Product Brochure
94
KINDORF® METAL FRAMING SYSTEM METAL FRAMING CHANNEL & ACCESSORIES
T-Section Single section
3,880 1,500
3,500 1,200
3,000 950
2,500 750
T-Section Single section
5,550 2,550
5,050 1,900
4,400 1,550
3,850 1,300
3,400 970
3,000 –
2,650 –
2,300 –
Broad
channel
Narrow
channel
Single
section
2,550 1,490 770
1,780 1,040 530
1,330 770 400
1,030 600 310
820 470 240
590 380 –
420 310 –
310 230 –
4,110 3,050 1,560
2,870 2,130 1,090
2,140 1,580 810
1,660 1,230 630
1,330 980 500
8’ 1,080 790 410
890 650 330
720 540 280
7,570 6,300 3,220
5,290 4,400 2,250
3,950 3,280 1,680
3,060 2,540 1,300
2,440 2,020 1,040
1,990 1,650 840
1,650 1,360 690
1,380 1,140 580
NOTE: Values shown are for a pair of beams supporting an evenly distributed load (lbs).
For a concentrated load these values should be halved. Min. safety factor of 1.4. Multiple
angle beams should be bolted every 6 in. with bolts staggered in alternate rows.
To increase load capacity tie angles can be cut to size and bolted between beams.
T-Section Single section
8,000 3,500
7,100 2,900
6,300 2,400
5,550 1,800
4,750 1,300
4,000 1,000
3,200 –
2,400 –
NOTE: Values shown are static loads (lbs.) applied vertically to an unbraced column.
Min. safety factor of 2.1. To increase load capacity columns can be reinforced
with side braces cut to size.
KINDORF RA-225
KINDORF RA-160
—
Right angle slotted angle systems
Column loads
—
—
—
—
Beam loads