Owner's Manual Original Instructions Window Type Air Conditioner Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or send an email to for the electronic version.
GJC10BL-A6NRNC5C GJC10BL-A6NRNC5D
Contents Operation and Maintenance Installation Operation Notices Installation Notice The Refrigerant...............................1 Safety Precautions..........................3 Precautions.....................................6 Parts Name .....................................7 Installation and Maintenance.........19 Preparation before installation.......21 Operation Guide Function and Control.......................8 Introduction of remote controller....11 Instruction for fan direction adjusting.....
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they are away from the appliance.
Please read this operating manual carefully before operating the unit. Caution, risk of fire. Before use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The figures in this manual may be different with the material objects, please refer to the material objects for reference.
WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.) Do not pierce or burn. Be aware that refrigerants may not contain an odor. Adopt R32 flammable refrigerant. When maintaining or disposing the unit, the refrigerant inside the system must be eliminated.
Safety Precautions DANGER Indicates a hazardous situation that, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. NOTICE Indicates important but not hazard-related information, used to indicate risk of property damage. Indicates a hazard that would be assigned a signal word WARNING or CAUTION.
Safety Precautions CAUTION When the air filter is to be removed, do not touch the metal parts ofthe unit. It may cause an injury. ! When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury. ! Stop operation and close the window in storm or hurricane. Operation with windows opened may cause wetting of indoor and soaking of household furniture.
Safety Precautions CAUTION “ ” Operation of Current Device CAUTION: Please contact Customer Service. with a new cord - please contact Customer Service.
Precautions Warning Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock. purpose socket. Otherwise, it may cause r, otherwise the remote controller may be broken. Do not spray water on air conditioner. It may cause electric shock or mal unction. personal injury or damage. r, or put heavy objects.
Parts Name upper guide rail Control panel Air outlet frame Fan direction adjusting rod Air-in panel TEST 7 RESET Power cord
Function and Control After putting through the power, air conditioner will give out a sound and indicators on control panel will be on. After that, you operate the air conditioner through remote controller or control panel. Light indicates the unit is in the temperature or delay time Set mode.
Press this button can turn on or turn off air conditioner. NOTE:Press this button to turn on air conditioner, the unit will operate in Energy Save mode; if the unit is energized after power failure, the unit will still operate according to the status before power failure. Mode button Press this button can your required operation mode in turn. Corresponding indicator will be on.
Filter check button After fan rotates for 250h totally, lamp of cleaning filter is on to remind customer clean it. Note: When user cleaned the filter, press Filter check button to clear the operation time. Meanwhile, the warning indicator will turn off. / button Under temperature setting status, after each pressing of “ ” or “ ” button, temperature will increase or decrease 1°C. Temperature setting range: 16~30°C.
Introduction of remote controller Note: This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn’t have, if press the corresponding button on the remote controller that the unit will keep the original running status.
- / + button Pressing + or - button once will increase or decrease set temperature by 1°F(°C). Hold + or - button for 2s, set temperature on remote controller will change quickly. Release the button after your required set temperature is reached. Under timer setting status, after each pressing of “+” or “-” button, time will increase or decrease 0.5h . Hold “ +” or “-” button, 2s later, time displayed on dual-8 nixie tube will change quickly.
Replacement of Batteries in Remote Controller 1. Press the mark “ ” on back cover of batteries box cover for remote controller with fingers as shown in the fig, and then remove the batteries box cover along the arrow direction. Battery 2. Replace with two #7 (AAA 1.5V) dry batteries. Make sure positions for “+” pole and “-” pole are correct. 3. Reinstall batteries box cover.
Instruction for fan direction adjusting You can adjust the fan direction adjusting rod to select left&right air outlet direction according to your requirement. Fan direction adjusting rod You can adjust the air outlet frame to select up&down air outlet direction according to your requirement.
Clean and Maintenance Warning ` Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock. ` { ` { | r. 1. Open the panel Pull the groove at both sides of panel forcibly to open (below 45 degree) dissolved with neutral abluent, and then put it under the shady place. Notice: ation environment , you can increase the clean times.
Qualification of workers Qualification of the working personnel for maintenance, service and repair operations should according to CAS/UL 60335-2-40:17 Annex HH.. Every working procedure that affects safety means shall only be carried out by competent persons according to Annex HH. Special training additional to usual refrigerating equipment repair procedures is required when equipment with FLAMMABLE REFRIGERANTS is affected.
