2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 User Guide for Model KN-COSM-IBA Combination Smoke and Carbon Monoxide Alarm • • • • • 120V AC 2 - AA Battery Backup 2-LED Display Peak Level Memory Test/Hush® button • Voice Message System • Low Battery Hush For questions concerning your Smoke and Carbon Monoxide Alarm, please call our Product Support Line at 1-800-880-6788. For your convenience, write down the following information.
544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 Product View . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 4-7 Installation Instructions Step 1: Installation Instructions: A. Recommended Installation Locations . . Pages 8-10 B. Where Not to Install . . . . . . . . . . . . . . . Page 10 Step 2: Wiring Instructions . . . .
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 2:44 PM Introduction Thank you for purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm model # KN-COSM-IBA. This alarm is suitable as a Single Station and/or Multiple Station (24 devices) alarm. This alarm has a ten-year limited warranty. Please take a few minutes to thoroughly read this user guide, and save for future reference. Teach children how to respond to the alarms, and that they should never play with the unit.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Features • Loud 85 decibel alarm. • Permanent independent smoke and carbon monoxide sensors. • Smoke alarm takes precedence when both smoke and carbon monoxide are present. • Powered by 120V AC (60 Hz, 25 mA max) wire-in connector and two AA battery backup. • Interconnectable to other Kidde/Nighthawk brand smoke and CO alarms (see page 15 for details).
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 2:44 PM Features • Voice Message System that alerts user to the following conditions: – Only for smoke alarm Hush System announces “HUSH MODE ACTIVATED” when the unit is first put into HUSH Mode. – Only for smoke alarm Hush System announces “HUSH MODE CANCELLED” when unit resumes normal operation after Hush Mode has been cancelled.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Features and General Information Smoke Alarm The smoke alarm monitors the air for products of combustion that are produced when something is burning or smoldering. When smoke particles in the smoke sensor reach a specified concentration, the alarm/voice message warning system will sound, and be accompanied by the flashing red LED light. The smoke alarm takes precedence when both smoke and carbon monoxide are present.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 2:44 PM Features and General Information • If the alarm is located outside the bedroom or on a different floor, it may not wake up a sound sleeper. • The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, a smoke alarm should be installed in each sleeping area on every level of a home.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Installation Instructions Step 1 Installation Guide: IMPORTANT: THIS ALARM MUST BE MOUNTED ON A CEILING OR WALL. IT WAS NOT DESIGNED FOR USE AS A TABLETOP DEVICE! INSTALL ONLY AS DETAILED! A. Recommended Installation Locations: Kidde Safety recommends the installation of a Smoke/CO Alarm in the following locations.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 2:44 PM Installation Instructions Sloped Ceiling Installation: The following information is from the National Fire Protection Association and is listed in Fire Code 72. Install Smoke Alarms on sloped, peaked or cathedral ceilings at, or within 3 ft (0.9m) of the highest point (measured horizontally). NFPA 72 states “Smoke alarms in rooms with ceiling slopes greater than 1 ft to 8 ft (.3 m-2.4 m) horizontally shall be located on the high side of the room”.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Installation Instructions THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION’S STANDARD 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). WARNING - This product is intended for ! use in ordinary indoor locations of family living units. It is not designed to measure compliance with Occupational Safety and Health Administration (OSHA) commercial or industrial standards. B.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Installation Instructions Step 2 Wiring Instructions: ! WIRING REQUIREMENTS • This smoke alarm should be installed on a U.L. listed or recognized junction box. All connections should be made by a qualified electrician and all wiring used shall be in accordance with articles 210 and 300.3(B) of the U.S. National Electrical Code ANSI/NFPA 70, NFPA 72 and/or any other codes having jurisdiction in your area.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Installation Instructions • A maximum of 24 Kidde Safety devices may be interconnected in a multiple station arrangement. The interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, CO, Smoke/ CO Combination, heat, etc.). This Smoke/CO combination alarm must be counted as a smoke alarm when determining the number of units on an interconnect line.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Installation Instructions Step 3 Mounting Instructions: ! CAUTION: YOUR SMOKE/CO ALARM IS SEALED AND THE COVER IS NOT REMOVABLE! 1. To help identify the date to replace the unit, write the "Replace by" date (10 years from initial power up) in permanent marker in the space provided on the side of the alarm. See Alarm Replacement section for additional information. 2.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Installation Instructions 7. Turn on the AC power. The green AC Power On Indicator should be lit when the alarm is operating from AC power. 8. Two labels are included with your alarm. They have important information on what to do in case of an alarm. Add the phone number of your emergency service provider (Fire Department or 911) in the space provided.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Operating Instructions • When mixing compatible models with battery backup with models without battery backup, be advised that the models without battery backup will not respond during an AC power failure. • This unit is only approved to interconnect with other Kidde/Nighthawk products. It is NOT approved to interconnect with any other brand of detection product.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Operating Instructions ! CAUTION: BEFORE USING THE ALARM HUSH FEATURE, IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS. Reset Feature If the the Smoke/CO Alarm is sounding a CO alarm, pressing the test/reset button will silence the alarm. If the CO condition that caused the alert continues, the alarm will reactivate within 200 seconds.(see page 21).
