System configuration
MHU Capacity: 1 Optical Branch/DOU and 6 DOU/MHU (6 Optical Branch/MHU)
System Connection: Optic cable between MHU and RU
Optic Wavelength: 1310nm for FWD, 1550nm for RVS
Max loss of optic cable (between MHU and RU): 1 ~ 10dBo
3. System Specifications
3.1. General Specifications
Item PW1900-C MHU PW1900-C RU
Enclosure Type
7U-Shelf type
19” standard rack mountable
In-door use
Cabinet
W H D 19"(482.4) X 310(7U) X 450mm 450 X 630 X 355 mm Dimension
(mm)
Weight
15.5Kg 40.5Kg
Power Supply 110-120Vac (Tolerance ±10%), 60Hz 120Vac, 60Hz
Power Connector ID-NO3BEH MS3106A16-10S
RF In/Out Port SMA Female, rear side N Type Female, bottom
Optic Connector Type FC/APC, front side FC/APC, bottom
Optic Wavelength FWD: 1310nm / RVS: 1550nm
Operating Temperature -5℃ ~ 40℃ -5℃ ~ 50℃
Environmental requirement