" % serio sly (s c as static press e, { / { controller is 8m. Do not exceed % is Air conditioner { can't receive signal from % remote controller or remote { controller is not sensible.
Malfunction code When there's abnormal phenomenon for the air conditioner, dual-8 nixie tube displays corresponding malfunction code: Malfunction code FO、F1、F2、F4 H3、E8 Solution " High temperature protection of condenser Note: HS malfunction codes are only applicable for electric heating model. WARNING If there's below phenomenon, please turn off the air conditioner and disconnect the power immediately. After that, please contact dealer at once.
Installation and Maintenance Warning { { # " prevent electric shock, casualty and other accidents. " # $ % & " Basic requirement Installing the unit in the following places may cause malfunction.
Requirements for Electric Connection Safety precaution Q | [ " | " { = #
Preparation before installation Tools for installation Phillips screwdriver Level bar Screwdriver Scissors Pencil Measuring tape Products and spare parts list Window type unit Flexible screen Sealing strip ( with adhesive) Sealing strip ( without adhesive) screws(6) Frame locking(2) Fixing bracket for window Remote controller Batteries Owner's manual 2
Window types and requirements Note: types of window, you may need to adjust the window. " | for details. strap, brick or metal.
Installation procedure Location How to install: Choose a location where there are no any obstacle surrounding the unit, and the plug is accessible. + cording to the following diagram. The distance between the air conditioner and the around obstacles should meet the requirement as below: over 300mm (upper side), over 500mm (left side), over 500mm (right side), over 1500mm (front side) and over 500mm (rear side).
Step 2: Stick sealing strip Cut the sealing strip into proper length. Tear off the paster and then stick the sealing strip at the lower part of the window frame. Sealing strip ( with adhesive) Step 3: Put the air conditioner 1. 2 Ask 2 persons to put the air conditioner at the windowsill, and the lower guide rail should be stick at the windowsill. Upper guide rail stays at the middle lower side of window and then window can stick to the upper guide rail when closing r it.
, $ % *0 "4 # Plastic window Wooden window 5 % % Cut the sealing strip into the length same to the width of window. Plug the sealing strip between glasses and window to prevent rain and insects getting into the room. Note: If sealing strip is not proper to your window, you can select other proper materials to replace it.
Step 6: Drain water To get the maximum cooling efficiency , the air conditioner is designed to splash the condensate on the condenser coil. If the splashing sound annoys you, you can provide an outside drain by using the following procedure, which may however cause a small loss of performance. 1. The air conditioner have the drainage gasket-Figure 1. 2. Remove the drainage gasket from the body base plate- Figure 2.
Safety operation of flammable refrigerant Q All the work men who are engaging in the refrigeration system should bear the for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised 2. It can only be repaired by the method suggested by the equipment’s manufacturer. Installation notes 2. The air conditioner must be installed in a room that is larger than the minimum room area.
Welding 1. If you should cut or weld the refrigerant system pipes in the process of maintaining, please follow the steps as below a. Shut down the unit and cut power supply b. eliminate the refrigerant c. vacuuming d. clean it with N2 gas e. cutting or welding f. carry back to the service spot for welding 2. The refrigerant should be recycled into the specialized storage tank. and it’s well-ventilated. Filling the refrigerant ferent kinds of refrigerant won’t contaminate with each other.
Safety notices for maintenance Storage after moving the unit 1. Do not puncture or light the unit. 2. The unit shall be stored in a room without continuous fire source (e.g. naked fire, litten gas appliance, operating electric heater). 3. The unit shall be stored in a ventilated place; the ventilation device shall operate normally and ventilation port shall be without obstacle; 4. Check the unit periodically to see if there is collision mark and if the appearance is good. 5.
Disposal and recycle Label The unit shall be labeled with data and note after scrapping and discharging refrigerant. Make sure the label on the unit can reflect the R32 refrigerant which it has been filled. Recycle It's recommended to remove the refrigerant in the system before maintenance and disposal. Put the refrigerant into the specialized refrigerant tank with refrigerant label. The refrigerant tank shall be equipped with pressure-relief valve and cut-off valve, which are in good condition.
Information on servicing Checks to the area Prior to beginning work on systems containing FLAMMABLE REFRIGERANTS, safety checks are necessary to ensure that the risk of ignition is minimised. General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off.
Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation. Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification,damage to seals, incorrect fitting of glands, etc.
Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/extinguished.
Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but prior to commissioning.
FLAMMABLE REFRIGERANTS, ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available.
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai,Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: Web: www.gree.