Lubrication and Maintenance
ROW UNIT MOUNTED DISC FURROWER
Lubricate bushings in support arm mounting bracket at
frequency indicated in Lubrication of this section. Check each
bolt for proper torque. If bolt is loose, it should be removed and
bushing inspected for cracks and wear. Replace bushings as
necessary.
NOTE:Useonlyhardenedatwashers.Replacedamaged
atwasherswithproperpart.Torqueboltsto130ft-lb
(176.2 N-m).
Blade hubs are equipped with sealed bearings. Replace
bearings if a bearing sounds or feels rough when wheel is
rotated.
Row unit mounted disc furrower
Replace solid or notched 12" diameter blades when worn to 11".
ROW UNIT MOUNTED BED LEVELER
Lubricate bushings in mounting bracket and links at frequency
indicated in Lubrication of this section. Check each bolt for
proper torque. If bolt is loose, it should be removed and
bushing inspected for cracks and wear. Replace bushing if
necessary.
NOTE:Useonlyhardenedatwashers.Replacedamaged
atwasherswithproperpart.Torqueboltsto130ft-lb
(176.2 N-m).
Row unit mounted bed leveler
ROW UNIT MOUNTED NO TILL COULTER
Check nuts and hardware periodically for proper torque. Be sure
coulter is positioned square with row unit and aligned in front of
row unit disc opener.
NOTE: Torque " spindle hardware to 120 ft-lb (162 N-m).
Coulter blade can be adjusted to one of four settings. Initially
blade is set in highest position. As blade wears it can be adjusted
to one of three lower settings. See “Row Unit Mounted No Till
Coulter” in Row Unit Operation section of this manual.
Replace 16" diameter coulter blade when worn to 14½".
Row unit mounted no till coulter