2017 2016 2015 2005 Gree's sales revenue exceeded 15.08 billion USD. Gree has topped No.1 in production and sales volume of residential air conditioners for 13 consecutive years. Gree's sales revenue exceeded 16.51 billion USD. Gree's sales revenue exceeded 22.21 billion USD.
ABOUT KINGHOME Kinghome is a brand of Gree. Gree Electric Appliances, Inc. of Zhuhai was founded in 1991 and it was listed on the Shenzhen Stock Exchange in November 1996. In the beginning, Gree was only a company that assembled residential air conditioners. Now it has grown into a diversified technological global industrial group that has expanded its business to air conditioners, home appliances, high-end equipment, and communication equipment.
AWARDS AND CERTIFICATES ISO 9001 Quality ISO 14001 Environment ISO 18001 Occupation Canadian CSA European Communities American UL System Certificate Management System Healthy Safety System Certificate CE Certifcate Certifcate Certificate Certificate EQM German GS European EMC Argentina Sale China EMC Certifcate Certifcate Certifcate Certifcate Australia RCM CQC Certifcate SASO Certifcate Russian Safety Certifcate German TüV 3C Certifcate Certifcate Certifcate Mexico NOM Safety
CONTENT 14 28 Wall-mounted Type Light Commercial
G-cloud and Google Assistant Cloud Connection Google Assistant is usually considered as an upgraded or extended version of Google Now and an extended version of the existing "OK Google" voice control. Google Assistant can cover all the voice commands, voice search, voice-activation device control functions involved in Google Now or "OK Google", and integrate them into a personalcentered interactive dialogue AI experience.
Principle of Connection between G-cloud and Google Assistante Cloud Data Synchronism, Query Device Status, Execute Command provides continuous harmonization of data over time. A voice comman"turn on the lights" in the kitchen and a third-party device can handle the commands. How to Access Google Speakers and Google Home Configure Google Home and add devices to Home Control, bind the Smart Life app account, use Google Home App to control the smart devices—voice command.etc.
Triple-cylinder Two-stage Rotary Compressor of Variable Volume Ratio Gree self-developed technology “triple-cylinder two-stage rotary compressor of variable volume ratio” achieves reliable heating performance in ultra-low ambient temperature. This technology improves the heating capacity of the air conditioners in an extreme cold environment greatly. Heating capacity will not be decreased even when outdoor ambient temperature is as low as -4 ℉. It’s accredited by the expert team as a "world leading" level.
08
ULTRA LOW TEMPERATURE Adopt core technology triple-cylinder compressor, "2+1 structure", which can work excellently in geographic areas with extreme climate conditions.
Heating Capacity Heating 100% Competitor 90% · 100% heating capacity to -4 ℉ 80% · 80% heating capacity to -22 ℉ 70% · Sustainable heating capacity to -31 ℉ Kinghome 60% 50% 5℉ -4℉ -13℉ -22℉ Ambient Temp Cooling Capacity 100% Cooling Kinghome Ultra Heat Multi Zone , its Ultra Heat Unit Conventional 90% 80% 70% capacity is improved maximum by 40% 60% compared with conventional Multi Zone.
Icon Interpretation · Healthy and comfortable Electrostatic dedusting filter, catechin The indoor fan operates at a low fan filter, active carbon filter. speed and the operating noise reduces to the lowest. Quiet Design Healthy Filters It can effectively sterilize and provide The unit will operate at a super high the air with more negative oxygen fan speed in cooling and heating ion. mode for fast cooling and heating.
· Safe and reliable It adopts special anti-corrosion The electric box adopts new BMV material, corrosion resistance and fireproof material, which is safe and acid resistance of air conditioner will reliable. be reinforced under humid environ- Golden Fin ment.
Products Overview Wall-m ounted Ty pe Name Capac ity (Btu/h) CANNA DC Inverter , R410A 14 LILAC DC Inverter , R410A 17 VIOLET DC Inverter , R410A 19 ORCHID DC Inverter , R410A 23 TULIP DC Inverter , R410A 26 9000 12000 18000 24000 30000 36000 Page Light Com m erc ial Name Capac ity (Btu/h) PTAC On-Off, R410A 7000 9000 12000 15000 Page 28 Name Capac ity (Btu/h) 18000 24000 30000 36000 42000 48000 54000 56000 Multi Zone (Regular) DC Inverter , R410A 31 Multi Zone (Ultra
[Wall-mounted type] CANNA I Feel Turbo Button -4℉ Heating 46.
