2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM User’s Guide for Model KN-COPE-D Combination Photoelectric Smoke and Carbon Monoxide Alarm • Battery Operation: 9V Battery • 2-LED Display • Front Load Battery • Peak Level Memory • Hush ® • Voice Message System • Low Battery Hush® For questions concerning your Smoke and Carbon Monoxide Alarm, please call our Consumer Hotline at 1-800-880-6788. For your convenience, write down the following information.
540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM What To Do When The Alarm Sounds! ! WARNING: Actuation of your CO Alarm indicates the presence of Carbon Monoxide (CO) which can kill you. When the carbon monoxide alarm sounds: If alarm signal sounds: 1) Operate the test/reset button PHONE NUMBER 2) Call your emergency services (Fire Dept. or 911) 3) Immediately move to fresh air - outdoors or by an open door/window. Do a head count to check that all persons are accounted for.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM What To Do When The Alarm Sounds! NEVER IGNORE THE SOUND OF THE ALARM! Determining what type of alarm has sounded is easy with your Kidde Combination Smoke/CO Alarm. The voice message warning system will inform you of the type of situation occurring. Refer to the Features section on page 4 for a detailed description of each alarm pattern. When the smoke alarm sounds: Smoke alarms are designed to minimize false alarms.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM What To Do When The Alarm Sounds! • Go to your predetermined meeting place. When two people have arrived one should leave to call 911 from a neighbor’s home, and the other should stay to perform a head count. • Do not reenter under any circumstance until fire officials give the go ahead. • There are situations where a smoke alarm may not be effective to protect against fire as noted by the NFPA and UL. For instance: - Smoking in bed.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating/Installation Instructions Step 1: Installation Guide: A. Recommended Installation Locations . . . . . . B. Where Not to Install . . . . . . . . . . . . . . . . . . . Step 2: Mounting Instructions .
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Introduction Thank you for purchasing the Kidde Combination Photoelectric Smoke and Carbon Monoxide Alarm model KN-COPE-D. Please take a few minutes to thoroughly read this user’s guide which should be saved for future reference. Teach children how to respond to the alarms, and they should never play with the unit. Your Kidde Smoke/CO Alarm was designed to detect both smoke and carbon monoxide from any source of combustion in a residential environment.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Features • Permanent independent smoke and carbon monoxide sensors. • Smoke alarm takes precedence when both smoke and carbon monoxide are present. • Alarm/Voice message warning system that alerts you of the following conditions in the manner described below, thus eliminating any confusion over which alarm is sounding: o FIRE: The alarm/voice pattern is three long alarm beeps followed by the verbal warning message “FIRE! FIRE!”.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Features • After ten (10) years of cumulative power up, this unit will “chirp” every 30 seconds. This is an "operational end of life" feature which will indicate that it is time to replace the alarm. • Loud 85 decibel alarm • HUSH Control Feature that silences the unit during nuisance alarm situations (see page 16).
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Smoke Alarm Features Smoke Alarm The smoke alarm monitors the air for products of combustion that are produced when something is burning or smoldering. When smoke particles in the smoke sensor reach a specified concentration, the alarm/voice message warning system will sound, and be accompanied by the flashing red LED light. The smoke alarm takes precedence when both smoke and carbon monoxide are present.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Smoke Alarm Features • If the alarm is located outside the bedroom or on a different floor, it may not wake up a sound sleeper. • The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, a smoke alarm should be installed in each sleeping area on every level of a home. • Although smoke alarms can help save lives by providing an early warning of a fire, they are not a substitute for an insurance policy.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating and Installation Instructions Step 1 Installation Guide: IMPORTANT: THIS ALARM MUST BE MOUNTED ON A CEILING OR WALL. IT WAS NOT DESIGNED FOR USE AS A TABLETOP DEVICE! INSTALL ONLY AS DETAILED! A. Recommended Installation Locations: Kidde recommends the installation of a Smoke/CO Alarm in the following locations.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating and Installation Instructions Sloped Ceiling Installation: The following information is from the National Fire Protection Association and is listed in Fire Code 72. Install Smoke Alarms on sloped, peaked or cathedral ceilings at, or within 3 ft (0.9m) of the highest point (measured horizontally). NFPA 72 states “Smoke alarms in rooms with ceiling slopes greater than 1 ft to 8 ft (.3 m-2.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating and Installation Instructions ! WARNING - This product is intended for use in ordinary indoor locations of family living units. It is not designed to measure compliance with Occupational Safety and Health Administration (OSHA) commercial or industrial standards. B. Where Not to Install: Do not install in garages, kitchens, furnace rooms or bathrooms! INSTALL AT LEAST 5 FEET AWAY FROM ANY FUEL BURNING APPLIANCE. Do not install within 3 ft (.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating and Installation Instructions Step 2: Mounting Instructions CAUTION: YOUR SMOKE/CO ALARM IS SEALED AND THE COVER IS NOT REMOVABLE! 1. To help identify the date to replace the unit, a label has been affixed to the side of the alarm. Write the “Replace by” date (10 years from initial power up) in permanent marker on the label. See Alarm Replacement section for additional information. 2.