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Operating Instructions Green LED The green LED will flash as described below under the following conditions: – Standby Condition (powered by AC and battery backup): The LED will be constantly on. – Standby Condition (powered by only battery backup): The LED will flash every 60 seconds.. – Smoke Alarm Memory Condition: The LED will flash every second during alarm.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Operating Instructions A A Posts FIGURE 5A FIGURE 5B NOTE: To remove the alarm when the tamper resist tab is engaged, press down on the tamper resist tab, and rotate the alarm off of the bracket (see figure 5B). NEVER IGNORE THE SOUND OF THE ALARM! Determining what type of alarm has sounded is easy with your Combination Smoke/CO Alarm. The voice message warning system will inform you of the type of situation occurring.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 What To Do If The Alarm Sounds vents to the outside (non recirculating type) will also help remove these combustible products from the kitchen. If the alarm sounds, check for fires first. If a fire is discovered follow these steps. Become thoroughly familiar with these items, and review with all family members! • Alert small children in the home. • Leave immediately using one of your planned escape routes (see page 26).
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 What To Do If The Alarm Sounds When the carbon monoxide alarm sounds: ! WARNING - Actuation of your CO Alarm indicates the presence of Carbon Monoxide (CO) which can kill you. If alarm signal sounds: 1) Operate the test/reset button PHONE NUMBER 2) Call your emergency services (Fire Dept. or 911) 3) Immediately move to fresh air - outdoors or by an open door/window. Do a head count to check that all persons are accounted for.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Battery Replacement Alarm Removal IF TAMPER RESIST FEATURE HAS BEEN ACTIVATED, REFER TO TAMPER RESIST FEATURE DESCRIPTION ON PAGE 17 FOR REMOVAL INSTRUCTIONS. Remove the alarm from the mounting bracket by rotating the alarm in the direction of the “OFF” arrow on the cover. Battery Replacement If any form of battery failure is detected the red LED light will flash and the unit will “chirp” one time, followed by the warning message “LOW BATTERY”.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 2:44 PM Battery Replacement Completely slide the battery door to the closed position. A Battery missing or improperly installed finger battery will prevent the battery door from closing and result in improper alarm operation. Replace batteries with one of the following approved brands: Duracell MN1500, MX1500, FIGURE 6 Energizer E91, Gold Peak 15A or Golden Power GLR6A . These batteries can be purchased at your local retailer.
44-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 General Maintenance To keep your Smoke/CO Alarm in good working order, please follow these simple steps: • Verify the unit's alarm and LED lights operation by pushing the test/reset button once a week. • Remove the unit from mounting bracket and vacuum the alarm cover and vents with a soft brush attachment once a month to remove dust and dirt.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 General Maintenance Carbon Monoxide Safety Information General CO Information Carbon monoxide (CO) is a colorless, odorless, and tasteless poison gas that can be fatal when inhaled. CO inhibits the blood’s capacity to carry oxygen. Possible Sources CO can be produced when burning any fossil fuel: gasoline, propane, natural gas, oil and wood.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Carbon Monoxide Safety Information CO Safety Tips Every year have the heating system, vents, chimney and flue inspected and cleaned by a qualified technician. Always install appliances according to manufacturer’s instructions and adhere to local building codes. Most appliances should be installed by professionals and inspected after installation.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Carbon Monoxide Safety Information become so disoriented they are unable to save themselves by either exiting the building, or calling for assistance. Also, young children and household pets may be the first effected. Familiarization with the effects of each level is important. Fire Safety Information Escape Plan Familiarize everyone with the sound of the smoke alarm and train them to leave the home when they hear it.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Fire Safety Information Industry Safety Standards NFPA (National Fire Protection Association) For your information, the National Fire Protection Association’s Standard 72, reads as follows: Smoke Detection.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Industry Safety Standards Consumer Product Safety Commission The Consumer Product Safety Commission (CPSC) recommends the use of at least one CO Alarm per household, located near the sleeping area. NRC Ionization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Warranty and Service Information Limited Warranty TEN YEAR LIMITED WARRANTY KIDDE warrants that the enclosed alarm (but not the battery) will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of purchase.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 Warranty and Service Information The above warranty may not be altered except in writing signed by both parties hereto. Your Kidde Combination Smoke & CO Alarm is not a substitute for property, fire, disability, life or other insurance of any kind. Appropriate insurance coverage is your responsibility. Consult your insurance agent. Removal of the front cover will void the warranty. This alarm is not intended to alert hearing impaired individuals.
2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 QUESTIONS OR FOR MORE INFORMATION Call our Product Support Line at 1-800-880-6788 or contact us at our website at www.kidde.com Kidde 1016 Corporate Park Drive, Mebane, NC 27302 Custom Assembled in China with U.S.