210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM User Guide for Model i12010S Ionization Smoke Alarm • 120V AC • Sealed 3V Lithium Battery Backup • 2-LED Display • Test/Hush® button 10 YEAR SMOKE ALARM GREENSTANDBY For questions concerning your Smoke Alarm, please call our Product Support Line at 1-800-880-6788. For your convenience, write down the following information.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 Product View . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 4-6 Installation Instructions Step 1: Installation Instructions: A. Recommended Installation Locations . . Pages 7 B. Where Not to Install . . . . . . . . . . . . . . . Page 8 Step 2: Wiring Instructions . . .
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Introduction Thank you for purchasing the Kidde Smoke Alarm model # i12010S. This alarm is suitable as a Single Station and/or Multiple Station (24 devices) alarm. This alarm has a ten-year limited warranty. Please take a few minutes to thoroughly read this user guide, and save for future reference. Teach children how to respond to the alarms, and that they should never play with the unit.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Features • Loud 85 decibel alarm. • Ionization smoke sensor. • Powered by 120V AC (60 Hz, 45mA max) wire-in connector . • Interconnectable to other Kidde/Nighthawk brand smoke and CO alarms (see page 15 for details). SMOKE ALARM: The alarm pattern is three long alarm beeps, which will repeat until the smoke is eliminated. The red LED light will flash with the alarm beeps..
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Features and General Information NFPA 72 states: Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape, followed by the appropriate egress actions by those occupants. Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Installation Instructions Step 1 Installation Guide: IMPORTANT: THIS ALARM MUST BE MOUNTED ON A CEILING OR WALL. IT WAS NOT DESIGNED FOR USE AS A TABLETOP DEVICE! INSTALL ONLY AS DETAILED! A. Recommended Installation Locations: Kidde Safety recommends the installation of a Smoke Alarm in the following locations.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Installation Instructions Sloped Ceiling Installation: The following information is from the National Fire Protection Association and is listed in Fire Code 72. Install Smoke Alarms on sloped, peaked or cathedral ceilings at, or within 3 ft (0.9m) of the highest point (measured horizontally). NFPA 72 states “Smoke alarms in rooms with ceiling slopes greater than 1 ft to 8 ft (.3 m-2.4 m) horizontally shall be located on the high side of the room”.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Installation Instructions through poorly insulated walls and roof. This may cause a thermal barrier, which can prevent smoke from reaching an alarm mounted on the ceiling. In such mobile homes install your Smoke Alarm on an inside wall with the top edge of the alarm at a minimum of 4 inches (10cm) and a maximum of 12 inches (30.5cm) below the ceiling (see figure 2).
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Installation Instructions electronic noise may cause nuisance alarms. Do not place in direct sunlight and keep out of insect infested areas. Extreme temperatures will effect the sensitivity of the Smoke Alarm. Do not install in areas where the temperature is colder than 40 degrees Fahrenheit (4.4˚ Celsius) or hotter than 100 degrees Fahrenheit (37.8˚ Celsius), such as garages and unfinished attics.