· Soft startup · Long air supply range. With unequal-distance air duct design and simulation optimization for long-distance air supply. Off-peak power supply to migrate the pressure of public power grid. Turbo · Fast cooling and heating. The compressor operates in high frequency to quickly cool down or heat up the room temperature. · Fireproof electric box with higher safety performance.
16 SEER Model KW09HQ1B8A KW12HQ1B8A KW09HQ1B8D KW12HQ1B8D KW18HQ1B8D KW24HQ1B8D Function Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Capacity Cooling Btu/h 9000 12000 9000 12000 18000 22000 Heating Btu/h 9600 13000 9500 13000 19000 23000 16/9 16/9 16/9 SEER/HSPF Power Supply Power Input Rated Current Air Flow Volume - 16/9 16/9 16/9 Ph,V,Hz 1Ph,115V,60Hz 1Ph,115V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/23
[Wall-mounted type] LILAC I Feel Turbo Button -4℉ Heating 46.
· Soft startup Off-peak power supply to migrate the pressure of public power grid. Turbo · Long air supply range. With unequal-distance air duct design and simulation optimization for long-distance air supply. · Fast cooling and heating. The compressor operates in high frequency to quickly cool down or heat up the room temperature. · Fireproof electric box with higher safety performance.
[Wall-mounted type] VIOLET I Feel Turbo Button -4℉ Heating 46.
· Soft startup Off-peak power supply to migrate the pressure of public power grid. · Long air supply range. With unequal-distance air duct design and simulation optimization for long-distance air supply. Turbo · Fast cooling and heating. The compressor operates in high frequency to quickly cool down or heat up the room temperature. · Fireproof electric box with higher safety performance.
SEER Model KW09HQ2B8A KW12HQ2B8A KW09HQ2B8D KW12HQ2B8D Function Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Capacity Cooling Btu/h 9000 12000 9000 12000 Heating Btu/h 9900 12200 11000 13000 SEER/HSPF - 23/10.5 22/10.5 23/10.5 22/11 Ph,V,Hz 1Ph,115V,60Hz 1Ph,115V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz Cooling W 700 960 630 960 Heating W 930 990 1020 1100 Power Supply Power Input Rated Current Air Flow Volume Cooling A 11.27 11.54 5.
Model KW18HQ2B8D KW24HQ2B8D KW30HQ2B4D KW36HQ2B4D Function Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Capacity Cooling Btu/h 18000 22000 28000 33600 Heating Btu/h 19800 23000 28400 34600 SEER/HSPF Power Supply Power Input Rated Current Air Flow Volume - 20/10 20/10 18/9 18/9 Ph,V,Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz Cooling W 1435 1760 2700 4100 Heating W 1730 2000 2800 3800 Cooling A 10.39 14.
[Wall-mounted type] ORCHID Features: Standard Optional Wifi Control 3D Airflow I Feel -30 。C Heating 54。C Cooling 4 Sleep curves Dehumidifying Light Function R32 Auto Restart Quiet Design 7 Fan Speeds Lock LED Display Auto Clean 46.
Energy-saving two-stage compressor Gree two-stage inverter compressor Applicable temperature range 109.4℉ Reliable operation within -22℉-129.2℉ -22℉ 5℉ Heating capacity and cooling Without Improvement capacity are not improved improved by 30% Cooling capacity is Energy-saving two-stage improved by 35% compressor, outstanding The highest temperature at temperature range from -22 ℉ to 129.2 ℉. Reliable operation within 5℉-109.
30.5 SEER Model KW09HUCA4D KW12HUCA4D KW18HUCA4D Function Cooling/Heating Cooling/Heating Cooling/Heating Capacity Cooling Btu/h 9000 12000 18000 Heating Btu/h 9000 13000 19000 SEER/HSPF Power Supply Power Input Rated Current Air Flow Volume - 30.5/10.5 23/10.5 21/10.5 Ph,V,Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz Cooling W 570 940 1440 Heating W 630 1220 1800 Cooling A 6.2 6.5 10.4 Heating A 6.5 6.9 10.
