User's Manual

21 / 30
Kisan Telecom Confidential Proprietary
for download
MHU image download Downloads compressed firmware file to MHU equipment
RU image download Downloads compressed firmware file to RU equipment
Factory Setting Restores all parameter values to initial factory settings
System action Not available
Gain Setting
Tx: set ATT to have 30dBm on the remote ANT output.
Rx: set ATT to have 40dB of Rx total gain from RU to
MHU including optical loss.
Polling period Controls the polling period between PC and repeater
Block window Presents system window including MHU and RU
MHU Window Presents MHU status window in work space
View
RU Remote Window Presents RU status window in work space
Cascade
Tile Horizon
Cascade or tile horizon arrangement of repeater status
windows in work space
Arrange icons Arrange all icons under many window is opened
Close all Close all window
Window
Packet Debug
Presents debug window in workspace displaying packets
between repeater and GUI program
Help
About RptMan.Dual Displays the version information of GUI program, RptMan
(Repeater Manager)
6.7. Toolbar
ITEM ICON Function
Communication
Establishment
Establishes RS-232C connection to the repeater, then GUI
starts to communicate and status of repeater are polled and
displayed.
Communication
Disconnection
Disconnects communication with connected repeater.
Repeater status is not updated.
Polling
Stop/Resume
Stops or resumes polling action of GUI program. (activated
in toggling way)
Power Table
Presents RF/Optic power table
T/C table
Presents temperature compensation table
Debug Packet
Displays packet data between GUI and repeater like protocol
analyzer and it may help debugging of software
Compression of
image file
Compresses image file of repeater
Gain Setting
TX: set ATT to have 35dBm of output at the RU ANT Port
RX: set ATT to have 40dB gain of Rx path
Tx/Rx Gain setting function carry out Tx/Rx gain setting
including optical loss compensation automatically.