2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM User Guide for Model KN-COSM-BA Combination Smoke and Carbon Monoxide Alarm • • • • • 2 AA Battery Powered 2-LED Display Peak Level Memory Test/Hush® button Voice Message System For questions concerning your Smoke and Carbon Monoxide Alarm, please call our Product Support Line at 1-800-880-6788. For your convenience, write down the following information.
553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 Product View . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 4-7 Installation Instructions Step 1: Installation Instructions: A. Recommended Installation Locations . . Pages 8-10 B. Where Not to Install . . . . . . . . . . . . . . . Page 10 Step 2: Mounting Instructions.. . .
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Introduction Thank you for purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm model # KN-COSM-BA. This alarm is suitable as a Single Station. This alarm has a ten-year limited warranty. Please take a few minutes to thoroughly read this user guide, and save for future reference. Teach children how to respond to the alarms, and that they should never play with the unit.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Features • Loud 85 decibel alarm. • Permanent independent smoke and carbon monoxide sensors. • Smoke alarm takes precedence when both smoke and carbon monoxide are present. • Powered by two AA batteries.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Features – Only if button is pushed System announces “CARBON MONOXIDE PREVIOUSLY DETECTED” when the unit has detected CO concentrations of 100 ppm or higher. – System announces “PUSH TEST BUTTON” when the unit is powered up, reminding user to activate the Test Button. • End of Life Hush. At end of product life, the button can be pushed to silence the end of life "chirp" for approximately 3 days at a time, for a maximum of 30 days life extension.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Features and General Information Smoke Alarm The smoke alarm monitors the air for products of combustion that are produced when something is burning or smoldering. When smoke particles in the smoke sensor reach a specified concentration, the alarm/voice message warning system will sound, and be accompanied by the flashing red LED light. The smoke alarm takes precedence when both smoke and carbon monoxide are present.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Features and General Information • If the alarm is located outside the bedroom or on a different floor, it may not wake up a sound sleeper. • The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, a smoke alarm should be installed in each sleeping area on every level of a home.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Installation Instructions Step 1 Installation Guide: IMPORTANT: THIS ALARM MUST BE MOUNTED ON A CEILING OR WALL. IT WAS NOT DESIGNED FOR USE AS A TABLETOP DEVICE! INSTALL ONLY AS DETAILED! A. Recommended Installation Locations: Kidde Safety recommends the installation of a Smoke/CO Alarm in the following locations.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Installation Instructions Sloped Ceiling Installation: The following information is from the National Fire Protection Association and is listed in Fire Code 72. Install Smoke Alarms on sloped, peaked or cathedral ceilings at, or within 3 ft (0.9m) of the highest point (measured horizontally). NFPA 72 states “Smoke alarms in rooms with ceiling slopes greater than 1 ft to 8 ft (.3 m-2.4 m) horizontally shall be located on the high side of the room”.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Installation Instructions THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION’S STANDARD 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). WARNING - This product is intended for ! use in ordinary indoor locations of family living units. It is not designed to measure compliance with Occupational Safety and Health Administration (OSHA) commercial or industrial standards. B.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Installation Instructions Step 2 Mounting Instructions: ! CAUTION: YOUR SMOKE/CO ALARM IS SEALED AND THE COVER IS NOT REMOVABLE! 1. To help identify the date to replace the unit, write the "Replace by" date (10 years from initial power up) in permanent marker in the space provided on the side of the alarm. See Alarm Replacement section for additional information. 2.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Installation Instructions Step 3 Testing the Alarm ! CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms length away from the unit when testing. After installation, TEST THE UNIT’S ELECTRONICS by pressing and releasing the test/reset button. You will then hear the following sequence of "beeps" and verbal warnings: Three long beeps. Verbal warning: "FIRE!" Three long beeps. Four quick beeps.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Operating Instructions Smoke HUSH Control Feature The HUSH feature has the capability of temporarily desensitizing the smoke alarm circuit for approximately 9 minutes. This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the alarm. You can put your Smoke/CO Alarm in HUSH mode by pushing the test/reset button.