[Wall-mounted type] TULIP Features: Standard Timer Auto Clean Auto Restart LED Display Lock Compact Design Clock Display Turbo Button -4℉ Cooling -22℉ Heating 3D Airflow Wifi Control Automatic Operation Intelligent Defrosting Comfortable Sleep Mode Cold Air Prevention I Feel Healthy Filters Golden Fin Wired Controller Optional Self-diagnosis 26
· Shell-shape side face, 50μ depth for higher quality. Capacity 9000 Btu/h SEER=38.0 · Heating under ultra-low temperature. It can conduct 100% powerful heating under -4 ℉ , and heating energy efficiency under -22 ℉ is 80%. · High-efficiency and energysaving, SEER of 9000Btu/h cooling model can reach 38.0.
[Light Commercial] PTAC Quiet Design Auxiliary Heating Features: Auto Restart Self-diagnosis Standard LED Display Optional Fresh Air Supply Ventilation 28
· It adopts large power ceramic PTC electric heater for high security (no dry-burning, no short circuit, no electric leak). · Powerful cooling capacity under high temperature: fast cooling, precise temperature control, and small temperature fluctuation.
· Wide capacity range (1600W-3600W). · Quiet design, noise is as low as 39dB. On-Off R Model Function KPA07B2D KPA09B2D KPA12B2D KPA15B2D Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling Btu/h 7000/7200 9200/9400 11600/11800 14200/14500 Heating Btu/h 5800/6000 8100/8300 10400/10600 13000/13300 EER - 3.81 3.55 3.4 3.05 COP - 3.6 3.5 3.4 3.
[Light Commercial] MULTI MULTI ZONE (REGULAR) Features: Standard Optional Auto Restart High Efficiency Self-diagnosis Timer Lock Compact Design Easier Maintainability Centralized Control Turbo Function Inner Groove Copper Intelligent Defrosting Comprehensive Protection Wide Voltage Range Wide Operation Range Low Voltage Startup Long-distance Monitoring 31
Capacity Indes(Btu/h) 9000 12000 18000 21000 24000 23SEER VIOLET WALL MOUNT 30.5SEER ORCHID LOW ESP DUCTED HIGH ESP DUCTED COMPACT 4-WAY CASSETTE FLOOR CEILING CONSOLE · Regular Multi Zone 4 has no 0.5W standby function, while it has electric heating belt; · Capacity range from 14 to 42K Btu/h can be widely used in a residential house, hotel, business office and especially applicable in variable loading situation.
Two Indoor Units 09+09 KM18H4O 09+12 12+12 Two Indoor Units KM24H4O Three Indoor Units 09+09 09+09+09 09+12 09+09+12 09+18 09+09+18 12+12 09+12+12 12+18 12+12+12 18+18 / Two Indoor Units KM30H4O 09+09 12+12 9+9+9 9+9+9+9 09+12 12+18 9+9+12 9+9+9+12 09+18 18+18 9+12+12 9+9+9+18 / / 9+9+18 9+9+12+12 / / 9+12+18 / / / 12+12+12 / / / 12+12+18 / / / / / Two Indoor Units KM36H4O Three Indoor Units Four Indoor Units 9+9 21+21 9+9+9 9+21+21 9+9+9+9 9+12+1
Three Units Two Units KM48H4O Four Units 9+18 9+9+9 9+21+21 18+18+18 9+9+9+9 9+12+12+12 12+12+12+12 9+21 9+9+12 9+21+24 18+18+21 9+9+9+12 9+12+12+18 12+12+12+18 9+24 9+9+18 9+24+24 18+18+24 9+9+9+18 9+12+12+21 12+12+12+21 12+12 9+9+21 12+12+12 18+21+21 9+9+9+21 9+12+12+24 12+12+12+24 12+18 9+9+24 12+12+18 18+21+24 9+9+9+24 9+12+18+18 12+12+18+18 12+21 9+12+12 12+12+21 21+21+21 9+9+12+12 9+12+18+21 12+12+18+21 12+12+18+24 12+24 9+12+18 12+12+24 21+21+24 9+9+1
Outdoor Unit Model Capacity KM18H4O KM24H4O KM30H4O KM36H4O Cooling Btu/h 18000 24000 28400 34000 Heating Btu/h 19000 26000 30000 42500 - 22/10.5 21/10.5 21/10.5 21/10.5 SEER/HSPF Power Supply Ph,V,Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz Cooling W 1.44 1.92 2.27 2.72 Heating W 1.52 2.05 2.35 3.37 Airflow Volume CFM 1883.2 2354 2354 4531.