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating and Installation Instructions electronics, resets the CO alarm, activates the HUSH feature, and activates the Peak Level Memory Feature. After installation, TEST THE UNIT’S ELECTRONICS by pressing and releasing the test/reset button. A series of beeps will sound, followed by the message “Fire! Fire!” then another two series of beeps and the message “WARNING! CARBON MONOXIDE!” followed by 4 additional short beeps.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating Instructions NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH® CONTROL FEATURE AND SOUND A CONTINUOUS ALARM. CAUTION: BEFORE USING THE ALARM HUSH® FEATURE, IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS. Reset Feature If the Smoke/CO Alarm is sounding a CO alarm, pressing the test/reset button will initiate a test/reset. If the CO condition that caused the alert continues, the alarm will reactivate.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating Instructions LED Indicator Operation Red LED The red LED will flash in conjunction with the alarm sounder. Therefore, the red LED will flash during a smoke alarm, a CO alarm, a low battery mode chirp and a unit error mode chirp. Green LED The green LED will flash as described below under the following conditions: – Standby Condition: The LED will flash every 30 seconds.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating Instructions POSTS FIGURE 5A FIGURE 5B This alarm also has a battery carrier tamper resist feature, which helps prevent the battery carrier from being opened. This feature is effective in preventing the removal of the battery from this device (which will render the unit inoperable during the loss of AC power).
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Operating Instructions NOTE: Before activating the battery carrier tamper resist feature, make sure a fresh battery is installed in the unit and that the battery carrier is properly closed. If the battery carrier tamper resist feature is activated while the battery carrier is open, the battery carrier will not close and the unit will be inoperable during the loss of AC power.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Battery Replacement If any form of battery failure is detected the red LED light will flash and the unit will “chirp” one time, followed by the warning message “LOW BATTERY”. This cycle will occur once every minute for the first hour. After the first hour, the red LED light will continue flashing accompanied by the chirp only sound every 60 seconds.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM General Maintenance Alarm ReplacementAlarm Replacement Ten years after initial power-up, this unit will “chirp” twice every 30 seconds to indicate that it is time to replace the alarm. A label has been provided on the side of the alarm that has “Replace by” printed on it. Write the replace by date on the label. The date written on the label should be ten (10) years after the alarm was initially powered.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM General Maintenance attempt to disassemble the unit or clean inside. This action will void your warranty. Move the Smoke/CO Alarm and place in another location prior to performing any of the following: • Staining or stripping wood floors or furniture • Painting • Wall papering • Using adhesives Storing the unit in a plastic bag during any of the above projects will protect the sensors from damage. Do not place near a diaper pail.
40-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Carbon Monoxide Safety Information General CO Information Carbon Monoxide (CO) is a colorless, odorless, and tasteless poison gas that can be fatal when inhaled. CO inhibits the blood’s capacity to carry oxygen. Possible Sources CO can be produced when burning any fossil fuel: gasoline, propane, natural gas, oil and wood. It can be produced by any fuel-burning appliance that is malfunctioning, improperly installed, or not ventilated correctly.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Carbon Monoxide Safety Information CO Safety Tips Every year have the heating system, vents, chimney and flue inspected and cleaned by a qualified technician. Always install appliances according to manufacturer’s instructions and adhere to local building codes. Most appliances should be installed by professionals and inspected after installation.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Fire Safety Information poisoning indicate that while victims are aware they are not well, they become so disoriented they are unable to save themselves by either exiting the building, or calling for assistance. Also, young children and household pets may be the first effected. Familiarization with the effects of each level is important. Escape Plan Prepare and practice a home escape plan twice a year, including drills at night.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Industry Safety Standards NFPA (National Fire Protection Association) For your information, the National Fire Protection Association’s Standard 72, reads as follows: Smoke Detection.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Industry Safety Standards Consumer Product Safety Commission The Consumer Product Safety Commission (CPSC) recommends the use of at least one CO Alarm per household, located near the sleeping area. FCC COMPLIANCE STATEMENT Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Warranty and Service Information TEN YEAR LIMITED WARRANTY Kidde warrants that the enclosed alarm (but not the battery) will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of purchase.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM Warranty and Service Information This alarm is not intended to alert hearing impaired individuals. Service Information During the specified warranty period Kidde will repair or replace, at its discretion any defective Kidde Combination Smoke & CO Alarms that are returned in a postage paid package to the following address: Kidde, Attn: Warranty Returns, 1016 Corporate Park Drive, Mebane, NC 27302, USA.
2540-7202-00(KN-COPE-D).qxd:_ 2012.9.25 10:43 AM QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1-800-880-6788 or contact us at our website at www.kidde.com Kidde, 1016 Corporate Park Drive, Mebane, NC 27302 Made in China U.S.