Use and Care Manual

Plug-In Carbon Monoxide Alarm
AC Powered with Sealed Lithium Battery Backup,
Digital Display, and Voice Alarm
Description
The Kidde 900-0282 AC Powered, Plug-in carbon monoxide
alarm with sealed lithium battery backup and digital display is
an easy to install unit that provides reliable protection against
the dangers of carbon monoxide. The 10-year* sealed battery
offers protection during power outages, prevents unwarranted
removal of the battery, and eliminates the need for annual
battery replacement.
The voice feature provides an audible warning to the presence
of CO that plays “Warning! Carbon Monoxide!”, when levels
reach 100 PPM that is in addition to the 85db tone signal
when in alarm mode. Voice warnings are also used to com-
municate in the event of low battery condition or previous
detection of CO.
The digital display feature adds an advanced level of protection
showing CO levels in PPM allowing you to see if levels change.
This display uses LED technology which allows the CO levels to
be visible in dark conditions and further distances than other
alarms that use less visible LCD components. The display will
automatically adjust brightness level to adapt to ambient light
conditions, which offers both a brighter display during lighted
environments and dims to provide a visible, but softer contrast
at night. The display deactivates when AC power is removed
to conserve battery life.
The Kidde 900-0282 has a 10-year operational life, which pro-
vides a 40% longer lifespan than other plug-in CO alarms. The
alarm includes a 10-year limited warranty, and is listed by UL
to the UL2034 Standard.
Features and Benefits
10 Year Sealed Battery – Provides protection during power
outages and does not need replacement during life of the alarm.
Digital Display – Displays the level of CO the unit is sensing.
LEDs provide clear daytime visibility that automatically dims in
dark conditions.
Voice Alarm – Communicates verbal warning once CO levels
reach 100 PPM.
Peak Level Button – Displays the highest level of CO recorded
since last reset. Ideal for checking previous conditions while
away or to assist medical responders.
Test/Reset Button – Tests the unit for proper operation. Resets
the Carbon Monoxide Alarm.
10-Year End of Life Warning – Alerts user to replace CO
alarm after 10 years of operation, as required by UL.
Rotating AC Blades – Unit remains vertical whether electrical
socket is in vertical or horizontal orientation.
UL Listed – Listed by UL to the UL2034 Standard..
*10-Year Limited Warranty
10
Part Number: 900-0282
Model KN-COP-DP-10YB
Sealed Lithium Battery Backup — 10-year* tamper proof battery
eliminates need for battery replacement. Alerts User to replace
alarm after 10 years of operation.
Voice Alarm Unit announces “Warning! Carbon Monoxide!”
once CO levels exceed 100 PPM, and also when in alarm condition.
Digital Display Displays the level of carbon monoxide the unit
is sensing. Automatically dims in low light conditions.
Peak Level Memory —Displays the peak CO level recorded since
its last reset.
End of Life Alarm — Alerts user to replace alarm after 10 years of
operation. Can be temporarily silenced for convenience.
No Night Chirps End of Life and low battery signals programmed
not to occur in dark conditions, helping to prevent needless waking
of user.
Ten Year Sealed Battery
Smoke & Carbon Monoxide Alarms

Summary of content (2 pages)