10-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Installation Instructions • For alarms that are used as single station, DO NOT CONNECT THE RED WIRE TO ANYTHING. Leave the red wire insulating cap in place to make certain that the red wire cannot contact any metal parts or the electrical box. • When alarms are interconnected, all interconnected units must be powered from a single circuit. • A maximum of 24 Kidde Safety devices may be interconnected in a multiple station arrangement.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Installation Instructions Step 3 Mounting Instructions: ! CAUTION: YOUR SMOKE ALARM IS SEALED AND THE COVER IS NOT REMOVABLE! 1. To help identify the date to replace the unit, write the "Replace by" date (10 years from initial power up) in permanent marker in the space provided on the side of the alarm. See Alarm Replacement section for additional information. 2.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Installation Instructions Step 4 Testing the Alarm ! CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms length away from the unit when testing. After installation, TEST THE UNIT’S ELECTRONICS by pressing and releasing the test/reset button. You will hear one beep on the button push, and will then hear the following sequence of "beeps: Three long beeps. Pause Three long beeps.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Operating Instructions • For more information about compatible interconnect units and their functionality in an interconnect system, visit our web site at www.kidde.com. Smoke HUSH Control Feature The HUSH feature has the capability of temporarily desensitizing the smoke alarm circuit for approximately 9 minutes. This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the alarm.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Operating Instructions -Green LED The green LED will flash as described below under the following conditions: – Standby Condition (powered by AC and battery backup): The LED will be constantly on. – Standby Condition (powered by only battery backup): The LED will flash every 60 seconds. – Smoke Alarm Memory Condition: The LED will flash every second during alarm.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Operating Instructions Tamper Resist Feature To make your smoke alarm tamper resistant, a tamper resist feature has been provided. Activate the tamper resist feature by breaking off the four posts in the square holes in the trim ring (see figure 5A). When the posts are broken off, the tamper resist tab on the base is allowed to engage the mounting bracket.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM What To Do If The Alarm Sounds NEVER IGNORE THE SOUND OF THE ALARM! When the smoke alarm sounds: Smoke alarms are designed to minimize false alarms. Cigarette smoke will not normally set off the alarm, unless the smoke is blown directly into the alarm. Combustion particles from cooking may set off the alarm if located too close to the cooking area. Large quantities of combustible particles are generated from spills or when broiling.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Battery Information Alarm Removal IF TAMPER RESIST FEATURE HAS BEEN ACTIVATED, REFER TO TAMPER RESIST FEATURE DESCRIPTION ON PAGE 17 FOR REMOVAL INSTRUCTIONS. Remove the alarm from the mounting bracket by rotating the alarm in the direction of the “OFF” arrow on the cover. Battery (Non-Replaceable) This alarm contains a sealed 3V Lithium battery, which will last the life of the alarm.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM DEACTIVATION OF ALARM ! WARNING: a. When disposing of the alarm, the alarm must be deactivated which discharges the battery to a safe level for disposal. b. Deactivation of the alarm is permanent. Once the alarm has been deactivated, it cannot be reactivated! c. Once deactivated, the alarm will NO LONGER DETECT SMOKE . d. Once the alarm is deactivated the battery will be depleted and the alarm will no longer function. e.
otating cover rp” ng 1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM General Maintenance To keep your Smoke Alarm in good working order, please follow these simple steps: • Verify the unit's alarm and LED lights operation by pushing the test/reset button once a week. • Remove the unit from mounting bracket and vacuum the alarm cover and vents with a soft brush attachment once a month to remove dust and dirt.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Fire Safety Information Escape Plan Familiarize everyone with the sound of the smoke alarm and train them to leave the home when they hear it. Practice a fire drill at least every six months, including fire drills at night. Ensure that small children hear the alarm and wake when it sounds. They must wake up in order to execute the escape plan. Practice allows all occupants to test your plan before an emergency. You may not be able to reach your children.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Industry Safety Standards NFPA (National Fire Protection Association) For your information, the National Fire Protection Association’s Standard 72, reads as follows: Smoke Detection. Where required by applicable laws, codes, or standards for the specified occupancy, approved single- and multiple-station smoke alarms shall be installed as follows: (1) In all sleeping rooms.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Industry Safety Standards NRC Ionization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products. The radioactive element is safely contained in the chamber and requires no adjustments or maintenance. This smoke alarm meets or exceeds all government standards. It is manufactured and distributed under license from the U.S. Nuclear Regulatory Commission.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Limited Warranty and Service Information Limited Warranty TEN YEAR LIMITED WARRANTY KIDDE warrants that the enclosed alarm will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of purchase.
1210-7201-01(i12010S)_V3.qxd:_ 2014.2.20 3:19 PM Limited Warranty and Service Information Your Kidde Smoke Alarm is not a substitute for property, fire, disability, life or other insurance of any kind. Appropriate insurance coverage is your responsibility. Consult your insurance agent. Removal of the front cover will void the warranty. This alarm is not intended to alert hearing impaired individuals.