Use and Care Manual

w_install_2012.pub
Maintenance & Warranty
King Electrical Mfg. Co. 9131 10th Ave So. Seattle, WA 98108 206-762-0400 www.king-electric.com
4
Maintenance & Cleaning: Basic maintenance is listed below and should be performed annually. When necessary, any
required servicing should be performed by qualified service personnel. Your heater will give you years of service and
comfort with only minimum care. To assure efficient operation follow the simple instructions below.
WARNING: Turn the electrical power OFF at the electrical panel board (circuit breaker or fuse box) and
lock or tag this panel board door to prevent someone from turning on power while you are working on
this heater. Failure to do so could result in serious electrical shock, burns, or possible death.
Remote Wall Thermostat
Warranty Information
King Electrical Manufacturing Company will repair or replace, without charge to the original owner, any W Series heater found
to be defective or malfunctioning within 1 year of installation. This warranty requires the owner or his agent install the equip-
ment in accordance with the National Electrical Code, any other applicable heating or electrical codes, and the manufac-
turer’s installation instructions. It further requires that reasonable and necessary maintenance be performed on the unit. Fail-
ure to properly maintain the unit will result in the warranty being voided. The company is not liable for abuse or misuse of
product as may be finally determined by the company. The customer shall be responsible for all costs incurred in the removal
or reinstallation of products, including labor costs and shipping costs incurred to return products to King Manufacturing. King
Manufacturing will repair or replace, at our option, at no charge to the customer with return freight paid by King. King Manu-
facturing shall not be liable for consequential damages arising with respect to the product, whether based upon negligence,
tort, strict liability or contract. No other written or oral warranty applies, nor any warranties by representatives dealers, em-
ployees of King, or any other person. All returns require a King Return Goods Authorization (RGA); Unauthorized returns will
be refused. Do not return malfunctioning/defective products to store.
1. Before removing grille, turn the electrical power OFF. Circuit breakers are often not marked correctly and turn-
ing the wrong breaker off could mean electricity is flowing to the heater, even if the heater does not appear to
be working. If you are uncomfortable working with electrical appliances, unable to follow these guidelines, or do
not have the necessary equipment, consult a qualified electrician. Once you verify the power is off completely,
proceed to the next step.
2. Remove screws and take off grille. Wash grille with hot soapy water and dry immediately
3. Using a hair dryer or vacuum on blow cycle, hold the fan in place to prevent it from turning and blow debris back
through the element. Do not touch element. Vacuum lose debris without touching the elements.
4. Replace grille and secure with screws.
5. Turn thermostat to desired setting.
6. Turn power back ON at the electrical panel board.
Before cleaning this heater, the heating element of the heater must be cool. Figure 2
Figure 6
Connection Diagram for Wall Mounted Single Pole Thermostat
1. Red thermostat wire to black power supply wire.
2. Black thermostat wire to black heater wire.
3. White power supply wire to white heater wire.
4. Connect all bare ground wires together.
Connection Diagram for Wall Mounted Double Pole Thermostat
1. Connect the two red thermostat wires to the black
and white power supply wires.
2. Connect the two black thermostat wires to the black
and white heater wires.
3. Connect all the bare ground wires together.