SIGNALING UL LISTED Smoke Alarm User’s Guide Model: i9030, i9040, i9040RV i9050, i9060, i9060RV and i9080 i9040 and i9040RV i9030 i9060 and i9060RV i9050 i9080 • 9 Volt Battery Operated ATTENTION: Please take a few minutes to thoroughly read this user’s guide which should be saved for future reference and passed on to any subsequent owner. Manual P/N 820-1493 Rev.
What to do When the Alarm Sounds! Smoke Alarm Procedure NEVER IGNORE THE SOUND OF THE ALARM! Smoke alarms are designed to minimize false alarms. Cigarette smoke will not normally set off the alarm, unless the smoke is blown directly into the alarm. Combustion particles from cooking may set off the alarm if it is located too close to the cooking area. Large quantities of combustion particles are generated from spills or when broiling.
Product Specifications This alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioactive material (see section 9). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from any regulatory requirements. Do not try to repair the smoke alarm yourself. Refer to the instructions in section 12 for service.
1. Recommended Locations for Smoke Alarms • Put smoke alarms at both ends of a hallway or large room if the hallway or room is more than 30 ft (9.1 m) long. For large rooms, one smoke alarm is recommended for every 500 square feet of floor space. • In homes that are not well insulated, extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof. This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling.
3. Installation Instructions 3. Installation Instructions MOUNTING INSTRUCTIONS CAUTION: This unit is sealed. The cover is not removable! UP F OR UP WA L L MO UN U P T IN 1. Remove the mounting plate from the back of the alarm by holding the mounting plate and twisting the alarm in the direction indicated by the “OFF” arrow on the alarm cover. G A 2.
4. Operation and Testing OPERATION: The smoke alarm is operating once a fresh battery is installed and testing is complete. When products of combustion are sensed, the unit sounds a loud 85db pulsating alarm until the air is cleared. HUSH CONTROL: The “HUSH” feature has the capability of temporarily desensitizing the alarm circuit for approximately 8 minutes. This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the alarm.
6. Maintenance USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR i9040RV AND i9060RV SMOKE ALARM BATTERY REPLACEMENT: Alkaline type: ENERGIZER 522; DURACELL MN1604, MX1604; PANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61(GA) NOTE: WEEKLY TESTING IS REQUIRED. WARNING! USE ONLY THE BATTERIES SPECIFIED. USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE ALARM.
7. Limitations of Smoke Alarms • If the alarm is located outside the sleeping room or on a different floor, it may not wake up a sound sleeper. • The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, a smoke alarm should be installed in each sleeping area on every level of a home. • Although smoke alarms can help save lives by providing an early warning of a fire, they are not a substitute for an insurance policy.
11. CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL) Ionization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products. The radioactive element is safely contained in the chamber and requires no adjustments or maintenance. This smoke alarm meets or exceeds all government standards. It is manufactured and distributed under license from the U.S. Nuclear Regulatory Commission. 12.
QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1-800-880-6788 or contact us at our website at www.kidde.