Instructions / Assembly

1.
Never operate this appliance within 10 feet (3.05m) of any structure, combustible material or
other gas cylinder. Never operate this appliance within 25 feet (7.5m) of any flammable liquids or
vapors.
2. There must be no combustibles or roof overhead.
3. Keep 24” (.61m) of space between the LP gas cylinder and the appliance.
4. The LP gas cylinder and appliance must be located so that any wind is blowing the heat of the appliance away
from the propane cylinder. This also helps fire prevention by blowing the flames of a grease fire away from the
propane cylinder.
5. Center the pot over the burner on the cooker. Do NOT use any pot larger than the recommended size for your
cooker as listed below:
Cooker Height Maximum Pot Size Pot - Height/Diameter
12” (30.5 cm) 32 qt. pot 12” x 14” (30.5 cm X 35.5 cm)
14.5” (37 cm) and Taller 30 qt. pot 16”x12 3/8” (40.6 cm X 31.5 cm)
6. If you have purchased model #2835 or 2836, this model is approved for use with up to a 36 qt. (34.1L)
pot. These pot dimensions are equivalent to 10.13” (25.73 cm) tall x 16.63” (42.24 cm) wide x 13.38” (34 cm)
depth. If your model number is not 2835 or 2836 refer to #5 above for the maximum pot size to be used with
your cooker.
23
PLACEMENT INSTRUCTIONS
CONNECTION INSTRUCTIONS
1. Check that your hose assembly is set to not allow gas flow. Turn the regulator control counterclockwise
until it stops. This is the OFF position.
2. Attach the regulator to the cylinder valve by turning the Type 1 fitting clockwise. Hand tighten with the
regulator positioned upright. Refer to the appropriate assembly diagram for the appliance, page 12,
Figure 1 or 2.
3. Perform the Leak Test:
4. Before lighting the cooker, check that the venturi tube is free of obstruction and that the orifice is properly
threaded into the venturi tube as per the hose connection instructions on pg. 12. Both situations must be
corrected if necessary before lighting to prevent flashback.
LEAK TEST
Before lighting the appliance, a thorough leak test must be satisfactorily completed using
a non-ammonia soapy water solution (50% non-ammonia soap and 50% water). This is to be
applied with a small brush to all gas joints after the cylinder valve is opened (no more than
1/2 turn). If bubbles are seen, indicating a leak, turn off the cylinder and tighten the leaking
connection until a further leak test shows no leaks.
If tightening the connection does not stop the leak, call Metal Fusion, Inc. (800) 783-3885,
for assistance.
NEVER USE HOSE/REGULATOR ASSEMBLY IF LEAKING.
FIGURE 1
(3.05m)
(.61m)
(3.05m)
Keep twenty-four inches between the
cylinder and the appliance. Placing the
cylinder too close to the appliance could
result in fire or explosion which could cause
property damage, personal injury or death.
The hose connecting the appliance to the
tank poses a trip hazard. Do not step over
the hose or walk between the cylinder and
appliance. Tripping could cause the
appliance or cylinder to tip over, leading to
fire or explosion which could cause
property damage, personal injury or death.
10 FEET
WIND DIRECTION
GROUND LEVEL
LP
GAS
TANK
24 INCHES
10 FEET
to
NEAREST
COMBUSTIBLE
(All Directions)