LED Indicator Operation
Red LED
The red LED will flash as described below under the following
conditions:
--During smoke or CO alarm, with every beep
--During testing (same as alarm)
--Low battery, single flash with chirp
--End of product life, double flash every 30 seconds with chirp
--Unit error mode, single flash with chirp
--Unit error mode, a Fault Code is flashed every 30 seconds (can
be observed and reported to customer service for
troubleshooting).
Green LED
The green LED will flash as described below under the following
conditions:
– Standby Condition :
The LED will flash every 60 seconds..
– Alarm Memory Condition: The LED will flash every
second during alarm. When the alarm condition goes
away, the originating alarm unit will flash the LED every
16 seconds until the test/reset button is pressed, thus
resetting the alarm.
– HUSH MODE Condition: The LED will flash every 2
seconds while the alarm is in HUSH mode.
Tamper Resist Feature
To make your smoke/CO alarm tamper resistant, a tamper resist
feature has been provided. Activate the tamper resist feature by
breaking off the four posts in the square holes in the trim ring
(see figure 5A). When the posts are broken off, the tamper resist
tab on the base is allowed to engage the mounting bracket.
Rotate the alarm onto the mounting bracket until you hear the
tamper resist tab snap into place, locking the alarm on the
mounting bracket. Using the tamper resist feature will help deter
children and others from removing the alarm from bracket.
NOTE: To remove the alarm when the tamper resist tab is
engaged, press down on the tamper resist tab, and rotate the
alarm off of the bracket (see figure 5B).