Brochure
1394 South Third Street, Mebane NC 27302
1-800-880-6788 • www.kiddeus.com
Distributed by:
Carbon Monoxide Alarm
Battery Operated with Digital Display
Part Number 900-0146
Model KN-COPP-B
Technical Specifications
Part Number: 900-0146
Unit Number: KN-COPP-B
UPC Number: 0-47871-00146-0
Power Source: Three AA batteries (included)
Sensor: Electrochemical
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C)
Humidity Range: up to 95% relative humidity (RH)
Size: 5.5” diameter x 1.4” depth
Weight: .66lbs (with batteries)
Interconnects: No
Wiring: No
Warranty: 5 year limited
Ordering Information
UPC: 0-47871-00146-0
Part Dimensions Case/ Layers/ Skid
Number I 2 of 5 Pack Quantity (w x d x h inches) Weight Skid Skid Weight
900-0146** N/A Individual 7.25 x 11 x 1.75 .55lbs N/A N/A N/A
900-0146-004 100 47871 00146 7 Master Pack (4 units) 11.5 x 11.75 x 7.5 2.6lbs 90 3 234lbs
900-0146-020 200 47871 00146 4 Cut Case (20 units) 16 x 20.75 x 11.75 11lbs 18 3 198lbs
900-0146-060 300 47871 00146 1 Power Tower (60 units) 20 x 24 x 41 (incl. pallet) 33lbs 3 3 99lbs
**Not for sale by individual unit
20
60
4
1
UNIT MASTER PACK CUT CASE POWER TOWER
Architectural and Engineering
Specifications
The carbon monoxide alarm shall be Kidde Unit Number KN-COPP-B
(part number 900-0146) or approved equal. It shall be powered by
three (3) AA batteries (included). The unit shall have a snap open
cover that allows immediate access to batteries. The temperature
operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and
the humidity operating range shall be 5% - 95% relative humidity.
The CO sensor shall be of a fuel cell design and shall meet the
sensitivity requirements of Underwriters Laboratories UL2034 Single
and Multiple Station Carbon Monoxide Alarms.
The alarm can be installed on the surface of any wall or ceiling
following the UL/NFPA/Manufacturer’s recommended placement
guidelines. The alarm shall include a battery lockout system that
deters closure of battery door without using three batteries.
The unit shall incorporate a digital display that meets the sensitiv-
ity requirements of UL 2034. The display will identify the levels of CO
in parts per million (ppm) once that level reaches 30ppm (i.e.:
“abnormal” levels).
The alarm shall include a test button that will electronically simu-
late the presence of CO and cause the unit to go into alarm. This
sequence tests the unit’s electronics to ensure proper operation.
Per UL 2034 requirements, the CO sensor will not alarm to levels
of CO below 30 ppm and will alarm in the following time range
when exposed to the corresponding levels of CO.
70 ppm CO Concentration 60 – 240 minutes
150 ppm CO Concentration 10 – 50 minutes
400 ppm CO Concentration 4 – 15 minutes
The unit shall incorporate 2 LED’s. A green LED will flash once
every 30 seconds to indicate the alarm is operating properly when
power is present. A red LED will pulse to to indicate carbon monoxide
has been detected until the device is reset or CO is eliminated.
The alarm shall include a piezoelectric horn that is rated at 85
decibels at 10 feet. When the unit detects carbon monoxide, the
alarm pattern will be four (4) short beeps – followed by five (5) sec-
onds of silence – followed by four (4) short beeps with a correspond-
ing red LED flash.
It shall also include a 5-year manufacturer’s limited warranty.
*Based on accuracy claims of major manufacturers
5.5" 1.4"