Abso Sinewave Inverter-Charger 1000W (IC121040) 2000W (IC122055) Owner’s Manual
For safe and optimum performance, the Power Inverter-Charger must be used properly. Carefully read and follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING statements. PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide, KISAE Technology assumes no responsibility for errors or omissions.
Table of Contents 1. INTRODUCTION................................................................................................ 4 2. PRODUCT DESCRIPTION ............................................................................... 5 3. INSTALLATION ................................................................................................. 5 4. UNIT OPERATION............................................................................................. 8 5. TROUBLESHOOTING ..................
1. INTRODUCTION Thank you for purchasing the KISAE Abso Sinewave Inverter-Charger. With our state of the art, easy to use design, this product will offer you reliable service by providing AC power and 5V USB power for your home, cabin, boat, RV or Trailer and recharge your battery automatically when utility AC is available. The KISAE Abso Sinewave Inverter-Charger can run many AC-powered appliances when you need AC power anywhere. The 5V USB power can charge many USBpowered devices.
connected. • Consult the dealer or an experienced radio/TV technician for help. LIMITATIONS ON USE Do not use in connection with life support systems or other medical equipment or devices. 2. PRODUCT DESCRIPTION The KISAE Sinewave Inverter-Charger includes the items list below.
Preparing for Installation Typical Wiring block diagram of the Power Inverter: Output: AC Output Port 1-3 & USB Inverter-Charger Input: AC Source Branch Breaker DC Disconnect Switch Fuse or Circuit Breaker 12 V Battery Bank (IC121040, IC122055) 12V Battery Bank: • The use of deep cycle battery is highly recommended for power inverter application • For battery size, you need to identify what you wish to operate, and for how long. KISAE recommends that you purchase as much battery capacity as possible.
• Choose an appropriate mounting location. • For indoor use, the unit can be mounted in any direction except with the DC Input panel facing downwards. • Use the mounting template below to mark the positions of the mounting screws. • Drill the 4 mounting holes and place the Inverter-Charger in position and fasten the unit to the mounting surface. Chassis Grounding Connection: DANGER: The unit chassis has to be grounded properly. Never operate the InverterCharger without proper grounding.
and Output connection and that the DC disconnect switch is turned OFF. The AC Output connection has three types of configurations: 1) Use of the provided GFCI AC socket for AC load: This configuration does not require AC Output installation. Plug in the AC load to the provided GFCI output socket. During the by-pass mode, the AC output is limited to 15A for 1000W model (IC121040) and 20A for 2000W model (IC122055).
The unit is fully automatic. When utility power is available, the unit is running in AC bypass mode. AC output is supplied from the utility. The internal AC charger is ON and will automatically top up the battery bank that is connected to the unit. When there is a power failure from the utility or an AC source is not available, the unit will run on battery power and the unit will generate sinewave AC output to maintain and operate the load continuously.
E02 Input battery voltage is too high and unit has shutdown E03 AC output is overloaded or short circuited and unit has shutdown Internal temperature is too high and unit has shutdown E04 E05 E06 E07 E08 E09 E10 E11 E12 Input battery voltage is low and warning occurs AC output has sensed high and is close to shutdown limit Internal temperature is high and is close to shutdown limit Not used Not used Battery Charging voltage too high Battery bad Internal transfer switch temperature is high and shutdown
Understanding the Unit Settings Inverter Setting In0 In1 In2 5A – 40A 5A – 55A FLo GEL AG Fi SdL SdH Inverter is disabled, unit will not provide backup function when utility power is not available Inverter is set to standby mode with power save mode OFF. Unit will provide backup function when utility power is not available Inverter is set to standby mode with power save mode ON. Unit will provide backup function only when utility power is not available AND the load connected to the output is >10W.
>25Aac and <27Aac >20Aac and <25Aac <20Aac 10 Adc 20 Adc 40 Adc >21Aac and <26Aac >16Aac and <21Aac <16Aac 15 Adc 35 Adc 55 Adc Manufacturing Default Setting Fd Reset all settings to manufacturing default settings (40A for IC121040 or 55A for IC122055, In1, AL1, SdL, Flo, Cb3) Understanding the Charger De-rating Current: The charger current will be de-rated when the environment temperature reaches 60 °C (140 °F) or the internal temperature reaches the pre-set values.
Page 13
6. TROUBLESHOOTING To troubleshoot the unit, please note the error code displayed on the main unit and review “Understanding the Error Codes” in section 4. Problem No output voltage. And Status LED is off. Symptom The unit is off No AC output. Status LED is Green No Output.
Battery Type Charge Control Efficiency Safety and Environmental Conformance Gel, Flooded, AGM, Fixed Bulk/Absorption/Float >80% Conforms to UL 458 Certified to CSA C22.2 no. 107.1 cETLus 0°C to 40°C (32°F to 104°F) -20°C to 60°C (-4°F to 140°F) 5-90% noncondensing Up to 9,843ft (3000m) above sea level Agency Markings Operating Temperature Storage Temperature Relative Humidity Operating Altitude Weights and Dimensions Weights IC 121040: 12.5 lbs (5.7 kg) IC 122055: 14.5 lbs (6.6 kg) 9.0 x 18.8 x 4.