Use and Care Manual
8
5. Introduction, Product Features and Specifications
Introduction
This alarm detects products of combustion using photoelectric technology. Ten (10) years after the unit was activat-
ed, this unit will automatically alert you that it is time to replace the unit. This is called “End of Unit Life” mode. See
Troubleshooting Guide. To help identify the date to replace the unit, a label has been affixed to the side of the alarm.
Write the “Install date” in the space provided, and then write in the “Replace by” date (10 years from initial power up) in
permanent marker on the label prior to installing the unit. NOTE: AC power must be connected to obtain the full 10
year battery and unit life.
Product Features and Specifications:
• Temperature: Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
• Humidity: Operating range: up to 95% RH non-condensing
• Audible Alarm: 85+ dB at 10’ 3.0 to 3.5 KHz pulsing alarm, with voice message “Fire!”
• Smoke Sensor: Photoelectric
• Voice message system
• Smoke Alarm HUSH
TM
Control
• Ambient Light Sensing
• Powered by 120VAC (60 Hz, 53 mA max) wire-in connector with sealed lithium battery backup
• Hardwire Interconnect
• Wi-Fi Compatible to Mobile Device ( Requires 802.11b/g/n (2.4GHz) Wi-Fi ). NOTE: Wi-Fi features do not
function without AC power.
• One large, user-friendly button