Dimension Guide

30" (76.2 cm) and 36" (91.4 cm)
Gas Downdraft Cooktop
PRODUCT MODEL NUMBERS
KCGD500G
Type of Gas
Natural Gas:
This cooktop is factory set for use with Natural gas. If
converting to LP gas, see the “LP Gas Conversion” instructions
provided in the package containing literature. The model/serial/
rating plate located on bottom of the cooktop has information
on the types of gas that can be used. If the types of gas listed
do not include the type of gas available, check with the local
gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas
specified on the model/serial/rating plate for use with a different
gas without consulting the serving gas supplier. See the “Gas
Conversion” instructions provided in the package containing
literature.
Gas Supply Line
Provide a gas supply line of
3
4
" (1.9 cm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may
result in insufficient gas supply. Pipe-joint compounds
that resist the action of LP gas must be used. Do not use
TEFLON
®
† tape. With LP gas, piping or tubing size should
be
1
2
" minimum. Usually, LP gas suppliers determine the
size and materials used in the system.
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see
Installation Instructions packed with product. Specifications subject to
change without notice.
PRODUCT DIMENSIONS
Ref. W10848427B
01/2017
KCGD506G
GAS REQUIREMENTS
Flexible metal appliance connector:
If local codes permit, use a
1
2
" or
3
4
" I.D. flexible stainless
steel tubing gas connector, designed by CSA to connect
the cooktop to the rigid gas supply line.
A
1
2
" male pipe thread is needed for connection to the
female pipe threads of the inlet to the cooktop pressure
regulator.
Do not kink or damage the flexible metal tubing when
moving the cooktop.
Must include a shut-off valve:
The supply line must be equipped with a manual shut-off
valve. This valve should be located in the same room. It
must be accessible without removing the cooktop, and it
should be in a location that allows ease of opening and
closing. Do not block access to shut-off valve. The valve is
for turning on or shutting off gas to the cooktop.
A. Gas supply line
B. Shut-off valve open position
C. To cooktop
30" (76.2 cm) Cooktop 36" (91.4 cm) Cooktop
A. 21
1
/
2
" (54.6 cm)
B. 19
11
/
16
" (50.0 cm)
C. Model/serial/rating
plate location
A. 21
1
/
2
" (54.6 cm)
B. 19
11
/
16
" (50.0 cm)
C. Model/serial/rating
plate location
Page 1 of 2
B
A
C
B
C
A
B
C
A
GF
D
E
B
H
A
C
A 30" (76.2 cm)
B. 4" (10.2 cm)
C. 6
19
/
32
" (16.8 cm)
D. 18
7
/
16
" (46.8 cm)
E. 1
11
/
16
" (4.3 cm) recommended
minimum cabinet to motor clearance
F. 12
1
/
2
" (31.8 cm)
G. 14" (35.6 cm)
H. 28
1
/
4
" (71.4 cm)
GF
D
E
B
H
A
C
A. 36" (91.4 cm)
B. 4" (10.2 cm)
C. 6
19
/
32
" (16.8 cm)
D. 18
7
/
16
" (46.8 cm)
E. 10
3
/
8
" (26.4 cm) recommended
minimum cabinet to motor clearance
F. 12
1
/
2
" (31.8 cm)
G. 13" (33.0 cm)
H. 34
3
/
8
" (87.3 cm)