VIOLET Split AC KW09HQ2B8DI KW12HQ2B8DI KW18HQ2B8DI Cooling Btu/h 9000 12000 18000 22000 Heating Btu/h 11000 13000(3100~18800) 19000 23000 Ph,V,Hz 1Ph, 208/230, 60Hz 1Ph, 208/230, 60Hz 1Ph, 208/230, 60Hz 1Ph, 208/230, 60Hz m³/h 640/490/410/290 680/490/410/290 950/830/700/570 1200/1100/1000/900 Model Capacity Power Supply Air Flow Volume CFM 376/288/241/170 400/288/241/171 559/488/412/335 706/647/588/530 dB(A) 43/39/35/29 45/39/35/29 47/43/40/39 48/44/40/36 Gas inch(mm)
COMPACT 4-WAY CASSETTE Model Capacity KM12HK1DI KM18HK1DI Cooling Btu/h 12000 14400 22800 Heating Btu/h 13000 16000 27400 Ph,V,Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz m³/h 600/500/450 600/500/450 1180/950/850 CFM 353/294/265 353/294/265 694/559/500 dB(A) 44/41/38/34 47/45/41/35 47/45/41/36 mm 596×596×240 596×596×240 840×840×240 inch 30-5/8×30-5/8×11-3/4 23-1/2×23-1/2×9-1/2 33-1/8×33-1/8×9-1/2 mm 23-1/2×23-1/2×9-1/2 778×738×300 963×963×325 inch 778×7
[Light Commercial] MULTI ZONE (ULTRA HEAT) Features: Standard High Efficiency Intelligent Defrosting Lock Compact Design Memory Function Timer Turbo Function Self-diagnosis Wide Voltage Range Comprehensive Protection Easier Maintainability Inner Groove Copper Centralized Control Long-distance Monitoring Weekly timer Wired Controller Optional Low Voltage Startup 38
MULTI ZONE (ULTRA HEAT) Operating Condition (temperature) Normal Operating Condition(temperature) Item Outdoor Condition Indoor Condition Outdoor Condition DB(℉) WB(℉) DB(℉) WB(℉) DB(℉) 95 47 75.02 42.98 80.06 69.98 66.92 60.
Two Indoor Units KM48UH5O Three Indoor Units Five Indoor Units Four Indoor Units Six Indoor Units Seven Indoor Units 9+18 9+9+9 12+12+12 9+9+9+9 9+12+12+18 9+9+9+9+9 9+9+9+9+9+9 9+9+9+9+9+9+9 9+21 9+9+12 12+12+18 9+9+9+12 9+12+12+21 9+9+9+9+12 9+9+9+9+9+12 / 9+24 9+9+18 12+12+21 9+9+9+18 9+12+12+24 9+9+9+9+18 9+9+9+9+9+18 / 12+12 9+9+21 12+12+24 9+9+9+21 9+12+18+18 9+9+9+9+21 9+9+9+9+12+12 / 12+18 9+9+24 12+18+18 9+9+9+24 9+12+18+21 9+9+9+9+24 9+9+9+12+12+12 / 1
VIOLET Split AC KW09HQ2B8DI KW12HQ2B8DI KW18HQ2B8DI Cooling Btu/h 9000 12000 18000 22000 Heating Btu/h 11000 13000(3100~18800) 19000 23000 Ph,V,Hz 1Ph, 208/230, 60Hz 1Ph, 208/230, 60Hz 1Ph, 208/230, 60Hz 1Ph, 208/230, 60Hz m³/h 640/490/410/290 680/490/410/290 950/830/700/570 1200/1100/1000/900 Model Capacity Power Supply Air Flow Volume CFM 376/288/241/170 400/288/241/171 559/488/412/335 706/647/588/530 dB(A) 43/39/35/29 45/39/35/29 47/43/40/39 48/44/40/36 Gas inch(mm)
COMPACT 4-WAY CASSETTE Model Capacity KM12HK1DI KM18HK1DI Cooling Btu/h 12000 14400 22800 Heating Btu/h 13000 16000 27400 Ph,V,Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz m³/h 600/500/450 600/500/450 1180/950/850 CFM 353/294/265 353/294/265 694/559/500 dB(A) 44/41/38/34 47/45/41/35 47/45/41/36 mm 596×596×240 596×596×240 840×840×240 inch 30-5/8×30-5/8×11-3/4 23-1/2×23-1/2×9-1/2 33-1/8×33-1/8×9-1/2 mm 23-1/2×23-1/2×9-1/2 778×738×300 963×963×325 inch 778×7
[Light Commercial] U-MATCH DC INVERTER(REGULAR) Features: All DC inverter technology 43 Standard Easier maintenance Optional Intelligent defrosting High efficiency Quality motor Centralized control Modular operating Low temperature heating
It is a kind of split system that the outdoor unit can be freely connected to different types of indoor units according to various indoor decoration requirements. All DC inverter compressor and DC motor are adopted, so the energy efficiency of the unit is higher and the power consumption in standby is lower. Intelligent defrosting technology is applied.
