking may set off the alarm if it is located too close to the cooking area. Large quantities of combustion particles are generated from spills or when broiling.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM Welcome 9 Volt Front-loading Battery Operated Smoke Alarm with HUSH®Control to temporarily silence nuisance alarms. Thank you for purchasing this smoke alarm. It is an important part of your family’s home safety plan. You can trust this product to provide the highest quality safety protection. We know you expect nothing less when the lives of your family are at stake.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM Product Specifications This alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioactive material (see section 9). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from any regulatory requirements. Do not try to repair the smoke alarm yourself.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 1. Recommended Locations for Smoke Alarms • Locate the first alarm in the immediate area of the sleeping rooms. Try to monitor the exit path as the sleeping rooms are usually farthest from the exit. If more than one sleeping area exists, locate additional alarms in each sleeping area (See figure 3). • Locate additional alarms to monitor any stairway as stairways act like chimneys for smoke and heat.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 1. Recommended Locations for Smoke Alarms • Put smoke alarms at both ends of a hallway or large room if the hallway or room is more than 30 ft (9.1 m) long. For large rooms, one smoke alarm is recommended for every 500 square feet of floor space. • In homes that are not well insulated, extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 2. Locations To Avoid • In the garage. Products of combustion are present when you start your automobile. • Less than 4” (10cm) from the peak of an “A” frame type ceiling. • In an area where the temperature may fall below 40ºF or rise above 100ºF, such as garages and unfinished attics; this should also include electrical boxes exposed to these environments. • In dusty areas. Dust particles may cause nuisance alarm or failure to alarm.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 3. Installation Instructions A A Alignment Marks FIGURE 5 FIGURA 5A FIGURE 6 When mounting in a hallway, the “A” line should be parallel with the hallway. 3. Make sure that the mounting screws are positioned in the small ends of the keyholes before tightening the screws. 4.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 3. Installation Instructions To activate the battery carrier tamper resist feature, remove the unit from the trim plate and locate the small cut-out in the middle of the product label on the back of the unit. With a small screwdriver, or similar tool, slide the switch towards the top of the label. (see Figure 8). The tamper resist feature is now active and the battery carrier can not be opened until the tamper resist feature is deactivated.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 4. Operation and Testing Pushing the test button on the alarm will end the Hush® period. NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH® CONTROL FEATURE AND SOUND A CONTINUOUS ALARM. CAUTION: BEFORE USING THE ALARM HUSH® FEATURE, IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS. LED INDICATOR: This smoke alarm is equipped with a red LED indicator with two modes of operation.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 5. Nuisance Alarms If the alarm does sound, check for fires first. If a fire is discovered, get out and call the fire department. If no fire is present, check to see if one of the reasons listed in Section 2 may have caused the alarm. 6.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 6. Maintenance USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR SMOKE ALARM REPLACEMENT. Note: Replacement batteries are available where you purchased your alarm.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 7. Limitations of Smoke Alarms WARNING: PLEASE READ CAREFULLY AND THOROUGHLY • NFPA 72 states: Fire-warning equipment for residential occupancies are capable of protecting about half of the occupants in potentially fatal fires. Victims are often intimate with the fire, too old or too young, or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 8. Good Safety Habits DEVELOP AND PRACTICE A PLAN OF ESCAPE • Make a floor plan indicating all doors and windows and at least two (2) escape routes from each room. Second story windows may need a rope or chain ladder. • Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire. • Determine a place outside your home where you all can meet if a fire occurs.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 10. NFPA Required Protection The National Fire Protection Association’s Standard 72 provides the following information: Smoke Detection - Where required by applicable laws, codes, or standards for a specific type of occupancy, approved single- and multiple-station smoke alarms shall be installed as follows: (1) In all sleeping rooms and guest rooms (2) Outside of each separate dwelling unit sleeping area, within 6.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 3:25 PM 12. Service and Warranty If after reviewing this manual you feel that your smoke alarm is defective in any way, do not tamper with the unit. Return for servicing to: KIDDE Safety, 1016 Corporate Park Dr., Mebane, NC 27302.
0970-7205-00(820-1494B)_En.qxd:_ 2011.1.5 QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1-800-880-6788 or contact us at our website at www.kidde.