Use and Care Manual
recommend specific locations for smoke alarms, such as every level and
sleeping area of the dwelling. They also recommend a CO alarm be installed
on each level of the home—ideally on any level with fuel-burning appliances
and outside of sleeping areas. The alarm can be installed on the surface
of any wall or ceiling following the UL/NFPA/Manufacturer’s recommended
placement guidelines. See User Guide for more location information and
additional instructions.
Architectural & Engineering Specifications
WARNING: This product is intended for use in indoor residential locations. It is not
designed to measure compliance with Occupational Safety and Health Administration
(OSHA) commercial or industrial standards.
This device is designed to help protect individuals from acute eects of
Carbon Monoxide exposure. It will not fully safeguard individuals with
specific medical conditions. If in doubt, consult a medical practitioner.
Individuals with medical problems may consider using warning devices
which provide audible and visual signals for carbon monoxide concentrations
under 30 ppm.
CO alarm response times:
70 ppm: 60-240min
150 ppm: 10-50min
400 ppm: 4-15min
The alarm shall include a test button that will electronically simulate the
presence of smoke and CO and cause the unit to go into both modes of
alarm. This sequence tests the unit’s electronics to ensure proper operation.
The unit shall incorporate three LED colors. A green LED will flash every
60 seconds when in standby condition. An amber LED will indicate fault
conditions. A red LED will flash in sync with the smoke alarm pattern, and will
also indicate alarm memory.
The unit shall include the Hush™ feature that silences a smoke alarm
for approximately 8-10 minutes if a nuisance alarm condition occurs. The
red LED on the alarm will flash every 2 seconds while in Hush and will
automatically reset itself.
At the date of manufacture, the unit shall at a minimum meet the
requirements of UL 217, UL 2034, NFPA 72, NFPA 101 (One and two family
dwellings), Federal Housing Authority (FHA), and Housing and Urban
Development (HUD).
Technical Specifications
Model: 30CUD10
Power Source: 10-year† sealed battery operated
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C)
Humidity Range: 10 to 95% relative humidity (RH), non-condensing
Size: 5” W x 2” D x 5” H
Weight: 0.79 lb
Wiring: N/A
Interconnects: N/A
Warranty: 10-Year Limited Warranty (battery included)
Replacement Batteries: N/A
Ordering Information
Ordering
Number UPC GTIN Pack Config. Pack Qty
Case Dimensions
(D x W x H inches) Case Weight (lbs) Cartons/Pallet
21031514 047871315147 – Box – – – –
21031516 047871315161 – Box – – – –
21031517 047871315178 – Box – – – –
21032839 047871328390 – Box – – – –
21032840 047871328406 – Box – – – –