LIGHTING AND OPERATING INSTRUCTIONS
THE COOKER MUST NOT BE LIT UNTIL THE PRECEDING
PLACEMENT INSTRUCTIONS HAVE BEEN COMPLETELY FOLLOWED.
FOR MODELS WITH ADJUSTABLE REGULATORS
1. Check the casting to make sure it is set up as per the illustration (Figure 1).
2. Make certain that the regulator control is turned to OFF by turning it counterclockwise until it reaches the stop.
3. Open cylinder control valve by turning it counterclockwise as per the diagram (Figure 2).
4. Insert a multipurpose lighter through the hole in the shroud as per Figure 4, or use a paper book match placed
above the casting as per Figure 5. Turn the regulator control toward the “ON” position until ignition occurs. Turning
the regulator control clockwise increases the gas pressure to the burner and hence the flame size (Figure 2).
When lighting the stove, if ignition does not occur in 3 to 5 seconds, turn the regulator and cylinder valve off. Wait
5 minutes for gas to disperse. Repeat procedure.
5. Check that the flame is blue and that the flames are emitted from every port in the casting. If not, rotate the air
shutter position until there is a blue flame. Opening the shutter too much will cause the flame to “Lift” off the burner
(Figure 6). If there is a yellow flame, or if some ports have no flame, this indicates there may be an obstruction in
the venturi tube or ports. Check the maintenance instructions on page 24 for more information regarding a yellow
flame.
6. Always monitor the flame throughout the cooking process. If at any point in the cooking process the flame is
accidentally extinguished, immediately turn the regulator and cylinder valve OFF. Wait 5 minutes for gas to disperse
and relight the cooker according to the lighting instructions (#1-#5) in this section.
NEVER PUT HANDS OR FACE DIRECTLY OVER BURNER WHILE LIGHTING OR
WHILE THE APPLIANCE IS LIT.
.61m
Air Shutter
Turn triangle handle
toward ON
(Counterclockwise)
Turn triangle handle
toward ON
(Counterclockwise)
Turn T-handle
toward ON
(Clockwise)
Turn T-handle
toward ON
(Counterclockwise)
24”