Units Lineup Capacity Index(BTU/h) 18K 24K 30K 36K Outdoor Unit Duct Indoor Unit Cassette Floor Ceiling Gree reserves the right to modify the specifications without prior notice, please confirm the final specifications with the sales representatives.
Specifications Outdoor Unit Model KU21-ODU18-3 Indoor Unit Cooling Capacity Heating EER/COP Current Input 5000 5000 5000 17100 17100 17100 W 5500 5600 5400 Btu/h 18800 19100 18400 3.23/3.60 2.94/2.70 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz Cooling W 1550 1550 1700 Heating W 1650 1700 2000 Cooling A 7.93 7.93 8.70 Heating A 8.44 7.93 9.21 kg/oz 1.4/49.4 1.4/49.4 1.4/49.4 CFM 585 585 445 m³/h 1000 1000 760 Rated In.wg 0.1 0 0 Range In.wg 0-0.
Outdoor Unit Model KU21-ODU24-3 Indoor Unit Cooling Capacity Heating EER/COP Current Input 7000 7000 7000 23800 23800 23800 W 8000 8000 8000 Btu/h 27200 27200 27200 3.14/3.38 3.14/3.38 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz Cooling W 2230 2230 2230 Heating W 2360 2360 2360 Cooling A 11.41 11.41 11.41 Heating 12.07 12.07 12.07 2.2/77.6 2.2/77.6 2.2/77.6 CFM 820 705 765 m³/h 1400 1200 1300 0 In.wg 0.1 0.1 Range In.wg 0-0.
Outdoor Unit Model KU21-ODU30-3 Indoor Unit Cooling Capacity Heating EER/COP Current Input 8300 8300 8300 28200 28200 28200 W 9200 9200 9200 Btu/h 31200 31200 31200 3.07/3.54 3.07/3.41 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz Cooling W 3300 2700 2700 Heating W 3100 2600 2700 Cooling A 16.88 12.28 13.81 Heating 15.86 13.30 12.79 2.4/84.7 2.4/84.7 2.4/84.7 CFM 820 880 880 m³/h 1400 1500 1500 0 In.wg 0.15 0 Range In.wg 0-0.
Outdoor Unit Model KU21-ODU36-3 Duct(with/without water pump) Indoor Unit Cooling Capacity Heating EER/COP Power Supply Power Input Current Input 10000 10000 10000 34000 34000 34000 W 12000 12000 12000 Btu/h 41000 41000 41000 - 3.05/3.20 3.05/3.20 3.05/3.20 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 3280 3280 3280 Heating W 3750 3750 3750 Cooling A 16.78 16.78 16.78 Heating A 19.18 19.18 19.18 kg/oz 3.5/123.5 3.5/123.5 3.5/123.
Outdoor Unit Model KU21-ODU42-3 Indoor Unit Cooling Capacity Heating EER/COP Power Supply Power Input Current Input W 11500 11500 11500 Btu/h 39500 39500 39500 W 13000 13000 13000 Btu/h 44000 44000 44000 - 2.77/3.32 2.84/3.20 2.61/2.92 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 4150 4050 4400 Heating W 3900 4050 4450 Cooling A 21.23 20.72 22.51 Heating A 19.95 20.72 22.76 kg/oz 3.7/130.5 3.7/130.5 3.7/130.
