User's Manual

CAUTION
* Warning: This device is not AP/APG equipment. Do not use the device where flammable
anesthetic are present, or in environments mixture with air of with oxygen or nitrous oxide.
* The device contains sensitive electronic components.To avoid measurement errors, avoid taking
blood pressure measurements near a strong electromagnetic field radiated interference signal
or electrical fast transient/burst signal.
* Wireless communication equipment, such as wireless home network devices, mobile phones,
cordless telephones and their base stations, walkie-talkies may cause interference that may
affect the accuracy of measurements. A minimum distance of 1 foot (30 cm) should be kept from
such devices during a measurement.
* You can use this device to take your own measurement, no third-party operator is required.
* Please use the device under the environment which is provided in the user manual. Otherwise,
the performance and lifetime of the device will be impacted and reduced.
* The device may require up to 30 minutes to warm up / cool down from the minimum / maximum
storage temperature before it is ready for use.
* Warning: Excessive cuff tube lengths could cause strangulation if you don't manage them
properly.
* Warning: Do not touch output of the batteries/adapter and the user simultaneously.
* Adapter is specified as a part of ME EQUIPMENT.
* Warning: The power cord is considered the disconnect device for isolating this equipment from
supply mains. Do not position the equipment so that it is difficult to reach or disconnect.
* The blood pressure monitor, its adapter, and the cuff are suitable for use within the patient
environment.
* Warning: Do not use this device if you are allergic to polyester, nylon, or plastic.
* Warning: Only use accessories approved by manufacturer. Using unapproved accessories
might cause damage to the unit and injure users.
* Warning: If you experience discomfort during a measurement, such as pain in the arm or other
complaints, press the Power button immediately to release the air from the cuff.
* No calibration is required within two years of reliable service.
* Do not attempt to repair the unit yourself if it malfunctions. Only have repairs carried out by
authorised service centers.
* At the request of authorised service personnel, circuit diagrams, component part lists,
descriptions, and calibration procedures will be made available by the manufacturer or
distributor.
* It is recommended that the performance should be checked after repair, maintenance, and
every two years of use, by retesting the requirements in limits of the error of the cuff pressure
indication and air leakage (testing at least at 50 mmHg and 200 mmHg).
* Warning: Do not use the device while under maintenance, or being serviced.
* Store your device, cuff and adapter in a clean and dry place, protect it against extreme moisture,
heat, lint, dust and direct sunlight. Never place any heavy objects on it.
* Make sure the rubber tube of the cuff is not squeezed, stretched, or kinked during storage.
* Warning: Keep the device, cuff, and batteries away from children as they may pose a risk of
choking or strangulation if used improperly.
* Clean both device and cuff with a soft, dry cloth. If necessary use a dampened cloth and natural
detergent. Do not use alcohol, benzene, or other harsh chemicals.
* Do not wash the cuff in a washing machine or dishwasher!
* The service life of the cuff may vary by the frequency of washing, skin condition, and storage
state. The typical service life is 10000 times.
* Dispose of accessories, detachable parts, and the device according to the local guidelines.
Display and Symbols
1
Systolic blood pressure
reading
2
Blood pressure level
3
Diastolic blood pressure
reading
4
Pulse display
5
Heartbeat symbol /
Irregular heartbeat
6
Average value symbol
7
Date / Time display
8
9
10
Excessive body motion
detector symbol
11
Cuff wearing OK symbol
12
13
Battery symbol /
High power symbol /
Low battery symbol
User ID symbol
Memory symbol
mmHg
7
INTRODUCTION INTRODUCTION
6
3
2
1
8
13
12
11
10
9
4
57 6