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Operating Instructions A A Posts FIGURE 5A FIGURE 5B NEVER IGNORE THE SOUND OF THE ALARM! Determining what type of alarm has sounded is easy with your Combination Smoke/CO Alarm. The voice message warning system will inform you of the type of situation occurring. Refer to the Features section on pages 4-7 for a detailed description of each alarm pattern.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM What To Do If The Alarm Sounds If the alarm sounds, check for fires first. If a fire is discovered follow these steps. Become thoroughly familiar with these items, and review with all family members! • Alert small children in the home. • Leave immediately using one of your planned escape routes (see page 26). Every second counts, don’t stop to get dressed or pick up valuables.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM What To Do If The Alarm Sounds When the carbon monoxide alarm sounds: ! WARNING - Actuation of your CO Alarm indicates the presence of Carbon Monoxide (CO) which can kill you. If alarm signal sounds: 1) Operate the test/reset button PHONE NUMBER 2) Call your emergency services (Fire Dept. or 911) 3) Immediately move to fresh air - outdoors or by an open door/window. Do a head count to check that all persons are accounted for.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Battery Replacement Alarm Removal IF TAMPER RESIST FEATURE HAS BEEN ACTIVATED, REFER TO TAMPER RESIST FEATURE DESCRIPTION ON PAGE 17 FOR REMOVAL INSTRUCTIONS. Remove the alarm from the mounting bracket by rotating the alarm in the direction of the “OFF” arrow on the cover. Battery Replacement If any form of battery failure is detected the red LED light will flash and the unit will "chirp" once every 60 seconds for at least 7 days.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Battery Replacement Replace batteries with one of the following approved brands: Duracell MN1500, MX1500, Energizer E91, Gold Peak 15A or Golden Power GLR6A . These batteries can be purchased at your local retailer. ! WARNING! Use only the batteries specified. Use of different batteries may have a detrimental effect on the Smoke/CO alarm. A good safety measure is to replace the batteries twice a year, at the same time.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM General Maintenance To keep your Smoke/CO Alarm in good working order, please follow these simple steps: • Verify the unit's alarm and LED lights operation by pushing the test/reset button once a week. • Remove the unit from mounting bracket and vacuum the alarm cover and vents with a soft brush attachment once a month to remove dust and dirt.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM General Maintenance Carbon Monoxide Safety Information General CO Information Carbon monoxide (CO) is a colorless, odorless, and tasteless poison gas that can be fatal when inhaled. CO inhibits the blood’s capacity to carry oxygen. Possible Sources CO can be produced when burning any fossil fuel: gasoline, propane, natural gas, oil and wood.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM General Maintenance CO Safety Tips Every year have the heating system, vents, chimney and flue inspected and cleaned by a qualified technician. Always install appliances according to manufacturer’s instructions and adhere to local building codes. Most appliances should be installed by professionals and inspected after installation.
53-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM General Maintenance become so disoriented they are unable to save themselves by either exiting the building, or calling for assistance. Also, young children and household pets may be the first effected. Familiarization with the effects of each level is important. Fire Safety Information Escape Plan Familiarize everyone with the sound of the smoke alarm and train them to leave the home when they hear it.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM General Maintenance Industry Safety Standards NFPA (National Fire Protection Association) For your information, the National Fire Protection Association’s Standard 72, reads as follows: Smoke Detection.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Carbon Monoxide Safety Information Consumer Product Safety Commission The Consumer Product Safety Commission (CPSC) recommends the use of at least one CO Alarm per household, located near the sleeping area. NRC Ionization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Carbon Monoxide Safety Information Limited Warranty TEN YEAR LIMITED WARRANTY KIDDE warrants that the enclosed alarm (but not the battery) will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of purchase.
2553-7201-00(KN-COSM-BA)_V5.qxd:_ 2013.9.13 10:39 AM Fire Safety Information Your Kidde Combination Smoke & CO Alarm is not a substitute for property, fire, disability, life or other insurance of any kind. Appropriate insurance coverage is your responsibility. Consult your insurance agent. Removal of the front cover will void the warranty. This alarm is not intended to alert hearing impaired individuals.