H Series Brochure

Hydronic. Comfort everywhere.
King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738 / www.king-electric.com
6
MODEL
FINS
PER
INCH
FT. OF WATER
PRESSURE
DROP @ 2 GPM
Btu@2GPM
120ºF
48ºC
140ºF*
60ºC
160ºF*
71ºC
180ºF
82ºC
200ºF
93ºC
AMPS RPM CFM
H412 2/3
4 .36 High Speed 1,800 2,500 3,600 3,500 4,100 .54 2000 80
4 .36 Low Speed 1,200 1,400 1,700 2,000 2,300 .51 1750 50
H412 3/4
8 .36 High Speed 2,200 3,100 4,000 4,800 6,100 .54 2000 80
8 .36 Low Speed 1,200 1,800 2,400 3,000 3,800 .51 1750 50
H612 4/5
4 .54 High Speed 3,600 4,700 5,800 7,100 8,500 .48 2550 120
4 .54 Low Speed 3,200 4,000 5,000 6,100 7,300 .40 1850 105
H612 6/8
8 .54 High Speed 4,100 6,000 7,600 9,100 10,500 .48 2500 120
8 .54 Low Speed 3,700 5,200 6,500 7,900 9,600 .40 1850 105
Hydronic. Comfort everywhere.
H series
Aqua stat: turns on fan when radiant plates reach 115°F.
To specify aqua stat add AS to model number.
Fan switch: optional two-speed fan switch with center off.
To specify fan switch add FS to model number.
Grille colors: available in white, black or almond.
To specify, add GW for white, GB for black, or GA for almond.
Coils are made of copper alloy 122 manufactured to ASTM B-75 specifications.
Brazing alloy is AWS-BCUP2 for use with potable water systems.
Electrical circuit size: 15 amp maximum.
Btu ratings based on 68º entering air. To calculate 1 GPM, multiply by 0.95. To calculate 4 GPM, mulitply by 1.05.
H
series
MODEL
FINS
PER
INCH
FT. OF WATER
PRESSURE
DROP @ 2 GPM
Btu@2GPM
120ºF
48ºC
140ºF*
60ºC
160ºF*
71ºC
180ºF
82ºC
200ºF
93ºC
AMPS RPM CFM
HT412 2/3
8 .36 High Speed 1,700 2,500 3,400 4,600 5,200 .54 2000 83
8 .36 Low Speed 1,600 2,400 3,200 4,000 5,000 .51 1800 76
HT612 4/5
8 .54 High Speed 2,800 4,000 5,100 6,900 8,200 .54 2000 83
8 .54 Low Speed 2,400 3,250 4,350 6,000 6,500 .51 1800 76
HT612 5/6
8 .72 High Speed 3,600 5,000 6,600 7,500 9,950 .54 2000 83
8 .72 Low Speed 3,200 4,300 5,400 7,000 8,400 .51 1800 76
Hydronic Small
Hydronic toe-space, under-cabinet
H
HT
Model Number Volts Can Size Grille Size
H412 – all versions 120 9½"h x 14
3
/8"w x 4¾"d 10½"h x 15¾"w x
7
/8"d
H612 – all versions 120 11"h x 14
3
/8"w x 4 ¾"d 12 ½"h x 15 ¾"x
7
/8"d
Model Number Volts Can Size Grille Size
HT – all versions 120 3
3
/8"h x 18¼"w x 13½"d 3
3
/8"h x 20"w x ¾"d
Model Number Legend
H 6 12 6/8 AS-FS GW
GW Grill White
AS-FS Aqua Stat / Fan Switch
6/8 6000 Btu heat output @ 140 Degree
8000 Btu heat output @ 160 Degree water input
12 Voltage 120 water input
6 Number of copper tubes in coil
H H Series Hot Water
* most common water temperature range
* most common water temperature range
All King hydronic heaters are
tested to UL 1995 standards.
Approved for USA and Canada
CSA /C22.2
1800 to 10,500 Btu
1700 to 9950 Btu