Outdoor Unit Model KU21-ODU48-3 Duct(with/without water pump) Indoor Unit Cooling Capacity Heating EER/COP Power Supply Power Input Current Input 14000 14000 14000 48000 48000 48000 W 16000 16000 16000 Btu/h 54500 54500 54500 - 2.72/3.10 2.55/3.48 2.55/3.32 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 1Ph,208/230V,60Hz 5150 5500 5500 Heating W 5150 4600 5100 Cooling A 26.34 25.32 28.13 Heating A 26.34 23.53 24.55 kg/oz 4/141.1 4/141.1 4/141.
[Light Commercial] U-MATCH DC INVERTER(HIGH ESP) Features: All DC inverter technology Standard Easier maintenance Optional Intelligent defrosting High efficiency Quality motor Centralized control Modular operating Low temperature heating 52
Adopt all DC inverter compressor design to improve the energy efficiency of the unit; SEER and HSPE for the whole series is up to 16 and 19 respectively. The indoor unit adopts DC motor design, with a wide static pressure range. The nominal static pressure is 50Pa and the maximum static pressure is up to 200Pa. It can satisfy the requirements of long-distance air supply as well as multiple rooms' air supply. The whole series units have AHRI certificates and ETL safety certificates.
Units Lineup Capacity Index(BTU/h) 18K 24K - - 30K 36K 42K 48K Outdoor Unit Duct Indoor Unit Air Handler - Outdoor Unit Model KU21-ODU18-4 Indoor Unit Cooling Capacity Heating EER/COP Current Input Duct Duct Duct KU21-CDU18-4 KU21-CDU18-4S KU21-CDU24-4 KU21-CDU24-4S KU21-CDU30-4 KU21-CDU30-4S 5000 5000 7000 7000 8500 8500 17100 17100 23800 23800 29000 29000 W 5600 5600 8000 8000 9200 9200 Btu/h 19100 19100 27200 27200 31200 31200 3.23/3.50 3.23/3.50 3.
Outdoor Unit Model KU21-ODU36-4 Indoor Unit Cooling Capacity Heating EER/COP Power Supply Power Input Current Input Duct Duct KU21-CDU36-4 KU21-CDU36-4S KU21-ADU36-4 KU21-CDU42-4 KU21-CDU42-4S 12000 W 10000 10000 10000 12000 Btu/h 34000 34000 34000 41000 41000 W 12000 12000 12000 13800 13800 Btu/h 41000 41000 41000 47000 47000 - 2.78/3.53 2.78/3.53 2.94/3.43 3.00/3.21 3.00/3.
Control System Lineup Product series Duct Type Controlling System Cassette Type Floor Ceiling Type Air Handler YB1FA Remote Controller YV1FB7 YAM1F XK60 Wired Controller XK117 CE50-24/E Smart Zone Controller CE52-24/F(C) Note: ● standard optional Gree reserves the right to modify the specifications without prior notice, please confirm the final specifications with the sales representatives.
[Light Commercial] ULTRANIXX Self-diagn osis 57 Comprehensive protection High ESP Wide operation range Features: High efficiency Standard Intelligent defrosting Optional Energy saving function Inner groove copper
Universal Inverter Ducted Split System, with 24V control Ultranixx 18SEER 24V D.C inverter condensing unit, which is a newly designed and high efficient air conditioners, are targeted at the North America market and mainly applied to villas, office buildings, supermarkets, hotels, restaurants, etc. 2/3 Ton 4/5 Ton The outdoor unit adopts an inverter compressor, efficiency is up to 20SEER & 10.5HSPF. Adopt Gree two-stage compression EVI technology, small performance decline at extremely hot or cold area.
Specifications Condensing Unit Model Capacity Range Capacity KU60UHO*1*2 KU36UHO*2 Cooling Heating Power Supply Ton 2 3 4 5 Btu/h 24,000 36,000 48,000 54,000 Btu/h 24,000 36,000 48,000 54,000 V,Ph,Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 SEER - 20 18 17 17 EER - 11.5 11 10.5 10.5 HSPF - 10.5 10 10 10 MCA A 18 24 36 40 MOP A 20 35 45 50 12.3 Refrigerant Charge Volume Sound Pressure Level lbs 9.3 9.3 12.
Note: 60